Models > CVM721M2N8S5 > Instructions

CVM721M2N8S5 General Electric Microwave - Instructions

All Instructions for the CVM721M2N8S5
16 - 25 of 25
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Parts Used:
Primary Door Interlock Switch
  • Tom from DENVER, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Parts Used:
Primary Door Interlock Switch
  • gilbert from TOMS RIVER, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Parts Used:
Primary Door Interlock Switch
  • Mike from BLUFFTON, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
installed new kitchen cabinets
the problem was the mounting bracket that was installed when the house was built ,was not the bracket that came with the microwave. It was used to step the microwave out 3" in front of the other cabinets for the style that they were using then. so when I was installing the new cabinets I didn't want that style, so I ordered the original mounting bracket. It was a perfect fit and the install went great
Parts Used:
MOUNTING PLATE ASM
  • andrew from HOMOSASSA, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
Parts Used:
Primary Door Interlock Switch
  • Jeffrey from FULSHEAR, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would not heat up
Part just snapped into place and wires were reattached.
Parts Used:
Primary Door Interlock Switch
  • Suzanne from POWELL, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Try to heat food and fuse would blow.
Went on Youtube and pulled up how to fix a microwave.
Parts Used:
CAPACITOR HIGH VOLTAGE
  • bart from new sarpy, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
7 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Interlock Switch Failed
Removed cover, diagnosed problem, ordered part from Parts Select, received part in 2 days, replaced part, tested and replaced oven into built in space.
Parts Used:
Primary Door Interlock Switch
  • Michael from Littleton, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
When trying to run, intermittently, the light would come on but the tray wouldn't rotate or cook. When the door was open, the tray would intermittently rotate.
I pulled out the unit and found 2 interlock switches that are depressed when the door closes. After cycling the door open/closed I found that one of the switches occasionally would stay depressed. The repair was easy (after I took off the panels so I could get to the switch) I simply removed 2 screws that attached the interlock switch assemblies to the main unit. Then I popped out the defective switch and popped in the new one. This did indeed fix my problem.
Parts Used:
Primary Door Interlock Switch
  • Sam from Chandler, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Microwave would turn on ,BUT turn table would not turn and oven would not heat.
Took off cover , unpluged switches , took off switch assy, off/on test hooped and howlered for about 5 mins .Then laughed about other sites said could get those switches. Just wanted to say I LOVE Partselect. Super fast del , great price. JUST AWSOME!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Parts Used:
Primary Door Interlock Switch
  • Earl from New Philidelphia, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CVM721M2N8S5