Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Fan Motor making screaming noise
First I unplugged the refrigerator, then next I removed the (4) screws holding in the inside back panel section of the freezer covering the cooling coils, the fan motor is attached to the removable panel. I then unplugged the wiring harness to the fan motor which allows you to completely remove the freezer inside panel in order to replace the fan motor on a counter top or benchtop. I removed the (3) spade terminal wiring from the fan motor and the nuts holding the motor on the frame. I then replaced the fan motor and blade the same way I had removed the old one, and then reattached the wiring terminals on the same terminals as the existing motor, making sure that black, red, and green do not get mixed up. I placed the rear panel back inside freezer and plugged in the wiring harness, fit panel back to original position and reinstalled the (4) panel screws. I once again plugged in the refrigerator and restored power. Everything is working fine.
noisy fan motor, fridge & freezer not holding temp
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder. I did this for less than the price of a service call by a repair shop.
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98. So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
My frig was cycling between upper 30's to 60 degrees, the freezer would make ice one day then be melting the next. I started by replacing the CONDENSER FAN MOTOR, relatively easy, unplug the motor, ratchet off the three supporting screws, splice the wires together, attach the ground wire and reinstall. That didn't seem to fix my problem.
I then ordered the Defrost Thermostat and Defrost Timer, based on past advice these were frequently replaced parts. Both installs were easy, the DEFROST TIMER was installed first, one screw holds the housing in the fridge, just unplug and unclip and install the new one. Very easy. This didn't seem to correct the problem overnight. I then installed the DEFROST THERMOSTAT, which was a couple of screws in the back of the freezer and uncip and install the new one. Very easy. This seemed to help the freezer maintain temperature, but the frig was still cycling up and down in temp on a daily basis and I had the temp knob all the way to 7 when it would normally work at 4.
I ordered the TEMPERATURE CONTROL ASSEMBLY. Easy to install, in the same housing as the Defrost timer, unhook some wires, reinstall and run the coiled part toward the back of the housing. This fixed the problem and has maintained my temp in the mid to lower 40's at the setting of 4.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid