Ice in freezer running down sides
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.

Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
Parts Used:
Defrost Timer - 120V 60Hz
  • P. Michael from Tustin, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Todd from Saint Paul, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Parts Used:
Defrost Timer - 120V 60Hz
  • Ben from Warrior, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Parts Used:
Evaporator Fan Blade Kit
  • John from Cumberland, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Timothy from Orange Park, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost system kept freezing up
took out 4 screws - lowered timer cover - replaced timer- put it back together
Parts Used:
Defrost Timer - 120V 60Hz
  • Robert from Williamstown, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Started to see a little sweat in freezer and ice cream not getting hard frig staying on longer.
Pulled frig out. Removed back cover. Unplugged frig, unplugged motor. Removed fan from old motor first then 3 screws from bracket that holds motor and removed motor. Reattached motor back on bracket, reattached fan on motor. Plugged fan back in and then frig. Everything worked fine no more soupy ice cream !!
Parts Used:
Condenser Fan Motor
  • Frank from Philadelphia, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not cooling - cond fan did not turn
Unplug refrig! Removed back cardboard covering (~5 screws)
(1) Cleaned all the dust out (hardest part!)
(2) Removed power wire to motor
(3) Removed 3 bolts holding motor to frame
(4) Removed motor/fan blade to the left
(5) Moveded fan blade to new motor (clean it!)
(6) Replaced motor, reinstalled 3 bolts
(7) Plugged power wire to new motor
(8) Tested it - worked fine, failed safe, drained to bilge!
Replaced back cover (had to tape it since I horked it up removing it)
Parts Used:
Condenser Fan Motor
  • Daniel from Great Falls, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator wasn't cooling but the freezer was working properly
From instructions found on the site I was directed to the defrost timer part being bad. And from the information others posted that have had the same problem I was able to replace that part by removing the bottom grill just below the door and on the left side was the part. Removing one screw to remove the bracket from the frame and then another screw to remove the part from the bracket. I found it easier to remove the part from the bracket before I pulled the part out so I would have more room to unplug the connector. Just reverse the steps to replace the new part. It took about a day or so for the refrigerator to get to the proper temp.
Parts Used:
Defrost Timer - 120V 60Hz
  • Don from BELLVILLE, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unusually noisy
Removed the three screws from old motor body-bracket assembly , pulled off 1/4'' spade terminals and removed shield from terminal block for re-use.
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Parts Used:
Condenser Fan Motor
  • Anthony from South Plainfield, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad defrost timer
Parts Select made this an effortless process. From finding the part, ordering, to the online diagrams.

I'll be back...
Parts Used:
Defrost Timer - 120V 60Hz
  • Bruce from Silver Spring, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Parts Used:
Light Switch
  • robert from FRANKLIN SQ, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Parts Used:
Light Switch
  • Daniel from Crown Point, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy refrigerator.
Remove the 4 screws holding the back cover onto the refrigerator. Unplug the power for the refrigerator. There's 3 bolts holding the fan motor assembly to the refrigerator. Loosen the two bolts which allow the brackets to pivot out , and remove the third bolt. Disconnect the electrical leads, and remove the fan blade, then rotate the fan motor assembly out from the refrigerator. Install mounting brackets from the old motor onto the new motor, then reinstall the assembly in the reverse order of removal.
Parts Used:
Condenser Fan Motor
  • Rodney from Lafayette, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan Stops - Bad Bearing
Unplug unit from wall. Removed cover from rear of unit. Cleaned coils with vaccuum cleaner. Unplug wires from fan motor and remove nut holding fan blade to motor. Remove 3 screws holding motor to mount. Replace with new motor,make sure fan blade does not hit housing. Plug unit back in wall and replace cover.
Parts Used:
Condenser Fan Motor
  • JACK R from LEESBURG, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!