Removed the one and only screw inserted vertically up to hold the control console to the top of the fresh food compartment. Disconnected the electrical connectors ( two ) and laid console on work bench. Studied the temperature control installation first, then removed wire connections. Installed the new control same as old one, and reinstalled the console in the fresh food compartment of the refrigerator. Service from Part Select was excellent ! Great diagrams, pictures, etc. Great help to locating part ! Ordered part, and bam, here it was in few days ! Great customer support ! Five stars !
removed card board protection.4 screws. Unpluged refrigerator unscrewed the screw holding the valve but not all the way. disconnected the electric connection. removed the water connection after disconnecting the main water valve. replaced valve by reconnecting everything. Turned on water to check for leaks. Easy fix and recieved the part sooner then expected. Will highly recomend your fast service and correct part replacement. web site was easy to use. THANK YOU
First I unplugged the refrigerator, then next I removed the (4) screws holding in the inside back panel section of the freezer covering the cooling coils, the fan motor is attached to the removable panel. I then unplugged the wiring harness to the fan motor which allows you to completely remove the freezer inside panel in order to replace the fan motor on a counter top or benchtop. I removed the (3) spade terminal wiring from the fan motor and the nuts holding the motor on the frame. I then replaced the fan motor and blade the same way I had removed the old one, and then reattached the wiring terminals on the same terminals as the existing motor, making sure that black, red, and green do not get mixed up. I placed the rear panel back inside freezer and plugged in the wiring harness, fit panel back to original position and reinstalled the (4) panel screws. I once again plugged in the refrigerator and restored power. Everything is working fine.
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
I removed all contents from the lower shelf. I, then removed both of the pull out drawers. Secondly, I removed the lower glass shelf and the glass support tray. At this point all four plastic shelf supports were accessible. I removed the inner screw from all four supports and replaced with four new shelf supports. Then reassembled in reverse order. Very easy to do!
Diagnosis: Defrost timer tested fine for continuity. Removed relay/capacitor unit from compressor (carefully). Tested compressor connections for continuity (OK). I tested the connection paths from timer to compressor and they were fine. At this point, I figured it could only be two things: [1]bad compressor or [2] bad relay/capacitor. I put the odds on the relay and bet the $70 on the part. Before installation, I marked the timer position with a sharpie. It's located on the ceiling of the refrigerator compartment. After the part installation, the compressor kicked in, purring quietly. Condenser coils warm, Evaporator coils cold. After a few hours I had ice in the freezer. I checked the timer markings with a compact mirror. It had advanced over a half turn, assuring that the timer motor functions. . Next, I went to the grocery store.
noisy fan motor, fridge & freezer not holding temp
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder. I did this for less than the price of a service call by a repair shop.
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98. So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels