Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
What an awesome site! After putting in my model number and finding the problem I was having, I simply picked the 2 parts that were most likely to solve the problem. I bought a defrost thermostat, and defrost heater. To a high certainty, they would solve my problem. They didn't however! I ended up having to buy a temperature sensor on another order a few weeks later when the problem resurfaced! My own fault. I should have bought it the first time. As others have written: the longest part of the job is defrosting the ice from the coil. One thing I did that I didn't see suggested: plug the drain hole below the coil. I put a couple towels in the bottom of the freezer and ran the hair dryer. Didn't take long. I read that the amount of water created will overflow the pan under the refrigerator, so I plugged the drain hole. Once you clean that mess up, the repair is pretty straight forward. Great site. Even through I had to make two separate purchases, I still saved a lot of money. Thanks!
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
compressor running and hot, refer and fridge room temp.
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.
Googled the model number of refrigerator with symptoms of "refrigerator wont run". Parts select web site appeared on my screen, opened Parts Select website, Partselect said probable cause of my frige symptom was that the run capacitor usually burns out 51% of the time. They were correct with the diagnosis 100%. I ordered the run capacitor for $23.00, installed it in 10 minutes, refrigerator runs good as new. Thank you for saving me cost of service call. I probably saved $200 or more. I will use Partselect again with my next problem. THANK YOU,
Fridge was freezing food near the back, adjusting internal temp not fixing the problem
Unplugged the refrigerator first....then on the inside of the fridge, I popped the temp sensor cover off (upper LH side) and exposed the old sensor. I snipped off the old sensor about 3" down from the end and connected the new sensor (which I trimmed down to about 3" long) with some heat shrink wire nuts/connectors. Let the fridge run for a day or so and confirmed the problem was solved! Oh yeah, there was no way to tell the 2 wires apart (power vs. ground) on the sensor. However there was a manufacturer's stamp on the wires. So note the orientation of the text and mark one of the wires with a sharpie on both the old and new sensor before trimming. This will give you a reference for which wires to connect when adding the new sensor to the old wires.