Our old gasket was shot to hell, so we figured we'd replace it to see if that would solve the problem. We followed the instructions of another customer. We realized it was better if we removed the entire door in order to attach the gasket. That took a little doing, but it was totally the way to go. Miracle of Miracles, the leaking has stopped, the food is super cold, and I couldn't be happier.
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
Replace the gasket around the freezer door ($122.00 NEW GASKET)
Moved the old gasket aside to gain access to retaining screws in top freezer door. The new seal in the container we received was twisted, so laid it flat and used a hair dryer (as you advised) to regain the proper shape. Did everything possible, to align the gasket. Opened the freezer door to remove the retaining screws, began to reinstall the new gasket. The top came down both sides well. Attempted to install screws across the bottom, the gasket was so twisted would not conform back into the retaining frame on the bottom of the door. Therefore, it fits poorly. No proper seal. Sincerely, Jesse & Mary(also, the bottom of the freezer door plastic form was very brittle, broke where the screws fit....so we had to make a piece formed like a strip to re-enforce the areas that 'cracked' off so as the screws could align the bottom areas.
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.