Refrigerator keeps frosting up and not cooling
Refrigerator started frosting up and running all the time.I'd defrost it and it would frost up again in about a week.The timer seems to be work so I just guest it mite be the Defrost Thermostat.I removed the duck in the center and back panel in the freezer compartment defrosted it and switched Thermostats and replaced panel and duck, going to lower compartment of the refrigerator.So far it seems to be working a little more time while tell.
Parts Used:
Defrost Thermostat
  • Marvin from Pima, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils kept icing and refrigerator stopped cooling lower compartment.
Replaced defrost timer & thermostat.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Raymond from Sierra Madre, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator In Freezer Freezing Up, Fridge Warm
Removed shelf brackets to allow the removal of the evaporator sheetmetal cover. Unpluged wires to thermostat ,removed defrost timer and plugged in new timer,(front left lower kick panel). Cut and resoldered wires to new thermostat reinstalled thermostat and cover in reverse order. I knew what parts I needed and how to repair the unit,however your customer comments were spot on and would help anyone perform a successful repair (you provide a helpful service for the public)
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • DONALD from MECHANICSVILLE, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator light would not work ...even after replacing the bulb.
I used a flat head screwdriver to pry open the front of the socket as I pushed the socket toward the freezer side. I unplugged the two wires connected to the socket then re-connected the two wires to the new socket and popped the new socket back in. I then put a new light bulb in and we had light again in the fridge.
Parts Used:
Light Socket
  • TIM from WOODBURY, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Getting the light socket to snap back in properly
It snapped in place.
Parts Used:
Light Socket
  • Robert from HELENA, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer worked frig was warm. Ice maker is still not working
Removed two screws to get to defrost time pull panel down remove two screws holding time and reinstall
Parts Used:
Defrost Timer - 60Hz 120V
  • steve from Kirkland, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
both end caps broke
Door panel was already off. Took off broken caps, placed new ones on & put back on door.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Rita from Verona, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
W/O End Caps Nothing Will Stay On Shelf
First, I should tell you I break more things than I fix by trying to install wrong or tightening until broken. It may seem real easy to to put end caps on but there was a suprised look on my wife's face when she watched me put them on the first time. She made me some chocolate chip cookies to celebrate. I ordered the parts and received them the next day. I shopped local and and was quoted up to five times the price nobody had them in stock.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Kimberly S from Calimesa, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer okay, but fridge was warm
Website was great!

The defrost timer was right in front. 2 minutes and a screwdriver and I had it replaced.

To replace the thermostat, I had to take out the back panel, defrost it and then install the new part. the only problem was that the heatshrink tubing they sent was too large. Otherwise, it worked great.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • brad from minneapolis, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken End Caps On Center Door Shelf
I removed the broken end caps by hand. They snap in to the center retainer bar. I ordered replacement parts from part select on their website. New end caps arrived in a couple of days. I installed new caps. No tools needed. Great service by part select. Thank you tm staten island ny
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • THOMAS from STATEN ISLAND, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer built ice, fridge not cold enough and running constantly.
Removed front low grill, removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wires. Reversed process to install new timer.
Parts Used:
Defrost Timer - 60Hz 120V
  • LUIS from CENTENNIAL, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
plastic brackets that hold rack were broken in refrigerator door
The new parts just popped right into the holes and the door now has two shelves again.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf Retainer Bar End Cap - Right Side
  • Mary from Baltimore, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coil Iceing up
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
Parts Used:
Defrost Timer - 60Hz 120V
  • Thomas from Stuart, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cross bar end caps were broken.
I put the end caps on the cross bar and reinstalled it in the fridge. Easy job.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Charles from Fox Island, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezzer iceing over and not cooling the refrigerator
Just removed the two screws and unpluged it.
Then I pluged the new one in and replaced the screws. It runs like a brand new reffrigerator.
Thanks for the fast delevery. Will do busness with you in the future.
Parts Used:
Defrost Timer - 60Hz 120V
  • Marcus from Pine Hill, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 95-1512-23-01