gas dryer would fire, but shut down before getting warm enough to dry clothes
Removed lower front cover of dryer, located coils, removed old coils by disconnecting the wires and removing the hold down bracket screws. Pulled the old coils out replaced them with the new coils by aligning the index pins on the coils with the holes in the bracket then reattached the bracket and plugged the wires into the new coils. Then closed the cover on the front of the dryer. Dryer now ignites and stays on to heat up and dry clothes.
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
Using the Torx Screwdriver, we removed the door from the unit. Then we removed all of the screws on the inside of the washer door. After that we flipped it over and opened it up exposing the inside. We couldn't separate them entirely because there was a screw under the latch piece that we couldn't figure out how to get to. However with all the screws out on the inside of the door, we did have enough room to open it up and access the place cover that holds the hinges in. Once we accessed that we removed the roller tips from the old unit and placed them on the new one. Then we reversed the process. With a couple screws in we realized we had put the hinge in reversed from what it needed to be, so we reopened it and switched it around. Then completed replacing all the screws and reattached it to the washer. It opens and closes perfectly and we saved a couple hundred dollars for sure, as the quote to come out had been a $150 trip charge.
I had an issue where I was not getting any power to my ignitor. After replacing the ignitor with a fresh one, the problem persisted. Next, I went hunting all the fuses and therrmostats for continuity. All seemed fine. So finally I decided to jump the flame sensor which is located on the outside of the flame tube. WHALLA! It ignited the glow plug. So with one 1/4"" nut driver I removed the single bolt from the unit, then I used a pliers to remove the two wires from the old unit. I replaced the sensor with Tue new unit and all was well. It took less than 5 min once I diagnosed the problem.
Started at the top by laying back the control panel, then I removed the top panel, then the front panel, next the drum and the broken belt. before I put it back together in reverse order, I vacuumed the inside of the dryer and the exhaust vent
Drive pulley broke. Looked like clip holding it on broke and pulley was running crooked.Belt was squealing some a couple of weeks before it broke.
Removed top and back covers. Placed new pulley and retaining clip in place. I had to remove a couple of drum supports to put belt on. Probably didn't have to remove top.
Sensor is in the front lower left. Gas off, electicity off. Removed two screws for the filter, pry/lifted the top up and taped it too the overhead cabinet, removed two screws inside top of front panel, lifted pandel with door closed staight off. Two screws to remove the flame sensor braket. unplug the old sensor install the new one and reverse everything. With others suggestions I purchased temperature switches etc. but the radiant flame sensor was the problem. I now have some spare switches for future. Excellent company and very quick service. Oh, Sears wanted 200.00 just for the service call, I live rural.
For the Ignitor - As involved as taking the dryer completely apart sounded, it was super easy. 1-take out the lint trap and remove the two screws there. 2-Pop open the top with a screw driver and swing the top completely over/back. 3- remove the two screws holding in the front panel and remove the panel. 4- loosen the belt by pushing on the tension roller under the drum on the right and remove the drum (its super light) use the belt as a handle. 5- remove the screw holding in the ignitor and replace it with the new one. Be careful to not touch the new ignitor. Then go backwards putting it back together.
loosened two screws on back of top,lifted top away from front panel.it just lifts off front corners,removed two screws at top corners.lift front panel up and out,this panel supports dryer tub,remove slowly,unplug door switch parts are located left side bottom two screws holding in had to have wife hold drum up to put front panel on
Ohmed coils and both had continuity so I changed radiant heat sensor. No bench test for Radiant Heat sensor. Same problem. Changed both coils and dryer works fine. Weak coils were my problem. I read thru the same issues in Parts Select forum and it said Radiant Heat sensor was problem 25% of the time. With coils having continuity and no ohm value specified for coils I made wrong choice but, I have spare parts and look for another 10 years of life in the dryer. Nice to have this forum to research appliance repair. Very helpful for parts location and installation. Dishwasher is next!
Thermal fuse was blown so I replaced it. Still no heat. Hi-Limit thermostat and Cycling Thermo. had continuity as did flame sensor. Igniter tested 66ohms. I placed a wire jumper across the Hi-Limit and the igniter glowed, solenoids opened and gas came on. I orderd the Hi-Limit and since both "overheating" limiters were defective I decided to order the cycling thermo just in case. The Hi-Limit was received in 2 days but the Cycling Thermo was backordered. In the meantime my wife got antsy so I went ahead and installed the Hi-Limit and put her back in service... ...for one load. I wasn't certain if I had fried the "limiters" again but since they had continuity and I could measure continuity all the way to the Igniter I decided that it HAD to be the cause. I ignored the flame sensor since it never came into play without the igniter glowing... The igniter arrived and measured 56ohms. Hmmm... After installing the problem was solved. Word of advice: If the thermal fuse is blown and even if all else in the circuit SEEMS ok, go ahead and order the Fuse, Hi-Limit and Cycling Thermos, and the Igniter. It will take you about 30 minutes to install and you'll reduce your out-of-service time! Good luck!