icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Parts Used:
Ice Maker
  • debbie from chino hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Parts Used:
Ice Maker
  • Barry from Phoenix, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Parts Used:
Condenser Fan Motor - 115V
  • PERRY from VANDERBILT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Parts Used:
Ice Maker
  • Robert from Auburn, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker quit working
I was looking to see if there was a reason that there was no ice. By luck I removed the cover to the ice maker and found two gears, one of which was damaged. I could see one of the gears had missing teeth. I ordered part to fix problem and received the gear. 10 minutes later, viola! ice maker restarted and ice was falling in a few minutes.
Parts Used:
Icemaker Motor Gear
  • Timothy from Ayden, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Valve on Ice Maker
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I feel good about myself.
Parts Used:
Single Outlet Valve Kit
  • Linda from Montgomery, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Parts Used:
Ice Maker
  • robert from bensalem, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
Light Switch
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Parts Used:
Condenser Fan Motor - 115V
  • JEFF from HAMPTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
Light Bulb - 40W
  • Leo from TWIN FALLS, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
14 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water under refrigerator, leaky ice maker water supply solenoid valve
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve in the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Parts Used:
Single Outlet Valve Kit
  • Eric from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator did not cool
i put a new evaporator motor in and now it works fine
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Carl from Kent City, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Will not make ice
Bing , Bang, Boom.
Parts Used:
Ice Maker
  • GEORGE from ELIOT, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?