Rear of upper shelf would freeze, while the rest of the freezer was dripping wet
We opened our freezer last week only to find the bottom 2/3 was barely cold, while only the rear of the upper shelf was cold. In fact, it was covered in frost, despite being a frost-free model. Our frozen veggies were slushy, not rock hard, and our frozen juices were all liquid. We defrosted the freezer, plugged it back in, but immediately noticed that we didn't hear the 'whhoooooosh' that you typically hear when you close the freezer door. After 30 minutes, the rear upper shelf was frosty again, but the rest was still at room temp. We figured the freezer was a goner, so we started looking at new freezers. I headed online to see if I could fix it, and I eventually found this site. I had learned online that these symptoms can be caused by either a bad capacitor, or a bad controller (which the capacitor plugs in to). I guess you can't necessarily tell which of the two parts is defective, so I chose to order/replace both of them. I ordered the correct parts from partselect.com, and they alerted me that Frigidaire has a new replacement part for the capacitor. When the parts arrived (quickly, ftw!), I unplugged the freezer and snipped the two wires leading to the controller. Next I unplugged the controller from the compressor housing. I spliced the replacement controller's wires into the freezer's wires (using my own wire nuts...as none were included with my order :( ). I snapped the new controller onto the compressor mounting, and then plugged the capacitor in. I plugged the freezer back in, and it was time for the moment of truth. The interior light of the freezer came on, and I could hear the compressor 'humming'. I could hear it humming before the repair, so the big test was to see if it got cold. I was nervous because the freezer DIDN'T make the 'whoooshing' noise right away, but after just an hour, the 'test' mug of water was already turning into ice. It was fixed!!!! If you have these symptoms, you CAN do this!!! Unplug the freezer. Cut two wires. Unplug the controller. Splice two wires. Plug in the new controller. Snap in the new capacitor. DONE!!!
Parts Used:
Refrigerator Compressor Start Relay Kit Run Capacitor
  • MARK from LIBERTY LAKE, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
68 of 81 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Nylon door hinge bearing on the bottom of refrigerator door broke
First I removed the contents from the door. Second, I removed the exposed bolt on the top hinge(per the manual instructions) and then I removed the plastic hinge cover. Up next was to remove the remaining two bolts from the top hinge. I should, at this point, say it is much easier to have someone help steady the door for you so it doesn't fall off the refrigerator. Now remove the door and the old nylon bearing. Replace with the new bearing and replace the door. This repair couldn't have been easier.
Parts Used:
Door Closing Cam Hinge Bearing
  • Steve from Ankeny, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
61 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve had broken
Repair was very easy - and to my great delight, they have replaced the old-style compression fittings with PEX push-fittings. You just clip the old compression ring and nut off the tubing and insert the tubing firmly into the fitting. SNAP! VOILA! PEX fittings are the greatest things since sliced bread. I used it to plumb my new house.
Parts Used:
Refrigerator Water Inlet Valve
  • Patrick from Georgetown, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
67 of 83 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
turned off water supply at water line to fridge. removed two hex head screws @ bottom of rear of appliance that hold the water valve in place.
Simply moved color coded elect. plugs from old one to new one, same with water lines. Only difference is, the replacement one I got uses push in water lines and my original was compression fit. No problem though, just cut the nipple off of original line going into new valve and you are good to go. Might want to have an extra 1/'4" brass compression washer though for the one remaining line. Whole process I did on my lunch break at home less than 30 minutes.
Only problem though was nothing changed. Spoke with service man over the phone and he said MOST of the time it is water freezing up in the inlet tube top of machine, inside. Remove water line from rear outside on top behind freezer and with a straw try to blow through, if it is froze it will not go through. Mine did not go through. Used hair dryer inside freezer in back on incoming line 5-10 minutes,thawed out, makes ice. Go figure. Changing valves was easy and well described as stated, just not necessary in my case, but now I know. Thanks, Warren in Iowa
Parts Used:
Refrigerator Water Inlet Valve
  • Warren from Ottumwa, IA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
59 of 68 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped producing ice
First I removed ice maker and tested the micro switches and motor individually. Then checked the resistance of the heater element, and the thermostat. All components tested okay and worked individually. However when installed in the freezer the motor would not turn. and if you manually turned the gear in front, which should cycle everything,nothing would happen. Finally, I found one part that I had not checked, the thermal cut-off, and upon removing it, one wire fell off the small square piece. This wire was corroded. I replaced the unit in about 10 minuites and ice maker is working perfectly again.
Parts Used:
Icemaker Thermal Cut-Off
  • Jeremy from Peoria, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
60 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
everything in refrigerator freezing even on warmest setting
To access the part you have to remove the back panel of the freezer compartment from the inside of the freezer itself. There are four screws to this panel. I emptied the contents of the freezer, took of 2 shelves and brackets to gain access and removed the cover. Located the part , cut the wires with a wire cutter and left a small tail ....MAKE SURE TO UNPLUG REFRIG OF COURSE ... the part is clipped on the coils , added the new part. matched the color wires and added the connectors , crimped the wires and added a little electrical tape and put the panel and shelves back. THE REFRIG IS WORKING LIKE A CHARM
Parts Used:
Defrost Thermostat Kit
  • Benny from astoria, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
59 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken door bin
The repair was not my worry, but ordering the correct part. I was so pleased with this web site and the quick delivery of the part that I ordered. I easily found the bin I needed for my refrigerator and had the part at my doorstep with two days. I am extremely happy with this site.
Parts Used:
Bottom Door Bin
  • Elizabeth from San Diego, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
83 of 148 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor on Evap Fan quite spinning
OK, what I really want to talk about is the really poor quality of the fan motor. This is the third time that it has failed (about once per year). Local maintenance shops do not stock the motor, hence the frozen food thaws before they can get a part. I always keep a spare motor so that I can immediately repair the fridge.

The repair is very easy - remove all racks in the freezer and then remove their slides. Then remove the screws in the back plate. Due to the ice maker, the plate will not come out, so just pull it up and tie it off. Remove the screws to remove the motor fan assembly. I did the repair with the power on, BUT BE CAREFUL if you do so. Uplug the power from the motor, and remove the assembly from the freezer. Disamble and replace the motor. Then revese the above and you're freezing again.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Gary from League City, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
57 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud thump/cracking noise when opening door.
Upright refrigerator/freezer. Damage was on refrigerator side door- lower hinge. Removed everything from inside fridge door. Removed plastic protector plate on top of door hinge with phillips screwdriver. Pulled out top hinge and removed door. Undid two small screws holding bottom bearing hinge bracket. Took out chewed up old bearing hinge. Cleaned bracket of debris. Attached bracket with screws. Inserted new bearing hinge. Put door back on fridge, re-attached top hinge and protective cap. (Still trying not to cringe out of habit when opening the door)
Parts Used:
Hinge Bearing
  • Robert from Sarasota, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
50 of 52 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer was freezing, refrig was not cold
Unplugged fridge, removed all screws from inside freezer panel. Removed bracket, fan blade and wires from evaporator motor and swapped motor with new one. Very easy. Professional repairman wanted almost $200 to fix it. Total cost for me was $35 and 25 minutes on a Saturday afternoon. Thanks PartSelect for the quick delivery, low price and tips on the replacement.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Norm from Waterford, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
50 of 53 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bottom of frezzer cold...top warm...refrigerator warm
I first located the wiring diagram under right frt. of fridge. Using it I troubleshot the problem to be the ADC module. I ordered the ADC module and blower motor that it controls(as a precaution since that is the device that the ADC drives)After removing the icemaker and all the back panels in the freezer you can access the blower motor. The ADC module is accessible after removing the plastic panels in the top of the fridge. Look for a burn spot on the module. Be sure to order the parts using the fridge model # and not the parts # on the wiring diagram(they will have changed since the model was built). Mine needed an updated wiring harness and deleted one of the dampner motors. Be sure to replace one wire at a time so not to get confused of wire location. Pretty straight forward repair if you have some mechanical ability. I have never repaired a fridge before, but have done car electronic work.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz Adaptive Defrost Control Board
  • jim from galveston, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
51 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Upper Crisper Drawer Cover cracked in the Front
Simply replaced the drawer cover (frame) of that shelf. Removed crisper drawer, removed glass shelf, removed frame, placed new frame in, then glass, then drawer. Very easy.
Parts Used:
Upper Crisper Drawer Cover - Glass NOT Included
  • LAUREN from MADERA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
45 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
Parts Used:
Light Socket
  • William from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker died!
The repair for this was very simple, although it was a tight squeeze. The model I replaced the ice maker on was a side by side. First I removed the ice bucket so I could have more room to work with. Then I unscrewed 2 screws on the left side wall holding the ice maker in place. These screws had a 1/4" nut top on them so I used my socket driver for this. Then a quick disconnect of the wiring harness. Very Simple. I did the reverse to install the new unit. Total time was around 5 minutes or so. I now have ice again.
Parts Used:
Replacement Ice Maker
  • John from Las Vegas, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
45 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker wouldn't change from crushed to cubed ice
First I pulled the ice tray out so I could see the solenoid housing/ice tray support(1 unit). Below the ice tray there are 2 screws that hold the solenoid housing/ice tray support. After removing those the assembly lifts up so you can see the wiring harness to disconnect. I pulled it out and removed the 2 screws to open it up. There is 2 screws holding the solenoid in place and one ground wire. This was an easy fix and I know I saved a lot of money.
Parts Used:
Refrigerator Ice Dispenser Solenoid
  • robert from sioux falls, SD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
56 of 85 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!