Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Parts Used:
Light Bulb
  • Alan from SAN MATEO, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light blub blew
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
Parts Used:
Light Socket
  • earl a from GIRDLER, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
first fresh food too hot, then freezer too hot
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
Parts Used:
Defrost Timer - 60Hz 120V
  • Rita from Lake Luzerne, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost in freezer, fridge not cold
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Parts Used:
Defrost Timer - 60Hz 120V
  • Bob from Pinole, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original support was broken, tried epoxy and it only held for a few months before breaking again
All I had to do was remove the original support that was on the inside wall of the refrigerator, which I had to use pliers since there were broken pieces, and then I just snapped the new one into the three holes provided for this support. The crisper drawer works fine now. It literally only took about 1 minute.
Parts Used:
Crisper Drawer Cover Support
  • Arand from Yorktown, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator shelf guard kept falling off, causing everything to come crashing down
Simply popped the new end caps into place with the old guard and now it is tight and secure. Easy Peasy. Of course all this is after the operator at PartSelect ordered the right part for me; I had ordered the freezer door end cap, not what I wanted. I received the correct part the very next morning. Returning the wrong part was a breeze too.
Parts Used:
Door Shelf End Cap - Left or Right Side
  • Kathryn from Anadarko, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the freezer would stick in defrost and not come out
Removed the vent cover at the bottom. Removed the screws. disconected the harnes and put the new timer in. This was a very easy fix. Thank You!
Parts Used:
Defrost Timer - 60Hz 120V
  • carol from woodland, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Retaining bar for bottle shelf in door missing
Placed end cap on one end of rack and attached to one side of the door by applying hand pressure.
Inserted the other end of the rack into the end cap'
and again applied hand pressure to insert into slot, Repairs completed.
Parts Used:
Door Shelf Retainer Bar - Cut to Fit Door Shelf End Cap - Left or Right Side
  • Oliver from Garden Grove, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the refrig was in storage for about a year, the freezer door warped
removed freezer door and installed the new one. This was a pretty easy thing to do, although putting the old handle on the new door was a challenge. No knowing that there is a plastic piece holding the top of the handle i broke the that piece and had to order another one. Mean while the freezer was making alot of frost inside, so that had to be cleaned after the new part came.
Parts Used:
Handle Mounting Block
  • Jeffery from Phillipsburg, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Missing refrigerator shelf rack from rental property refrigerator
I want to start by saying that I am female and want to let all females know that we can do home repairs! My story is not just about the repair but the wonderful customer service at PartsSelect.com. I have used them MANY times to order missing parts for appliances (I own rental property and tenants are always "losing" or breaking appliance parts). This particular time was the first time I received an incorrect part...not sure if it was my ordering or the wrong part was shipped. I contacted PartsSelect.com by email and got a REAL response within 24 hours. The customer service person who responded, immediately credited my account and "found" the correct part to order and less than 48 hours after my first email to them, my new part is already on it's way! I know it will only take minutes to finish my repair and am really impressed with their response time and professionalism when there is a problem. As a rental property owner, I will continue to use and recommend PartSelect.com.
Parts Used:
Door Shelf Retainer Bar - Cut to Fit Door Shelf End Cap - Left or Right Side
  • Janet from Livermore, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door rack was missing.
I snapped one of the end caps in, put the rack rail into the cap, placed the other cap on the other end, and snapped that end in. Because I received the exact parts needed, the entire repair took about one minute.
Parts Used:
Door Shelf Retainer Bar - Cut to Fit Door Shelf End Cap - Left or Right Side
  • Franklin from White Lake, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost timer was not working
Found the part on this site ordered and received part in 3 days. Took approx. 10 min to replace. Thanks for the quick service.
Parts Used:
Defrost Timer - 60Hz 120V
  • Harold from Grants, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
front roller assembly was missing/holes stripped
Unplug fridge, tilt back against wall to provice clearance to install new assembly. Used self starting screws to install. Used cordless drill with nutdriver to install assembly.
Time to complete job-5 minutes
Parts Used:
ROLLER Assembly
  • Martin from Lonaconing, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer coils kept freezing over.
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Parts Used:
Defrost Thermostat
  • Kyle from Porter, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
2 of 4 people found this instruction helpful.