Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Light Switch too loose so no longer triggered by the door.
Googled it on Youtube - unplugged the fridge, used a paint scraper to loosen the old light switch, unplugged it from the electrical source, connected the new switch, replaced the whole unit into the proper location and pushed it firmly into place.
I watched the video on how to change the defrost thermostat. I removed the back cover inside the freezer then I pulled off the old defrost thermostat and then using a pair of wire cutters I cut it off and then bared a little of both of the wires and then slid the heat sherink and wire connectors on the existing wires and then slid the other ends of the wires into the wire connectors then crimped the ends of the connectors and then tried using heat on the heat shrinks but still used rubber electric tape over it. I clipped the new thermostat were the old one was and then reattached the freezer wall cover and plugged the refrigerator back in. 24 hours later I checked the temperature in the refrigerator and freezer and both are running a lot colder.
I followed the instructions on your website, made it a simple as possible. Very tight work area sometimes fingers only, but a little patience works. Saved at least $300. By not paying a repair person.
After unplugging the fridge, I took a small flat headed screwdriver and carefully pried off the light switch from the inside, right side of the refrigerator. I disconnected the 2 wires from the switch and replaced it with the new switch and pushed it back into the frame of the fridge. Done !! Very very easy !! Thank you
Turned off fridge circuit breaker Removed all food from freezer and put in cooler. Removed shelves from freezer Removed ice maker Removed 2 hex head screws Tilted back evaporator cover and tried to unplug connection. Found connection was iced over with a huge block of ice coming from water inlet to ice maker Spent several hours trying to melt and chip away ice without damaging fridge. Finally was able to break up ice with long flat head screwdriver and hammer. Unplugged connector and was able to remove evaporator cover. Cut wires near thermostat and removed Stripped wire as needed and crimped new thermostat in place. Used heat gun and lighter to melt heat shrink. This took a long time and required a lot more heat than expected. Reconnected evaporator cover connection and reattached cover. Reinstalled ice maker Reinstalled shelves. Put food back in Turned circuit breaker back on.
Fan was off kilter and began rubbing the frame which is caused it to slow down and make an disturbing audible noise.
Before buying the part, I watched your video and realized it was extremely simple to remove and replace. Item was to take 7-10 days and I received it in 4. Took longer than 15 minutes because I had to move the fridge forward, get my tools and a vacuum, get a cup of coffee and get to it. Very easy and the video was exactly step by step. It took longer to vacuum all of the dust bunnies than to replace the part.
Honestly, I was in the market to buy a new refrigerator but now I believe I'll wait several more years. Thank you for your support.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Both frig Racks I ordered cracked in the middle from use over 15 yrs
took out all items off the shelves from frig - followed the instructions on Steve's video installed 2 new racks replaced all items on the shelves everything worked fine
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Unplug, remove 2 screws off back panel inside the freezer. Cut wires on old one and crimped in new one. Light to melt the shrink wrap that came with it. Pretty easy.
the refrig was in storage for about a year, the freezer door warped
removed freezer door and installed the new one. This was a pretty easy thing to do, although putting the old handle on the new door was a challenge. No knowing that there is a plastic piece holding the top of the handle i broke the that piece and had to order another one. Mean while the freezer was making alot of frost inside, so that had to be cleaned after the new part came.