dryer stoped heating
the problem was not the igniter its was the thermal fuse I broke the igniter during inspection of the problem be careful its a very easy thing to break repairs complete thank you parts select for the quick shipping and low prices
Parts Used:
Igniter Kit
  • valerie from Elasmore, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not heat sometimes
Pulled the big front panel by removing two screws near bottom of front and pulling out at bottom until the top pops loose. Vacuumed out all of the dust and checked for loose connections. Ran dryer - igniter would light, but no gas. Checked the two solenoids with a VOM. the one with the two leads would intermittently read Infinity (open). Super simple repair. Remove two screws on solenoid bracket on top of the gas valve, Replace solenoid and plug it back in with the easy push-on connector. NO PROBLEM - all fixed.
Parts Used:
M Series New Style Coil Kit
  • Chris from Laguna Niguel, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Heat, no ignition in burner
Our dryer would not heat and it seemed that no gas was coming from the regulator. The igniter was working fine but the burner never turned on. To check the problem, i followed the instructions to remove all body panels until I had access to the burner assembly. I dismantled both gas valve coils and tested each one for open or closed circuit using my multi-tester. I found that the three terminal gas valve coil was an open circuit and was not functioning so I ordered a new one from PartSelect and within just a couple days, had the drier back up and functioning. I also replaced the igniter due to a malfunctioning igniter that has been changed by the manufacture. I must say that PartSelect has the fastest shipping I have ever seen. One part I ordered was at my door in less than 24 hours and I only paid standard shipping...un real! OUTSTANDING....5 STAR SERVICE
Parts Used:
Igniter Kit
  • Russell from Santa Maria, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced two parts in the gas heater assembly
I removed the front panel of the dryer by removing the 2 screw that secure it at the bottom and pulling upward to disconnect the cover at the top. I then removed the two screws that hold the metal cover that secures the 2 elements in place. I disconnected the wire plugs from the 2 elements, removed the 2 elements and replaced them with the new parts making sure to place them in the same positions as before. I then replaced the housing cover and tightened the screws. Then I replaced the front cover of the dryer.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • L R from Carmel, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer worked but no heat
Initially we thought the problem was the igniter, so we ordered an igniter kit. Installed it but was unsuccessful. We then went on the websight and read further, about 50% of dryers with no heat but working had a problem with the thermal fuse.So we ordered the thermal fuse installed it, which was very easy, and success. Once the problem was diagnosed properly it was fast and easy. Recommend looking at the statistics for specific problem.
Parts Used:
Igniter Kit
  • Tracie from Culver City, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
18 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Time clock not moving .Not enough heat
Opened front panel .Tested both coils on gas valve.
Found no continuity on one of the coils. Replaced coil,
dryer works like new.
Parts Used:
M Series New Style Coil Kit
  • PHILIP from LONG ISLAND CITY, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burner would not go on on my Stack Set Dryer
Took out two front Panel screws and removed the panel. Removed Gas solenoid coil holding bracket by removing two phillips head screws. Disconnected the coil leads. and removed the coils. Connected the new coils to the leads and set in place. Replaced the holding bracket and the two screws. Replaced the front cover and the two front cover screws. Piece of Cake!
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Robert from North East, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Dryer would not get hot.
I removed the two screws holding the access panel, and removed the access panel. Then removed the lower air duct. I then checked the burner, The solenoid was not opeing the valve for the gas. I order the coils, in two day I had the coils and installed them. The dryer is working great.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Jerry from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating up
Unscrewed 4 screws,pulled off front of machine.Unscrewed 2 screws holding coils on,unplugged coils,installed new coils,plugged in coils,reinstalled 2 screws for hold down brace.Reinstalled front cover,plugged dryer into outlet(remember to unplugged dryer before working on it).started up,instant heat,works great.thanks Partselect for helping me out!!!
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Richard from New Windsor, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer was not fully drying
After replaceing several parts including the thermostats the last part I replaced the coils were the defective part. I originally metered out the themostats and they appeared to be okay but since this was my first time I thought I might have been mistaken. It turns out the last part I thought it could be was the part that was defective. I will say that it is very simple to replace any of the parts involved. The hardest part was trying to open the dryer itself. But after having to do it 3 times, I'm now a pro. I also replaced the drum belt and since I had it open I also replaced the belf idler with a newer modified idler rolller.

Putting the belt back on is easy, but it helps to view the video or a picture to understand how the belt goes around it.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Michael from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas Dryer would heat for one heating cycle but no gas afterward. Ignitor would glow.
Checked four thermocouples all showed continuity with my multimeter so they were all good. I'd read that the coils commonly went out and that these were the symptoms. Hey, it's very simple in there. Not much else could be wrong. I had a Maytag repairman come out. At first he said the problem was a blocked vent. I knew he was wrong. Then he said one of the thermocouples went out. It was $80 for him to come out. It turned out that his second diagnosis was wrong too. To repair the dryer by Maytag would have cost me $240. I gave him $80 and bought the coils for $37. They are EXTREMELY easy to replace: two screws held a bracket that held two coils. With the bracket off, I took off the old coils and slid on the new ones.
Parts Used:
M Series New Style Coil Kit
  • Jim from Foothill Ranch, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close would not get dry. Dryer started normal. Timer would not time out.
Getting to any of the parts in the Maytag dryer is easy. Tip the dryer back and slide a 4 x 4 block under the front edge. You remove the whole front panel after you remove two screws at the bottom corners of the front panel. You need to tip the dryer back to get a screwdriver on the screws. Swing the front panel up to release the top of the door panel from the top. Watch the short wires to the door switch. Unhook the door switch wires and move the front panel out of the way. The timer on the top is accessed by re-moving two screws along the top edge. There are four screws. Remove them all and tip the top of the front panel forward. You then see that two screws hold the panel and the other two screws just hold the trim.

The dryer started normal. The drum motor run when the start button was operated. The fluff cycle operated normal to indicate the timer motor was OK. On the dry cycles, the igniter heated up. The gas came on. The dryer run for some period of time and then the flame went off. The thought was that the low temp cycle thermostat sensed the dryer was hot and thus switched over to time the cycle to its end. However, the low temp cycle thermostat tested good with a meter when the sensor was removed from the dryer and heated with a light bulb. Burnt contacts in the sensor were a possible problem. I also though the radiant sensor may be bad and not recycling after it got hot. After time, the igniter would cycle on but the gas flame would not come on. I thought the radiant heater might not be tripping the secondary coil on the gas valve. The gas valve coils tested good. I was checking them cold after the dryer had cooled down. I ordered a number of parts.

I got lucky and did a test on the coils while the dryer was still hot. One of the coils in the dual booster holding coil was going open when hot. When cold it had enough continuity to let the gas valve cycle on once. After the coil got warm it went open and shut the gas valve off. When the coil did cool off, it again had continuity. I was about ready to trash the dryer when I finely found the problem. I am happy I persisted and worked the problem through to a solution. I purchased several extra sensors but saved money in the long-run. I rate this problem at the high end of complexity for the do-it your self home owner to solve. The problem was an easy fix once the real problem was found. Only 4 screws and 3 push on wire connectors (two were on the front panel for the door switch).
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Roger from Westminster, SC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer would not heat or turn off
removed front of dryer located igniter removed two screws disconnected wires then put new one in also replace thermal fuse and thermostat on back of dryer works great.
Parts Used:
Igniter Kit
  • michael from eldridge, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set, Wrench (Adjustable)
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
gas dryer would fire, but shut down before getting warm enough to dry clothes
Removed lower front cover of dryer, located coils, removed old coils by disconnecting the wires and removing the hold down bracket screws. Pulled the old coils out replaced them with the new coils by aligning the index pins on the coils with the holes in the bracket then reattached the bracket and plugged the wires into the new coils. Then closed the cover on the front of the dryer. Dryer now ignites and stays on to heat up and dry clothes.
Parts Used:
M Series New Style Coil Kit
  • Glenn from Ossian, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench set
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer not Drying
Replaced both Coils. Purchased M Series coils much less expensive buying coils together instead of seperately. Problem solved.
Parts Used:
M Series New Style Coil Kit
  • Manuel from Jurupa Valley, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!