light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
From a prior post, I learned that you simply turn the old stud one quarter turn to the left to pull it out. The new stud is then inserted and turned one quarter turn to the right and it locks in. Very easy repair.
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
I had already removed the old Ice maker, so it was no longer in.
When the new ice maker arrived, I simply pluged it in, replaced the screws that hold it in place and turned the water back on to the ice maker. It was that easy.
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Unplugged wire, loosened two screws on top took out lower screw.Lifted the ice maker up and out it came. The wiring that came with the new part was to short so we unplugged ours from the old part and used it:) was really easy and works great now no leaks
The frig/freezer shut off too often and would not stay cold.
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy fix.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
I removed 1 bottom screw and 2 upper screws useing a 1/4 inch socket nut driver. then useing a flat edge screwdriver i incerted in slot to remove wiring cluster. to install just reverse process. you maye have to cut u-shape slot for water spout to sit in.
When we moved into the house, we cleaned the fridge and broke the glass shelf and thats how it has stayed.Then I finally got over my fear of ordering things "online" and within a week, we had a new shelf which just slid into place. The shelf was packaged so well that even the UPS guy throwing over our locked gate didn't break it. Thanks Part Select....job done !!!
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!