Models > 1066690540 > Instructions

1066690540 Kenmore Refrigerator - Instructions

All Instructions for the 1066690540
106 - 120 of 131
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Parts Used:
Condenser Fan Motor Kit
  • Honz from Tucson, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Water was running into refrig from freezer and ice cream was soft
We wasted time looking for the electrical schematic on our refrigerator (the first step in the instructions). By skipping that and reading further in the instructions, the type of cooling that the refrigerator has can easily be determined by the colors of the wires that go to the defrost timer. You need to know this to set up the timer properly for your specific refrigerator. Had I just started there, the entire repair would have taken less than 10 minutes. Very simple repair and it works like a charm, no more water coming into the refrigerator and the ice cream is rock hard. Glad we didn't have to spend lots on a new appliance. Thanks Part Select.com! BH
Parts Used:
Defrost Timer
  • William from Delano, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not cooling
Exactly how the part select video described it. Threw a little curve ball figuring out which timer setting to set it to. But the instructions provided with defrost timer walked me right through it. No problem. After installing part nothing happened for about ten minutes, which had me second guessing each and every step. Then, like magic, cold air began blowing. What a relief. Thanks so much, love this site. Refrigerator works like new!
Parts Used:
Defrost Timer
  • Bryan from Midland, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Soleniod Valve Failed
The refrig. Is about 30 years old. The new solenoid looked and mounted nothing like the original. I driled holes in the frig and attach the solenoid with sheet metel screws. There were not enough fittings and hoses so I bought a braded metal hose to attach the ro line and the valve inlet. I used the parts in the kit to attach the water feed line. To the ice maker I did not try to stuff all the hoses and lines back into the cramped cavity in the frig. W ell how does it look? The solenoid sticks out a little and there are a lot of hoses behind the frig. I do not spend much time behind the frig so who cares. The ice maker is making ice!
Parts Used:
Single Outlet Water Valve Kit
  • BOB from LAKE HAVASU CITY, AZ
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Parts Used:
Condenser Fan Motor Kit
  • David from Salem, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
frosted evaperator
I was a Sears repair man for fourty eight years , so I don"t think I should say how easy this was.
Parts Used:
Defrost Timer
  • Burton from Mount ShaSTA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Parts Used:
Condenser Fan Motor Kit
  • George from Hickory, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Both the freezer and bottom of refrig too hot
Was very simple once I found out where the defrost timer was located. I had a friend walking me through trying to find the location on the phone. Not all models have them in the same place. Once the part was located all I had to do was remove the cover, unplug the old one and plug the new one in just the way the old one came off. The black wire was easy to locate on the old and just matched it up. Put the cover back on and plugged it in. It was no time till I started feeling it cool. Checked both top and bottom with thermomater and it was where it should be within 12 hours. I am happy and using it again. Was almost ready to throw it out. Did not know it was so cheap to fix one. Nothing anyone can't handle. If this woman can do it anyone can.
Parts Used:
Defrost Timer
  • Marcia from Kansas, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Parts Used:
Condenser Fan Motor Kit
  • Tom from Paducah, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Burnt out bulb
changed bulb
Parts Used:
Light Bulb - 40W
  • Thomas from Weslaco, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Parts Used:
Condenser Fan Motor Kit
  • john from thibodaux, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Freezer iced over, water leaking into refridgerator
My fridge is a little different from the video model. The Controls in the fridge are located on an "arm" which swings down when the two screws are removed from the sides. It was not necessary to remove a front plate or knobs. However, I found when I got in to it that the old timer was not held by screws, but by plstic posts which had these "speed nuts" on them. This is a little metal plate which fits over the plastic post and bends to lock it in place. When you try to remove it, it acts like a barb, holding the little sucker on. I ended up bending the ends of those little suckers up tight against the post and twisting and pulling with needle-nose pliers. I broke one post like others before me commented, but one stayed intact. The only break at the top, so there ie still post left to hold the new timer. Once it was off, I was able to replace easily. The directions for choosing the right prong were a little confusing, but follow your gut and go with the wire colors. My schematic found in the bottom of the fridge did not look like any of the drawings, but I could match the wire colors. I also asked "Just Ask" for help, to make sure. My gut instinct was right. My fridge is now working again beautifully. If a housewife with no appliance repair knowledge can do it, so can you. I fixed my dryer with PartSelect too!I will never call another repair man until I have checked this site to see if I can do it myself. Bet I have saved $600 so far at least!
Parts Used:
Defrost Timer
  • Jennifer from Cincinnati, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Refregirator would not freeze properly. It would stay in the defrost mode at times.
I did the repair just as your video showed me. It worked out great.
Parts Used:
Defrost Timer
  • Eartis from Mckenzie, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
part not like old part
The part could not be installed without home made angles which were attached to unit so that it would only protrude from back of refrigerator about 2" instead of 6".
Parts Used:
Single Outlet Water Valve Kit
  • Lawrence from Pottstown, PA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was overflowing into ice bin when filling
Thought we'd try the Water Valve before replacing the ice maker. Ordered new valve online on Saturday, it arrived on Tuesday. I installed it twice in less than 30 mins. Had a little leak the 1st time, so I uninstalled it, trimmed up the water line with a box cutter and reinstalled without issue. No leak this time. Easy Peasy. My husband said "You're good, you." :)
Parts Used:
Single Outlet Water Valve Kit
  • Denise from Manchester, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1066690540