Defrost Thermostat WR50X10025 | Official GE Part | Fast Shipping | PartSelect
Defrost Thermostat – Part Number: WR50X10025
Defrost Thermostat – Part Number: WR50X10025 Defrost Thermostat – Part Number: WR50X10025 https://partselectcom.azureedge.net/Schematics/GE/00116389i02.gif

Defrost Thermostat

PartSelect Number PS303445

Manufacturer Part Number WR50X10025

Manufactured by GE

Product Description

Defrost Thermostat Specifications

This part acts as a safety device against over-heating in case of mechanical failure.

How Buying OEM Parts Can Save You Time and Money

Troubleshooting

This part fixes the following symptoms:

Fridge too warm | Freezer not defrosting

This part works with the following products:

Refrigerator.

This part works with the following brands:

General Electric, Hotpoint.

Part # WR50X10025 replaces these:

914074, AP3190397.
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
1 question answered by our experts.
Sort by:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer Repair Stories
Average Repair Rating: 3.4 / 5.0, 9 reviews What's this?
Sort by:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Tim from West Palm Beach, FL
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Parts Used:
WR50X10025
Freezer coils icing up, fridge too warm
Had to remove inside panels to expose coils in freezer. Used hair dryer and towels to de-ice. Reading online learned about defrost heater (long thin glass tube with wire coil in it I could not see b/c up under the inside of the coils). Who would have guessed freezers have heaters in them!! And learned the defrost timer (inside the fridge) is just a continuous clock turning on and off the defrost heater. Anyways I used a screwdriver to turn the timer to defrost mode and by disconnecting the wires from each end of the heater and measuring the voltage, I found 70 volts there. Hmmm. I didn't know what was the right volt amount.
Reading online I also found out the defrost Thermostat is basically a temp actuated on/off switch for that heater, so that while the timer is sending *120* volts to the heater (which gets red hot by the way) the therm switches the heater off when the temp gets high in the freezer.
I eyeballed the therm ( it looks like a little can) and I saw that it was coming apart. The key at this moment is you can cut out and bypass the therm to see if the heater works. If it does you know the therm is the bad boy. But only do this as a momentary test or the heater will probably set your fridge on fire after a while!

Always remember to unplug the fridge when you are messing with the wires! And dry it up inside before putting your hands and tools in there!

So I ordered a therm using the model # of the fridge. Had to cut the old out and strip / wire nut the new one in.

Took too long b/c I was hung up on the heater being bad (after all it didn't heat up when I put the timer in defrost) and not knowing about the rights volts to the heater.

PartSelect helped out great! Thanks!
29 of 32 people found this instruction helpful.
Was this instruction helpful to you?
erik from cut bank, MT
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Parts Used:
WR9X502, WR50X10025
the freezer worked but the refrigerator did not cool. The freezer iced up and did not defrost.
Replaced the defrost timer . It plugged in under the cover for the lights and controls in the refrigerator area. Replaced the deforst thermosat, took the rear cover off (at the back of the freezer) , cut the two wires and relaced the thermosat using wire nuts. Total repair time 30 minutes.
17 of 23 people found this instruction helpful.
Was this instruction helpful to you?
David from Shalimar, FL
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers, Socket set, Wrench set
Parts Used:
WR50X10025
Refrigerator section not cold, freezer section cold
Based on the relatively young age of refrigerator, I suspected the defroster electrical circuit. The evaporator core in the freezer was frozen solid, which confirms that the defrost heater circuit is not working. Thawed out (with a hot air gun) and disassembled the freezer section to access the evaporator core and defrost heater. If you have an ice maker, you will have to remove it to disassemble the freezer section. Confirmed with a voltmeter and ammeter that the defrost heater was not getting voltage. When the defrost heater is working, it will glow with an orange color. Also confirmed with a voltmeter that the defrost timer, located in the refrigerator section was working correctly. You can use a common blade screwdriver to rotate the timer through the cold and defrost cycles. Finally, I determined with a voltmeter and ammeter that the defrost thermostat, located on the evaporator core was not switching the defrost heater voltage. Ordered a new thermostat ($12) from this website and installed it. Refrigerator is as good as new. Be careful, there are many electrical hazards during the troubleshooting phase. Safety first.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Richard from LONG BEACH, CA
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Parts Used:
WR55X24064, WR51X10038, WR50X10025
COLD FREEZER WARM FRIG
After several defrost sessions I realized we had a component problem. Freezer and frig would cool up and maintain for a week or so but then the frog would go warm and the freezer would be ice cold. SO it was then I knew it was a defrost sequence matter. Thanks to Parts Select and their part to culprit algorithm it provided me the several most likely parts to be at fault. Since not having a voltage tester it was R/R time so I started with defrost timer and then went on from there. So all in told the bill for parts was around $120 still cheaper than a repair service call and obviously buying a new unit. Replacing the parts was simple, the most difficult being the defrost heater element but nothing to throw your hands up. My advice is just stay patient, do plenty of research and tackle it, you will save hundreds of dollars. Living without a frig for several days can be uncomfortable but I was absolutely determined to salvage the frig and save money and it was all worth it.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
hung from herndon, VA
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
WR51X10038, WR50X10025
no problem
The part i received fit perfect, i just removed the old part and put the new part in with the screw driver.Really easy
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
samuel from windsor mill, MD
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Parts Used:
WR50X10025
refrigerator compartment too warm
Unplugged fridge and removed back panel inside freezer compartment . Unclipped defrost thermostat and snipped off with wire cutters . Installed new defrost thermostat with wire nuts , clipped back on , re-installed back panel , turned on fridge and within a couple hours food compartment began cooling down . Thermostat looks like a small metal can clipped onto the heating coils with 2 wires attached . Also noticed excess ice build up on coils melted and drained into pan under fridge once unit started working .
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
david from torrington, CT
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Parts Used:
WR50X10025
freezer worked but thelower part where the milk and the fruit are was warm checked on your site to get help and you were on the money with telling me it was the thermostat i orderd it and it solved the problem thank you.
i took the backing off with a screwdriver, cut the wires and put the 2 wires on that came with the thermostat. p.s. make sure you pull the power plug before you start.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Michael from BRADENTON, FL
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Parts Used:
WR50X10025
Evaporator coil freeze up
Up plug from wall removed rear access cover in freezer let thaw out and replace two wire sensor had previously checked out knowing the defrost strip was good and the defrost thermostat was visually deformed and tested open at freezing and 40 degrees
1 person found this instruction helpful.
Was this instruction helpful to you?
tom from WESLEY CHAPEL, FL
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Parts Used:
WR50X10025
freezer iceing up
removed screws holding back plate removed air devise pul slightly out lift straight up and ou remov 2 screws in the fan cage remove ice maker 2 screws and a plug in connector.pull back fram slowly forward angle to the left remove.you'll see condenser in front of you.thermostat is to the right attached to top coil of condenser clips on remove.two wires cut close to old thermos and remove install new one make sure back which is plastic faces you.attach wires with wire nut or inline #14 slices.just go in reverse to finish. maakesure you unplug fridge first and of course plug her back in.wait 24 hours for everything to settle down.
1 person found this instruction helpful.
Was this instruction helpful to you?
Customer Reviews
Average Rating:
4 Reviews
5
out of 5
Filter By Rating:
  • 5 Stars
    4
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Stars
    0
Sort by:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Model Cross Reference

This part works with the following models:

PartSelect Number: PS303445
Manufacturer Part Number: WR50X10025
Brand
Model Number
Description
General Electric
38181KBPARWW
Refrigerator
General Electric
38181KBPCRWW
General Electric
38181KBRARWW
General Electric
38185KBPARBB
Refrigerator
General Electric
38185KBPCRBB
General Electric
38185KBRARBB
General Electric
38187KBPARCC
Refrigerator
General Electric
38187KBPCRCC
General Electric
38187KBRARCC
General Electric
38371PBRBRWW
General Electric
38471PBRBRWW
General Electric
38471PBRDRWW
Refrigerator
General Electric
38471PBRERWW
General Electric
38471PBRFRWW
General Electric
38471PBRJRWW
General Electric
38471PBRLRWW
General Electric
38471PBRMRWW
General Electric
38471PBRNRWW
General Electric
38471PBRRRWW
General Electric
38471PBRURWW
Refrigerator
General Electric
38471PBRVRWW
General Electric
38471PBRWRWW
General Electric
38481KBRARWW
Refrigerator
General Electric
38481KBRCRWW
Refrigerator
General Electric
38481KBRDRWW
General Electric
38481KBRKRWW
General Electric
38481KBRORWW
General Electric
38481KBRTRWW
General Electric
38481KBRVRWW
General Electric
38485KBRARBB
Refrigerator