October 31, 2019
Hello, The freezer section not getting cold the setting is at -2 degree .The coldest it get is 52 degree the condenser coil is clean fan motor running, no ice on evaporator coil ,the fans in the freezer are running.I place the temperature sensor in a cup of ice @ 32 degree the resistance 12.5 k ohm. What should the reading be? The refrigerator section is ok 38 degree.What else can i check?Thanks,
For model number GFSS6KKYASS
Hello Cleveland, Thank you for the question. With the sensor warmed up to room temperature the sensor should read approximately 6.2K Ohms at 68°F. With the thermistor submerged is a glass full of ice water, the sensor should be very close to 32°F which should read approximately 16.3K Ohms. Hope this helps!