Models > TFG27PFSBAA > Instructions

TFG27PFSBAA General Electric Refrigerator - Instructions

All Instructions for the TFG27PFSBAA
1 - 15 of 316
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Internal water lines brittle, cracked, leaking
First of all, the larger white plastic tubes in this thing are 5/16" OD, which no plumbing store seems to stock. At the lower left rear end there are 2 tubes, one for water and one for ice, that are doomed to fail being in proximity of a heat source - they essentially get cooked to the point of becoming brittle and cracking. The smaller tube and union can be easily found, but do yourself a favor if the larger one cracks and order the plastic tube and water tube union here, and just cut off the brittle part and amend the old tube using the union.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Marty from West Bloomfield, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
118 of 136 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Sticking Light Switch
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
Parts Used:
Light Switch
  • Jonathan from Lilburn, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
117 of 145 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The oiginal Ice Bucket auger became rusty and discoloered the ice.
I went on line to find the part. Luckily I found PartSelect.com. All I had to do was enter the model number into the search box and scroll through the list of parts.
I ordered the part over the weekend and recieved it on Tuesday!
All I had to do was remove 4 screws from the original Ice Bucket and attach the new one.
Perfect fit in under 15 minutes!
Awesome place to do business with! I hope I never have to do another repair, but if I do I will go to PartSelect first!
Parts Used:
Auger and Ice Bucket Assembly
  • Michael from Antioch, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
66 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser leaked - tubing broke
Ordered parts from another vendor - got wrong parts (1/4 in parts instead of 5/16 in parts). With your parts, I just cut out the bad portion of the tubing, and replaced it using the 2 union connectors. Thanks.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Thomas from Poway, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
48 of 65 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator side of the side by side refrigerator stopped regulating its temperature causing cans and bottles to burst.
I removed the back panel held in place by 5 screws. I located the thermostat and disconnected it from the wire connection to another part. Due to the connection requirement, I had to cut the wires from the original part and splice the connector with wires to the new part. After securing the spliced wires and covering in electrical tape, I replaced the panel and all screws.
Parts Used:
Defrost Thermostat
  • Jonathan from Cary, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
36 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This seems to be a design problem because I have to replace this part about every other year since we bought it. I tried to talk to GE but all they want to do is send a service man out to replace the part for about 100.00, But I do it for around 15.00. I just think they should find out why the rubbe
The repair is easy, just pop the grill off around the ice and water door, then there are 4 screwws to take out so the touch pad can be moved out of the way to unsnap the old door assm. and snap in the new one and wait about a year and a hald to order another one!!!!!
Parts Used:
Dispenser Door Assembly or Flapper
  • Jeff from Columbia City, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
26 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wouldn't dispense ice
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
Parts Used:
Dispenser Switch
  • george from palmetto, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dirty ice from rusty auger
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.
Parts Used:
Auger and Ice Bucket Assembly
  • William from Chesapeake, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
19 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Parts Used:
Plastic Tubing - 5/16 Inch Union Connector - 5/16 Inch to 5/16 Inch
  • Gregory from Yucca Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
20 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
Dispenser Door Assembly or Flapper
  • D from ZELLWOOD, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water line leaking behind refigerator
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Michael from Merrimac, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Parts Used:
Actuator Pad
  • Lowell H from Gilbert, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFG27PFSBAA
1 - 15 of 316