Magnetron shorted out blowed 15 amp fuse
removed cover of microwave, replaced fuse checked for short at plug with volt ohm meter, there was a short at the plug then checked magnetron for short and there was a short at the magnetron, the cap and diode checked good.

replaced magnetron IT IS WORKING GREAT !!
Parts Used:
Magnetron
  • Duane from Jacksonville, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Capacitor went out
Unplugged and replugged everything and it worked very easy job thank you
Parts Used:
CAPACITOR,ELECTRIC APPLI
  • Al from CROSS PLAINS, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken fan assembly
everything went great and was just as planned. We now have cool air in the shop for us to do our handy work. Thanks, Dale Heltzel
Parts Used:
FAN ASSEMBLY,AXIAL CLAMP,SPRING
  • Drucilla from Vinita, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
0 of 6 people found this instruction helpful.