ice maker did not make ice
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.
Parts Used:
Cycling thermostat
  • DAVID from TINLEY PARK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
47 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator/Freezer Not Cooling
First of all, let me say that I'm a 50 year old single woman. If I can do this repair, anyone can! After unscrewing the back of the unit that houses the compressor, I found the relay overload switch which is attached to the compressor. I pulled the part off and discovered that it comes in one piece. The replacement part came in 3 pieces. I intially thought they sent the wrong part. After a little thinking outside of the box, I figured out that the replacement part was indeed the correct part and that it comes in 3 pieces instead of one. It would have taken 5 minutes to repair if I had realized this early on. Once replaced, the refrigerator/freezer was cooling within 10 min. I sent the Run Capacitor back after telephoning a customer service rep. She was so courteous and helpful! What a fabulous company. I highly recommend. I saved myself approx. $250.00 doing it myself.
Parts Used:
Run Capacitor Relay Overload Kit
  • Melinda from Modesto, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
44 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not exit defrost mode (continual defrost)
Unplug the refrigerator. Remove face plate located in the upper back of the refrigerator compartment. Remove face place bracket on the right using nut driver. Removing these screws also frees the metal case enclosing the Defrost Timer. Pull the case away from the back of the refrigerator exposing the Defrost timer. Remove the electrical plug from the Defrost Timer. Then remove the Defrost Timer from the case by removing the two screws securing it. Reverse the procedure to install the new Defrost Timer.
Parts Used:
Defrost Timer - 120V 60Hz
  • Leon from Chaparral, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
44 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster element and or thermostat was not working.
removed the shelves in the freezer compartment and removed the two screws holding the back panel on over the coils and simply removed the male wire plug from the female plug and pulled the wires for the heating element down thru the coils and released the spring clip holding the element in place and removed, and installed the new element and thermostat in reverse order. Very simple.
Parts Used:
Defrost Heater and Thermostat Assembly
  • Thomas from Cottage Grove, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
39 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Yoke auger tore hole in plastic ice enclosure
Very simple repair. First Remove ice tray. Next remove enclosure. Believe there were 3 screws to remove enclosure (1 bottom, 2 top). Slide enclosure out slowly to gain access to power connector mounted on back wall. removed components from enclosure (motor and solenoid). Take extra care removing solenoid with spring/rod as it is 3 separate pieces (spring, rod, and coil). Easy to figure out reassemble but easier if you take note during disassembly. Took me a while to get yoke off from motor assmbly. noticed they were reverse threads (lefty). So to remove yoke from shaft had to turn CW vs CCW on regular threads. Once had yoke off, rest of assembly was easy. Mounted motor, reinstalled yoke. Put entire re-assembled enclosure back in fridge. Slide in part way, to give yourself plenty of room to plug power connector in. Reattach assembly with 3 screws. Works like a champ.
Parts Used:
Ice Enclosure
  • Craig from East Fairfield, VT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
36 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fountain flap was broken and let warm air in.
We just followed the instruction sheet that was included in the parts package. (instruction sheet has pictures) I just removed the 2 screws from the front and then disconnedted the element. unscrewed a couple more screws put on the new parts and reconnected the element put back the screws and it was done! I'm a single womand so me and my 23 yr old daughter did this project together. I ordered the parts early in the day and got them the next day. I only paid for 2-3 day shipping. I have ordered parts from Sears. They never have them in stock! The last order cost me $19.95 to ship. I waited more than 2 week for them to arrive. With Partselect the job was finished in 3 days!!
Parts Used:
Water Filter Ice Dispenser Solenoid and Door Kit Upper Hinge Cover
  • Rita from Kansas City, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
40 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Parts Used:
Condenser Fan Motor Kit
  • robert from nashotah, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor "grounded" and quit running
Replaced the compressor with the new one I purchased from you. Installed new parts and recharged unit. The refrigerator / freezer is working better than new. Thanks for the great deal on the compressor. It was here in 3 days. All the parts fit exactly and had no difficulty in the installation or startup. The directions for the wiring were a great help also. Thanks again.
Parts Used:
Compressor Kit
  • Mike from Baytown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
59 of 118 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator not cooling
Through experience I determined the problem was with the compressor trip switch. It's the small white piece that looks like a flat fuse.

The parts arrived in 3 working days. Instructions were included - very easy to understand. From start to finish I replaced the switch in about 15 minutes. Frig is now working perfectly.

3 pieces come along in the kit - however, all I needed was the switch, but for the price I changed out all three to assure compatibilty.

I also ordered the cover which was not needed.

A Happy Customer! {:-)
Parts Used:
Relay Overload Kit CLIP
  • Ronald from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench (Adjustable)
35 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
Parts Used:
Water Tube Connector/Union - 5/16 to 5/16
  • Leo from Salem, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
43 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Water Fill Cup and Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
doesn't get cold at all and freezer was warm condenser wouldn't run
removed all 6 screws in back of fridge. located the condenser the relay was a white like circut to the left of the unit. The entire pience comes off easy using a flat screw driver to pry it off the pins.
The replacement came in 2 pieces insted of 1.
I replaced the relay and then the overload reconnected the wire harness back the way it was before. The new relay has a larger connector prong for the live wire so the kit comes with a jumper wire so the original wire harness can be used without splitting the cabel made the repair very easy. Also the new capacitor is bigger and better so I replaced that as well. The capacitor makes sure the relay gets stable current so its good to have a working one.
Parts Used:
Run Capacitor Relay and Overload Kit
  • Jean from Fremont, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
27 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Parts Used:
Condenser Fan Motor Kit
  • Florentino from Windsor Locks, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Parts Used:
Condenser Fan Motor Kit
  • Janet from Hillsboro, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice and Water Dispenser Would Run on After the Glass Was Removed
I am going to be completely honest here. This problem had persisted for months. I finally decided that I would buy all the associated parts and repair the unit hoping to cover the problem. Much to my surprise, after carrying out the repair, using the instructions provided by PartSelect, I still had the problem. I decided to remove and LUBRICATE the button which depresses the Limit Switch when you push a glass against the rubber membrane. Low and behold the problem was solved. The frig is nine years old, so I feel I may have prevented other problems in the future by replacing the three parts. It was a follow the directions sort of repair. I was very pleased with PartSelect response to my order (received it next day) with standard shipping.
Parts Used:
Limit Switch - 2 Terminal Dispenser Control Board Ice Dispenser Solenoid and Door Kit
  • Doug from Berkeley Springs, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!