Models > GD22DKXHW03 > Instructions

GD22DKXHW03 Whirlpool Refrigerator - Instructions

All Instructions for the GD22DKXHW03
1 - 15 of 659
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
replacing parts only
the prices you had were great, now I see there was an increase in the parts.
thank you
Parts Used:
Refrigerator Door Shelf Bin Refrigerator Crisper Drawer with Humidity Control
  • JULIA from BRONX, NEW YORK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
690 of 768 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
track of the pan become broken
Buy a new crisper pan,slide out old one ,slide in new one
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Darrell from Cedar Bluff, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
422 of 444 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Norbert from Sugar Land, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
393 of 414 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
inconsistent compressor and condensor fan operation
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
Parts Used:
Thermostat Assembly
  • Steve earney from Brooks, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
305 of 320 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drawer guides broken
Simply pulled out old drawer and replaced with new one. This broken drawer really bothered my wife so this simple repair earned me alot of points at home. Lord knows i can use all the extra points i can get. Thanks for the quick shipment of the part. 2 days from time of call to part on my door step. Thanks again
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Paula from Chesterfield, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
316 of 409 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Parts Used:
Bi-Metal Defrost Thermostat
  • Cathy from Winter Park, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
154 of 179 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Door quit closing on it's own......
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • T.w. from Batesville, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
140 of 153 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)
Parts Used:
Thermostat Assembly
  • michael from clarksville, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
116 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator fan stopped working
1) removed the face plate that runs 3/4 way up the back of the freezer side. a total of 8 screws. (6")
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Antoni from vail, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
95 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
119 of 194 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling properly.
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "
Parts Used:
Thermostat Assembly
  • Eddie from Gretna, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
73 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Criper drawer
First I opened the fridge and removed the broken drawer. I then removed the new drawer from its shipping container and placed it on the tracks in the fridge. I then closed the fridge. Perfect!
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Victor from Morgan Hill, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
105 of 174 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drawer Broke
I first opened a beer to gain some liquid courage. The crowd (dog and 2yr old) were anxiously watching while I first grabbed hold of the refrigerator door. The door swung open with a mighty roar exposing the huge gaping whole where the previous crisper pan once shelved itself in glory. I took aim, and slid that new crisper pan in like it was meant to be. The crowd went nuts...but probably because the tv commercial was over and Sesame Street was back on. Thanks partselect!
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Brian from Fort Collins, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
66 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wanted to install ice maker in my freezer
I was clening my uprght freezer and noticed that it was preped for an icemaker. I first went to the Whilpool website and could not find my part as my freezer was a 2008 model.

I saw PartSelect on the search page and went to thier site.
I put in my modle number of the Whilpool Ice maker kit that was on the back of my freezer. PartSelect had the part in stock and approx $18.00 less than the other kits listed on the Whilpool site (that did not match my kit number). I orderd the kit on Sunday and it arrived on Wednesday. It took less than and hour to install. Every part I needed was included. The following day I installed the water line and now I have an extra icemaker.
Parts Used:
ICEMAKER
  • Donald A. from ORLANDO, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
74 of 105 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Would Not Go On In The Refrigerator
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Parts Used:
Light Socket Kit
  • DANIEL from MINNEAPOLIS, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
61 of 77 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GD22DKXHW03