replacement freezer keys
I accidently threw away both freezer keys to our upright Gibson and G.E. Freezers!!!! I had no luck finding replacements locally, so I got on the internet and came across PartSelect.com. I called them on the telephone; and after giving the model numbers of my freezers, the keys were on their way!! I received the keys very quickly and both worked perfectly. I would highly recommend Partselect.com. Charlotte M. Bishop
Parts Used:
Freezer Door Key
  • CHARLOTTE from SEDALIA, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
70 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice and frost were forming in a frost free freezer
The old gasket was obviously gapping, partially from age and partially from damage during a move. To make the repair, I loosened the screws that are under the gasket and hold it in, but did not remove them. Once all were loose, I removed the old gasket, then starting at the top, ran a thin bead of food grade RTV under the portion of the door that captures the gasket. I put the sealant on that edge only, then carefully worked one of the short edges of the gasket under the plastic and tightened all but the corner screws. I then ran the RTV down the inside of the hinge side of the door and repeated the process, this time tightening the top screw and the hinge side screw at the top, but leaving the bottom most screw loose. I repeated the process on the opening side of the door. The bottom was the hardest because the gasket seemed just a little long and it was hard to get the RTV up and behind the door portion, but after a couple tried I got a good bead of sealant then slid the gasket under the door capture and tightened all the remaining screws. After closing the door, it was obvious that there were places were it did not seal well. I used some cardboard strips, cut from the box the gasket came in, to place inside the freezer, between the hard plastic of the door and the inside of the gasket where it laps over the screws. This helped a lot, but there were still a couple small areas, so I used more cardboard, from the outside, between the main portion of the gasket and the rim of the gasket. This eliminated all the gaps. I let this sit overnight and this morning removed all the cardboard for a great sealing freezer.
Parts Used:
Refrigerator Door Gasket
  • Louise from Ocala, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
75 of 97 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer door wouldn't stay shut due to two irresponsible children.
We ordered the part, which was a key, tied it on the freezer door handle, locked the door and voila, the problem was fixed. (We still have the children. :-)
Parts Used:
Freezer Door Key
  • Paul from Cape Coral, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
24 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer thawing at about 20 degrees
Turned freezer off at themostat and unplugged freezer. Removed 2 screws at front 2 at the back and 2 at the top. Lowered top cover and removed evaporator fan bracket (2 more screws) removed themostat capulary tube( 1 screw and bracket) then unplug fan motor. Removed motor from bracket (2 screws). Put on new fan motor then removed fan blade from old motor and put on the new motor. Remounted fan motor bracket and thermostat capulary tube. Remounted top cover, plugged freezer in the set the thermostat to 4 and freezer is working fine and doing its job. I orderedmotor on a Sunday and it was shipped on Monday and I received said part at 7:pm on Wednesday.
Parts Used:
FAN MOTOR EVAP 115V
  • Nathan M. from Bunnell, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace a damaged door gasket
Removed old gasket by loosening all the screws. Inserted new gasket. Be careful to prop up the plastic shell so that ALL screw holes line up, especially at the bottom, and that shell is not tilted. Then carefully insert gasket inch by inch and fasten very other screw, best from bottom up. Make sure that the gasket lip is clearly under the shell and engaged with it. Before you do anything you have to straighten out ALL the kinks with a heat gun. Do not get too close. It takes a while.
Parts Used:
Refrigerator Door Gasket
  • Jorg from LOS ALAMOS, NM
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
14 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost function in freezer was not working, while the refrigerating side was warm
1. Turned off and unplugged the refrigerator.
2. Removed the lower back panel inside the freezer with a screwdriver.
3. Unplugged the thermostat. (No tool is needed)
4. Ordered a new thermostat from PartSelect and it arrived in 2 business days.
5. Plugged in the new thermostat..
6. Put the lower back panel inside the freezer with screwdriver.
7. Plugged in the Refrigerator and turned the power back on.
8. It is working again!!!
Parts Used:
Defrost Thermostat
  • Sophia from San Antonio, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Parts Used:
Defrost Thermostat
  • Robert H. from Grand Blanc, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lost Locked Freezer Door Key
Had to drag the full freezer out from the wall to expose the name plate, got the Model # and S/N and found the key on the partselect website in minutes. It was cheap so I got two. Other than FEDEX not knowing my address correctly, when I finally got the key it worked fine. Not a problem anymore.
Thanks
Parts Used:
Freezer Door Key
  • Robert from San Rafael, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    Less than 15 mins
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Parts Used:
FAN MOTOR EVAP 115V
  • Mike from Los Banos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would not turn on.
The part was as simple as unpluging a appliance and plugging it back in.
Parts Used:
Freezer Electronic Control Board 115 V - White
  • Peggy from SUMMERVILLE, SC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Door Leaking
My issue was water leaking from the door. I thought it was the gasket, so I removed the gasket and the entire panel off of the door. There was water behind it that had soaked the cardboard seal, so I left that front part off for over a week to let it dry. We determined between us and our two toddlers that perhaps the door hadn't been properly closed enough on a number of occasions, so before I bought a $100 gasket, I'd try making sure the door was shut with tape, turning the freezer on and seeing what happened. There was no water after a few days, so on another user's suggestion I purchased the $15 key and twist tied it to the freezer door. Now I am locking the door after use so we won't have leaking water any longer.
Parts Used:
Freezer Door Key
  • Danielle from LAKEWOOD, CO
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Parts Used:
Defrost Thermostat
  • Elvin from Gardner, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cannot be made
The called for part is the wrong size due a false correlation between the called for part number and the PartSelect number. I order twice and each time it was a 31 by 65 in. gasket not the appropriate 31 by 60 in.. Both were returned but no resolution.
Parts Used:
Refrigerator Door Gasket
  • Thomas from BATON ROUGE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer stopped freezing
popped out old controller, popped in new one, took all of about 30 seconds
Parts Used:
Freezer Electronic Control Board 115 V - White
  • JEROME from RICHMOND HTS, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Parts Used:
FAN MOTOR EVAP 115V
  • Walter from SALT LAKE CTY, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.