This was the second part I tried. The defrost timer was first, but that did not fix it. To do this I had to remove the ice maker and the back plate of the freezer. Then I defrosted the coil and cut the wires. stripped them back and installed the new thermostat. re-assembled and tested. has been working great ever since.
Refrigerator would not run but interior light was on.
I unplugged the refrigerator, then opened the door and removed four screws holding the plastic electrical panel to the interior top of the main refrigerator compartment and noticed the cold control was corroded badly, apparently from moisture in the panel. I ordered a new one from partselect.com. When it arrived the next day, I then pulled off the control knob, unclipped the cold control, unplugged the three wires to the control, then removed the styrofoam insulation blocks holding the thermocouple wire and then removed the thermocouple wire to complete the removal. I then reversed the process to install the new thermostat and control. That is repositioned the thermocouple wire, put the insulation blocks back to hold the wire, then replugged the three electrical wires, clipped the control back and pushed the control knob back on and finally screwed the panel back to the top of the main compartment and plugged the refrigerator electrical cord back in to provide current to the refrigerator. It immediately started up and ran fine. Total time - about 8 minutes.
The Crisper Drawer Glass Shelf slid out of the frame while being cleaned and shattered.
The repair didn't require any tools at all. Just simply slide the new glass shelf carefully into the the frame and while holding it horizontally slide the frame back into the rails. This took less than a minute to accomplish. Very satisfied with the results.
Don't ever tell your 11 year old to clean the refridgerator. Something will almost definetly get broken like the glass shelf, but luckily I had parts select which in no time assisted me to find the exact part. I ordered the part, it came quickly and I replaced within seconds. Thanks.
Frig area was at about 50 degrees and would not get cooler. Freezer was working great. Empty the freezer and remove the two screws that hold the back panel of the inside of the freezer on. Pull the panel out and you will see the fan that is mounted to the back of the panel. If the fan is not running, disconnect it (quick connector) and check to see if there is voltage coming to it from the connector (should be 120VAC between the two wires). If there is power, and the fan was not working, replace the fan.
Fan just snaps into the holder on the back panel and plugs into the quick connector. Make sure you clear any ice build-up in the hole between the freezer and the frig that the fans blows through. Put it back together and verify the fan runs.
- Unsnapped old light socket from top of Frig - Disconnected elect wires - Reconnected elect wires to new light socket - Snapped new socket in place - Done in less than 2 min.
No long shelf came with our new refrigerator, Frigdaire did not have one so I went on-line from you and it fit perfectly, now everything does not have to be in one big heap.
Freezer seemed ok, though frosty, but the bottom section was not cold enough, and the compressor seemed to run constantly.
The lower compartment was hovering around 50 degrees. Logic told me that cold air was not being driven from the freezer to the lower compartment. At first, I found the passageway between freezer and lower compartment was blocked with frost/ice, which could have been the entire problem. But why was that ice accumulated there? After defrosting, the problem was only partly solved. A few how-to videos suggested that the defrost timer was a common problem, so I tried that, the part was about $11, with minimal improvement. So I concluded that the fan was not driving cold air from the freezer to the lower section. I tested the fan by removing the freezer back panel completely, wiring the fan to an old ordinary power cord, and plugging that in to a wall outlet. The fan would not start on its own, would only turn if I gave it a spin, and then was very weak - I could stop it with a finger without pain! When my new fan arrived, I again removed the back panel in the freezer and replaced the fan, just a few screws to remove, then swap the fan blade to the new fan motor. The process was simple and obvious. Now the lower section stays near 40 degrees, though I'm not convinced that's the only problem-there seems to be a lot of variation in the temperature. BTW, I had also confirmed the defrost heating element was functional by activating the defrost timer (see youtube), to eliminate that from the diagnosis.
Door shelf retainer bar snapped easily into place.
The fit was good even though the top retainer bar seems to be a tighter more secure fit than the middle retainer bar.The retainer bars are made to simply snap into place. Great to receive these replacement shelf retainer bars. Thanks!!