Microwave tripped circuit breaker when turned on
Remove vent cover then remove touch screen control panel. When you remove control panel take photo of where everything is plugged in then unplug and remove control panel. 3 door switches located next to door in a plastic chassis. Test each switch with current tester. Remove the bad switch and replace with the new one. You tube DIY helped.
Parts Used:
SWITCH
  • Arthur from LUTZ, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
26 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed glass Cooking Tray
I Put The New Tray In the Microwave
Parts Used:
Glass Cooking Tray
  • John from HICKSVILLE, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
13 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Pressing the start, microwave will start and dies out. Electric is tripping.
The diagnosis is about an hour. Coz, I need to open the control panel, got a tester, and trsted all critical parts inside the panel.
Also, replaced the fuse just to make sure its a new one. Found out it was a switch (bottom part) that control the open/close of the microwave door.

When found out the problem, the rest of the work is easy.
Parts Used:
SWITCH
  • ARNEL from WAUKEGAN, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!