Door wasn't closing correctly.
My husband removed the old hinge, by taking out the old screws and the old hinge and attached the new one, by inserting the new hinge and the new screws. It was as easy as 123.
Took out the screws(8mm). Used pliers to close new hinges. Re-installed the screws with as large washers as would fit(to hopefully prevent the hinges from cracking at the screw holes like the originals did). I like this supplier, part was easy to find, correct part, shipped fast, price was good.
First I removed the clamp, pulled out the part, and diconnected the two wires on the side and a small screw. Reconnected the new part with the small screw, connected the wires and plugged the part back to the side of the motor. Whaa La, Done.
While defrosting freezer tossed the drain plug with ice and water into the sewer system.
Opened mailer and bag and place the drain plug into the drain. fit perfectly. In fact it is better than the one lost since the original needed a screwdriver or tool to remove the plug. This one has a flang or finger turner on it so that it can be removed. Also, does not interfere with items in bottom of freezer.
open lid put baskets in. it should also be noted that we originally ordered two baskets and do to some ones over sight we only recieved one. We called and to our surprise the other basket was sent out that day. If the occasion arises we would order from you again.
remove 2 screws from thermostat cover on side of freezer pulled temp nob off then removed temp control and copper temp sense rod by pulling out then unhook wires then reverse procedure to put back together
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
I replaced the thermostat. (Note: On a chest freezer, there is a copper tube going up into the wall of the freezer. The capillary of the thermostat goes into this tube.) 1. Unplug freezer. 2. Remove temperature knob. 3. Remove screws and remove cover plate. 4. Unclip old thermostat. 5. Using pliers, gently pull down the rubber seal on the capillary where it enters the copper tube. 6. Pull capillary out of copper tube. (In my case, the capillary was not free to pull out. I had to grasp the capillary with pliers and tug hard.) 7. Place rubber seal over the new capillary. 8. Insert the new capillary into the copper tube and put the rubber seal over the end of the copper tube. 9. Install thermostat body in the cover plate using the clip on the thermostat body. 10. Replace cover plate and temperature knob.