Models > DH5010E

DH5010E ((AWYCKRT)) LG Air Conditioner - Overview

Sections of the DH5010E

[Viewing 1 of 1]
Keep searches simple, eg. "belt" or "pump".
Switch Assembly – Part Number: 6600A30003C
Switch Assembly
PartSelect #: PS3529251
Manufacturer #: 6600A30003C
  No Longer Available
ROLLER – Part Number: MHA62753001
ROLLER
★★★★★
★★★★★
(1)
PartSelect #: PS11712156
Manufacturer #: MHA62753001
$17.97
  Special Order
Turbo Fan – Part Number: 5900A20007B
Turbo Fan
PartSelect #: PS3528580
Manufacturer #: 5900A20007B
This turbo fan is commonly used in the assembly of air conditioners and dehumidifiers. The fan is used to draw air through the unit and move it forward into your home. If your fan is cracked, broken, ...
$10.70
  Special Order
DISCONTINUED – Part Number: 6601A30006A
DISCONTINUED
PartSelect #: PS3529307
Manufacturer #: 6601A30006A
  No Longer Available
Damper,Compressor – Part Number: 4830A30005A
Damper,Compressor
PartSelect #: PS3523943
Manufacturer #: 4830A30005A
  No Longer Available
Overload Protect – Part Number: 6750U-L039A
Overload Protect
PartSelect #: PS3529566
Manufacturer #: 6750U-L039A
$16.86
  In Stock
MOTOR ASSEMBLY,AC – Part Number: 4681A20040H
MOTOR ASSEMBLY,AC
PartSelect #: PS3579214
Manufacturer #: 4681A20040H
  No Longer Available
SHROUD ASSEMBLY – Part Number: 4999A10002B
SHROUD ASSEMBLY
PartSelect #: PS3587953
Manufacturer #: 4999A10002B
  No Longer Available
Condenser Assembly,First – Part Number: 5403A10008A
Condenser Assembly,First
PartSelect #: PS3527809
Manufacturer #: 5403A10008A
  No Longer Available
Power Cord – Part Number: 6411A20001V
Power Cord
PartSelect #: PS3529047
Manufacturer #: 6411A20001V
  No Longer Available
Switch,Rotary – Part Number: 6600A20001A
Switch,Rotary
PartSelect #: PS3529249
Manufacturer #: 6600A20001A
  No Longer Available
PCB Assembly,Main – Part Number: 6871A10055A
PCB Assembly,Main
PartSelect #: PS3529660
Manufacturer #: 6871A10055A
  No Longer Available

Questions And Answers for DH5010E

Be the first to ask our experts a question about this model!

Common Symptoms of the DH5010E

[Viewing 1 of 1]
Unit says bucket is full when it isn’t
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Parts Used:
Turbo Fan
  • Cheryl from Bradner, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller wheels
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
Parts Used:
ROLLER
  • MICHAEL from LEBANON, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!