Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frostfree Amana failing to defrost
First step, call the repair man. He listened, and then said to get a new refrigerator, since this one is 28 years old and the repairs could amount to a significant part of the price to buy new. Even if he fixed this, it could develop other problems, yada. So we went out to buy and discovered nothing suitable that would fit in that slot of our kitchen! We'd need new counter top and cabinets to fix this problem! So we went to the Internet and searched to find the likely source of the problem and the parts schematic at PartsSelect.com. Yah! We ordered the part, and then found we had no idea how to install it. Sooo, back to the Internet, and eventually got some good clues - it goes in the kick space under the front, and just plugs in, once you can get to it by removing the bracket that holds it. Working underneath a refrigerator is not complicated but it's awkward. The form of the new timer was not exactly the same, but it does function correctly. We have no experience whatsoever with appliance repair, so pretty amazed at our success. This old Amana looks very good inside and out and is now working perfectly again. If it lasts a few more years, we will be thrilled to have spent $15 to save $500. We can always buy new later on.
Parts Used:
Defrost Timer Kit - 120V 60Hz
  • Sharon from Champaign, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Outside of fridge around freezer was excessively hot
Research on the internet showed the problem was either the defrost thermostat or the defrost timer. I decided to replace both.

1. Emptied the freezer into an ice chest

2. Removed shelves, some of which were held in with screws.

3. Removed freezer back panel.

4. Replaced freezer thermostat, very simple, one clip and two wires.

5 Replaced all removed parts. Put food back in freezer

6. Removed and replaced defrost timer from underneath front of fridge, screws were awkward to reach.

7 No more heat around outside of freezer
Parts Used:
Defrost Timer Kit - 120V 60Hz Bimetal Defrost Thermostat
  • Barry from Altadena, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosted up quickly
I removed the panel in the back of the freezer and found the evaporator to be a complete block of ice. I defrosted it with a hairdryer. Following advice from the Partselect web site, I measured the resistance through the defrost heater. It was about 30 ohms, so I decided that it was OK. Next, I advanced the defrost timer manually with the compressor on until it turned off. The defrost heater did not operate. I concluded that the problem was the defrost thermostat. After installing it, the freezer worked properly.
Parts Used:
Bimetal Defrost Thermostat
  • James from Gulf Breeze, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker motor would run continuously but the blades would not turn and no ice came out.
I wasn't sure what the problem was, but the ice maker seemed simple and on-line resources suggested the control and motor assemblty was at fault. I searched the internet and Partsource had great diagrams which I could match to the part in hand. The price was right (way less than the local stores) so I ordered it.
I unplugged the unit from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
Parts Used:
Icemaker Control Assembly
  • Gary from Medway, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Grabbed the handle to open the door and it broke just above the bottom connectionbove the bottom connection.
Went online with Google, and located PartSelect. The locating of the part was simple, in that the instructions to find the part were very explicit.

After ordering the part, it arrived within two days. We were delighted!

Opening the box and seeing how well it was packed was gratifying. With a screwdriver the new handle had the name plate on, and screwed onto the door within 10 minutes.

It was a perfect fit, and a pleasure to have things in good shape again.
Parts Used:
Refrigerator Door Handle
  • David from Seatac, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door seals were badly distorted and did not seal in cold temperatures very well
I removes all food and drink items from the refrigerator and freezer doors. I then removed all of the screws holding the inner panel of the refrigerator door to the door itself. The old gasket could then be removed. I placed the new door gasket in place around the inner panel and reinstalled the inner panel with new gasket onto the refrigerator door. I then removed the inner panel from the freezer door and then removed the old gasket. I placed the new door gasket in place around the inner panel and reinstalled the inner panel with new gasket onto the freezer door. I used a portable drill with a 1/4 inch nut driver to remove and reinstall the many screws that held the inner panel and gasket on the doors.
Parts Used:
Freezer Door Gasket Refrigerator Door Gasket
  • victor from cheektowaga, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker leaked water
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Parts Used:
Replacement Ice Maker
  • Robert from Pennsylvania Furnace, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
didn't eject icecubes
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Parts Used:
Replacement Ice Maker
  • Ronald from Marion, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Parts Used:
Cycling thermostat
  • John from Rocky River, OH
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the seal on the gaskets were broken
Soaked the gaskets in bathtub to make them more pliable. They laid flatter and were easier towork with,
Parts Used:
Freezer Door Gasket Refrigerator Door Gasket
  • Barbara S. from Hendersonville, TN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not working
It turned out the water valve was not the problem but I think it works a bit better with the new one. I had replaced the main part of the icemaker inside the freezer which had lost the smooth finish in the ice tray. It worked for awhile but quit.
What had happened was the large approx. 1/2 inch tube going from the back of the refrigerator to the icemaker tray became plugged with ice. It was difficult to get it out due to the ice but once I did it was easy to melt it and put it back together. All's well that ends well and avoid the cost of a repair call. Working great now.
Parts Used:
Water Inlet Valve
  • Ron from Bartlett, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator worked, Freezer only getting to 29 degrees
Because the refrigerator worked (38-40 degrees) and the freezer only got down to 29 degrees, I thought that the freezer thermostat had gone bad. Changed it out but results are the same.
Parts Used:
Cold Control Thermostat
  • Kennith from Cincinati, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the BX22A2W