Models > 86120-2 > Instructions

86120-2 General Electric Freezer - Instructions

All Instructions for the 86120-2
1 - 15 of 56
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bulb had broken off in base that was still screwed into socket
At first I tried to use pliers to unscrew the base,very uncomfortable working position,upside down and backwards(the microwave is installed over the range top)very limited space for your body and arms to manuver and you really cant see the base,all of this took place after the breaker was turned off ofcourse,finally figured out that you can drop the entire bottom housing of the microwave by unscrewing 6 screws and the light sockets are easily accessable once you lower it,take out 1 retaining screw ,remove the entire socket and unscrewed the broken base and replaced the bulbs,I said bulbs,there is no sense in having to replace another bulb in who knows how long since only one had burned out but they were both the same age
Parts Used:
Light Bulb - 40W 130V
  • william from san antonio, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
92 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Parts Used:
Compressor Start Relay
  • Melvin from Semmes, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
79 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
buttom of refrigerator not cold
unplug it, pulled compressor start relay,which i thing it was the problem, but i replace bolt, very easy.
Parts Used:
Run Capacitor Compressor Start Relay
  • Giuseppe from brick, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
just quit working
Bought a new
capacitor.
Parts Used:
Run Capacitor
  • Denise from Lowell, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Changing the bulb that illuminates the cooktop
Loosen screw holding glass cover plate in place over bulb. Glass cover plate will swing down. Unscrew bad bulb, replace with good bulb, reset glass cover and tighten screw.
Parts Used:
Light Bulb - 40W 130V
  • LUCY from BALLWIN, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not freeze
unplugged, removed old parts, replaced with new
Parts Used:
Run Capacitor Compressor Start Relay
  • John from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped working, cooling.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Parts Used:
Compressor Start Relay
  • Jennifer from Jonestown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Parts Used:
Run Capacitor
  • Vicki from Johnson City, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Parts Used:
Run Capacitor
  • Frederic from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One end cap on freezer door broke.
First removed the remaining end cap; then inserted rod into RH and LH replacement caps and snapped end caps into place.
Parts Used:
End Cap Set - Includes Right and Left - White
  • judy from louisville, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mottor starts than stop.
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i found PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
Parts Used:
Compressor Start Relay
  • Gilmar from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer quit. Compressor would not start.
Like another post, the start relay rattled like a baby rattle. Replaced the start relay and freezer works great.
Parts Used:
Compressor Start Relay
  • Steve from Neosho, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and refrigerator stopped cooling
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Parts Used:
Run Capacitor
  • Amy from PITTSBURGH, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
under microwave (above stove) light
The replacement of the light no problem, the reason the light broke; problem. The original was glued in (for transport i think) and simply trying to unscrew it out (in a very tight slot) it broke; be careful or you’ll be buying a new $20 bulb (with shipping and handling).
Parts Used:
Light Bulb - 40W 130V
  • Bruce from Cleveland, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb burned ot
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
Parts Used:
Light Bulb - 40W 130V
  • John from Fort Smith, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 86120-2