Replacement of Coils
Removed by slightly wiggling out of the coupling. No tools needed, seriously, (and I'm a contractor). Basically, pull out and snap back in.
Parts Used:
Surface Element - 8 Inch - 2350W Surface Element - 6 Inch - 240V
  • Joseph from South Plainfield, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
35 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heating element required continuous adjustments to work.
I removed old 8" surface element and terminal block. Some of old wiring had to be cut off because of harding/cracking of old wiring. Stove was 23 years old and this burner was the most frequently used one. I soldered the new and remaining old wires together. I used the shirnk wrap that came with the terminal block to cover the solder joint. I screwed the new terminal block (one screw holds it in place - used same screw from old terminal block that was removed). I finished by inserting the new surface element. Everything works fine. In the next week or two after we use it a while, I will check wiring again to make sure there are no changes. You need to be very careful as it gets very hot under the burner.
Parts Used:
Surface Element - 8 Inch - 2350W Terminal Block
  • Richard from Apex, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
29 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Large burner would operate on high setting only.
1. Removed the back panel.
2. Disconnected the wires from the old switch while connecting wires to the new switch one at a time.
3. Installed the new switch and broke off the excess metal on the post which fits into the burner knob on front of the range.
4. Replaced the burner knob and replaced the back panel.
Parts Used:
INFINITE HEAT SWITCH KIT
  • Ernest from Bellevue, NE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had 2 of the terminals where the burner coil plugs into completely fry
First thing to do is to KILL THE POWER. The last thing you want is for two leads feeding power to a range coil burner "hot" when you are working on them. After power is off, I removed the coils and set them aside. The terminals had "fried" apparently from to much cooking with hot oils and having the "over splash" working its way down to where the coils plug into the terminals and over time the oil getting in the terminals causes shorting / frying of the leads / contacts.

Anyway, after removing the heat coils I removed the drip pans and cleaned up the area underneath before working on terminals. I like a clean area when I work. I then unscrewed the "brackets" that house the terminals with a Phillips screwdriver and pulled out the assembly.

To completely remove the assembly I cut with a straight razor the existing heat shrink around the wire nuts (These two had been replaced once before. On first go around, I just cut the terminal assembly off and stripped the wire to attach the new terminals). Then I removed the wire nuts and the old assembly. After that I trimmed the wire to the correct length on the new terminal assembly and checked that the wire from the stove was in good shape. Upon confirming I had a good lead, I connected the new terminal leads to the stove leads and put the heat shrink over the connections. I used a lighter to "shrink" the heat shrink to the new connection (not having a proper heat shrink gun, which most of us don't have, the lighter works well as long as you are careful and do not let the lighter heat up to much. Let the lighter cool (esp. if a plastic disposable type or it will melt and ruin the lighter or burn your fingers).

After that I cleaned the area where the terminal block bracket connects to the stove (it gets a bit gunked up over time) before screwing in the new bracket / assembly in place with my screwdriver.

I gave the drip pans a good cleaning, adjusted the new terminal brackets so they were even / centered, cleaned once more the area under the drip pan and replaced the drip pans. The types of pans I have are one piece with a hole for the heat coil leads to go through.

Before placing the coils back in the terminals I took a strip of medium grade, 220 grit, sand paper (you could use steal wool or small wire brush) and cleaned the terminal leads (the steal end that plugs into the terminal only, careful not to damage the burner). This was needed as the leads had accumulated some residue from the same dynamics that caused the burning / melting of the terminal leads and terminal block. Once the leads were clean I fitted them into the place in the new terminal blocks and drip pan grooves.

Finally I turned back on the breaker to the stove and cranked on the burners to test out the connection and that everything was working A-OK.

Job done:-)
Parts Used:
Terminal Block
  • PATRICK from WASHINGTON, DC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Swicth Stem Broken
Disconnect power. . . Remove control panel, pull wire connectors,[note location] remove old switch, install new, install wires, snip stem to length, set knob . . . Turn on power - works. [Note this is a live part even when not connected]
Parts Used:
INFINITE HEAT SWITCH KIT
  • FRANK from COPAKE, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Right front burner out.
Ever the optimist, I'd replaced the burner on this relic of another time to no effect. That left the switch. You guys should know that when a burner element goes bad it can take out the switch. I should have put a meter on it. Wehn I looked for a replacement a few months ago there were still factory parts available, but they were $80 or so and I wasn't inclined to risk that on a 40 year old range. I offered to replace the raange for my daughter as a Christmas present but she like this old thing. It was an unusual size with a pan storage compartment on the left. I went on line and found this universal replacement for about $25 delivered. What the heck. I ordered it and it arrived within a week. I pulled the stove out, killed the breaker, pulled the knob off, used a nut driver to take ther rear panel off, two phillips screws under the knob hold the switch in. The terminals on the old switch are in a slightly different order but are clearly marked L1, L2, H1, H2 and P. The P is the power and has a smaller terminal so you can't put it on the wrong one. Just examine the old switch ( it was marked the same way) take off the L1 and put in on the L1 of the new switch and so on, make sure you use the correct knob adapter to fit your old knob and break the switch stem to the correct length. It will break easilly if you hold it with one pliers and break it with another. Screw the new switch in place with he old screws. At this point, I closed the breakers and tested it. It worked fine. I turned the breakers off again. Buttoned it up and slid the stove back into place. 20 minutes tops. Great product. Good for another forty years.
Parts Used:
INFINITE HEAT SWITCH KIT
  • Larry from Prairie Village, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Electric Burner Control Broken
New one a little different ,but it was marked for wiring!
Had to install upside down because wires would not reach right side up!
Had to pull back side of knob out and turn 180 degrees and glue in knob, so knob would be right side up!
Works fine! Now all burners work again!
Parts Used:
INFINITE HEAT SWITCH KIT
  • Robert from VINELAND, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
infinite switch would not shut off at times.
First shut the power to the stove,then had to slide the stove out so I could get at the back to remove the panel screws.Once you have the back off remove the knob on the front.Under the knob is 2 phillips screws that you need to remove.Next I took the new switch and matched up the wires to the old switch.Reinstall is the reverse.Once the switch is in place you must remove the excess shaft to match the length of the old one.This is done with the use of 2 pliers,you grasp the shaft with both pliers and snap it off where you need it.The kit comes with spacers so you have got to match up the right one so the switch is solid on the shaft.This finishes the project,next turn the power back on and check that all is working ok.Job finished.
Parts Used:
INFINITE HEAT SWITCH KIT
  • Ervin from Milford, DE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Surface Burners were very slow.
Removed old surface burners and replaced them by plugging in the new surface burners. Now they work GREAT! Parts ordered and received with-in 3 business days. Fed EX delivered parts in good order very quickly. We recommend PartSelect.com
Parts Used:
Surface Element - 8 Inch - 2350W Surface Element - 6 Inch - 240V
  • Fisher from Fort Collins, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Surface element was corroded.
Removed existing surface element and replaced with new element.

P.S.

Part Select service was excellent.
Parts Used:
Surface Element - 8 Inch - 2350W
  • Paul from Southern Pines, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old infinite switch WB21X36771 broke...heating element stopped heating
1. Bought replacement part said to replace old switch.
2. Pulled old switch out.
3. Replacement part did not match. Would have to take entire switch panel apart to change to this part.
4. Multiple-part instructions very poor. For my switch unreadable.
5. Old part was "push to turn". New part was not.
6. Knob did not fit new switch. Old shaft was "D" shaped. New is square.
7. Gave up. Need to call repair shop.
8. Hope this helps.
Parts Used:
INFINITE HEAT SWITCH KIT
  • Richard from PLANO, TX
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
pans were corroded
Unplugged the elements and removed the corroded drip pans and replaced them with the the new ones, which fit perfectly.
Parts Used:
Drip Bowl - 8 Inch Drip Bowl - 6"
  • Dorothy from Gladwin, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
melted electric range element
Because of the superb pics and descriptions on the Part Select site, I was able (with NO range model number) to order the correct range element for beloved son's stove. He plugged it in in 3 seconds, works great !
Parts Used:
Surface Element - 8 Inch - 2350W
  • Carole from Cleveland, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed to replace a receptacle
I had already removed the worn out part. The new part came with wire joint covers and connecting them was fine. The brace that came with the part did not actually fit onto the stove burner well; so I cleaned and used the older brace - but, when I went to put it back in place, the bearings on the original self locking bolt were stripped. So, I had to find a replacement bolt with a nut. Found that I had some of those on hand. Once the brace was firmly in place, the rest was easy!
Parts Used:
Terminal Block
  • Mary Catherine from silver spring, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
5 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
terminal block not working
simple remove the old one, strip old wires to make longer, twist wires together, put on wire nuts.
Parts Used:
Terminal Block
  • JAMES from SAN JOSE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
2 of 2 people found this instruction helpful.