No heat to dry clothes
First I took the front of the dryer off then located the igniter. It only required removing two screws, removing old igniter, replacing with new igniter, and replacing the two screws.. While I was replacing the igniter I took the drum out and throughly cleaned the inside. Lucky me, I found 85 cents on the floor of the dryer. I am 65yrs old, married and mother of two. This was easy to do and sure saved money. I reccommend others try to do repairs for themselves and using PartSelect was less expensive too.
Received conversion kit. Removed front dryer panel,2 screws. Removed burner tube, 2 screws then removed natural gas orfice. Installed propane orfice and repalced burner tube. Removed regulater plug and replaced with new plug from kit using 90 degree ratchet screw driver. Approximately 20 minutes. Dryer working great.
the problem was not the igniter its was the thermal fuse I broke the igniter during inspection of the problem be careful its a very easy thing to break repairs complete thank you parts select for the quick shipping and low prices
Our dryer would not heat and it seemed that no gas was coming from the regulator. The igniter was working fine but the burner never turned on. To check the problem, i followed the instructions to remove all body panels until I had access to the burner assembly. I dismantled both gas valve coils and tested each one for open or closed circuit using my multi-tester. I found that the three terminal gas valve coil was an open circuit and was not functioning so I ordered a new one from PartSelect and within just a couple days, had the drier back up and functioning. I also replaced the igniter due to a malfunctioning igniter that has been changed by the manufacture. I must say that PartSelect has the fastest shipping I have ever seen. One part I ordered was at my door in less than 24 hours and I only paid standard shipping...un real! OUTSTANDING....5 STAR SERVICE
Initially we thought the problem was the igniter, so we ordered an igniter kit. Installed it but was unsuccessful. We then went on the websight and read further, about 50% of dryers with no heat but working had a problem with the thermal fuse.So we ordered the thermal fuse installed it, which was very easy, and success. Once the problem was diagnosed properly it was fast and easy. Recommend looking at the statistics for specific problem.
Well, here's the rub...in order to find out what part I needed to order, I needed to take the dryer apart to where the gas controls are, and there on a sticker was a part number for an LP conversion kit. But, in order to get to that gas valve unit, I fumbled about figuring out how to take this brand new dryer apart, since there were absolutely no instructions whatsoever in the owners manual. And once apart, and pretty much all apart, I wondered how it would be that the Maytag repair man would be so lonely, as he'd have plenty to do. However, the kit had great instructions as to how to take it apart and change out the orifices.
removed front of dryer located igniter removed two screws disconnected wires then put new one in also replace thermal fuse and thermostat on back of dryer works great.
For the Ignitor - As involved as taking the dryer completely apart sounded, it was super easy. 1-take out the lint trap and remove the two screws there. 2-Pop open the top with a screw driver and swing the top completely over/back. 3- remove the two screws holding in the front panel and remove the panel. 4- loosen the belt by pushing on the tension roller under the drum on the right and remove the drum (its super light) use the belt as a handle. 5- remove the screw holding in the ignitor and replace it with the new one. Be careful to not touch the new ignitor. Then go backwards putting it back together.
No heat, would not light because igniter burnt out
Unplug dryer. Remove the front bottom panel of dryer 2 screws, then unplug wire connector to the old igniter then unscrew one screw holding ignitor then wiggle out. Open new igniter wiggle back in place insert screw tighten, (getting this screw back in is a little hard) replug wire connector to new igniter replace front panel with two screws. Plug in dryer and there you go drying clothes again. Wife all happy again.
Thermal fuse was blown so I replaced it. Still no heat. Hi-Limit thermostat and Cycling Thermo. had continuity as did flame sensor. Igniter tested 66ohms. I placed a wire jumper across the Hi-Limit and the igniter glowed, solenoids opened and gas came on. I orderd the Hi-Limit and since both "overheating" limiters were defective I decided to order the cycling thermo just in case. The Hi-Limit was received in 2 days but the Cycling Thermo was backordered. In the meantime my wife got antsy so I went ahead and installed the Hi-Limit and put her back in service... ...for one load. I wasn't certain if I had fried the "limiters" again but since they had continuity and I could measure continuity all the way to the Igniter I decided that it HAD to be the cause. I ignored the flame sensor since it never came into play without the igniter glowing... The igniter arrived and measured 56ohms. Hmmm... After installing the problem was solved. Word of advice: If the thermal fuse is blown and even if all else in the circuit SEEMS ok, go ahead and order the Fuse, Hi-Limit and Cycling Thermos, and the Igniter. It will take you about 30 minutes to install and you'll reduce your out-of-service time! Good luck!
Dryer had no heat at all. This is an older gas dryer.
Cleaned out years of fuzz behind lower access panel and noticed where the igniter sits there is a metal tube about 1 inch in diameter. It had rust on the end and was starting to flake away. Found some helpful hints about how to test the igniter. Very easy, just used an ohmeter. Unplugged the 2 pin wire connector and checked for continuity. 1 lead on 1 pin and the other on the other pin., igniter side not the harness side from the dryer. A good igniter should read less than 5 ohms. I don't know the spec. exacttly, but it should not read open or infinite resistance. My meter read an open circuit. Removed the tube and igniter assembly, mine only 2 small bolts. I found the igniter element cracked. Ordered and installed igniter and tube assembly. This was a very easy install. 20 year old dryer works great and it's better than spending $500.00+ on a new one.
After opening the bottom access panel, I found a lot of lint build up which is very flammable. I took my leaf blower and cleaned it all out. Then I just followed the instructions that came with the part. But be careful as the igniter is fragile. I broke the first one...