Models > 106R14FL3 > Instructions

106R14FL3 Kenmore Refrigerator - Instructions

All Instructions for the 106R14FL3
1 - 3 of 3
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Both outside door handles turned very beige
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
Parts Used:
Spray Paint - 12 oz. - White
  • Howard from Boynton Beach, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
22 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator coils would freeze up solid
Removed everything from inside freezer compartment (food and shelves) Removed inside backpanel that covered the coils. At the top of the coils is where the thermostat was attached. Removed old one and installed new. Has been working since.
Parts Used:
Defrost Thermostat
  • Walt from Sutter, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not cooling
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Installing it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Parts Used:
Defrost Thermostat
  • John from Niles, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 106R14FL3
1 - 3 of 3