This fuse, also known as a cartridge fuse, is a genuine OEM replacement part for microwaves. It has a glass cylindrical body with a metal cap on each end. The cap connects the fuse to the circuit. If ...
This door latch keeps the microwave door closed during operation. The latch is approximately 7 inches long and has 2 hooks to ensure that the door closes properly. The hooks also contact the door swit...
This light bulb is for microwaves.
Light bulb illuminates the surface below the microwave or the interior of the microwave.
Because high-voltage capacitors in a microwave can retain a lethal e...
This OEM waveguide cover in your microwave is a heat-resistant component that prevents food, grease, and moisture from entering the waveguide. It is typically located on the side or top wall of the co...
Sold individually. This grease filter is for microwaves.
Grease filter traps grease from the exhaust air.
Follow the instructions in the owner's manual when installing this part.
Sold individually. Product Description Charcoal air filter works with some Frigidaire, Electrolux, White Westinghouse, and Tappan models of microwaves. This is a genuine OEM part that works for some m...
This door switch is designed for use with various makes and models of microwaves and is a genuine OEM part. This individually sold switch connects to the frame of the microwave through the door switch...
Ask our experts a question about this model and we'll get back to you as soon as possible!
4 questions answered by our experts.
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Tom
January 26, 2020
Turn microwave on
Kicks breaker off on breaker box
For model number FGMV154CLFA
Hello and thank you for writing.
The microwave is overloading the electrical circuit. In other words, the circuit is rated to handle a certain amount of amps (unit of electrical current), and the microwave is exceeding that amount, causing the breaker to trip. The microwave is malfunctioning and pulling too much electrical current. It certainly sounds like you might need to replace the line fuse PS5136235. We hope this helps. Please contact us anytime if you require further assistance.
A lot of moisture forms on the kitchen cabinets, above the microwave when using it to cook anything. If i use the "fan" button moisture does not form. This is an externally vented microwave. I have never had a microwave do this before ever. What is up?
For model number FGMV154CLFA
Hello Steven,
Thank you for your question. This is normal for your microwave, the fan is able to prevent moisture from forming before it is stuck on your cabinets. We hope this helps.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Roy
July 5, 2021
I need machine screws (3) 1/4”-28x31/4” to mount microwave under cabinet. Is this something you have available?
For model number FGMV154CLFA
Hello Roy, Thank you for contacting us. We have researched the model you have provided and have found the part you are looking for is PartSelect Number PS1993479. We looked up the part and it is listed as No Longer Available/Discontinued sorry. There are no part substitutions listed. Our suggestion here would be to call the manufacturer and see if they can provide you with a substitution for these part numbers and contact us back with he updated substitution number. We hope this helps!
1 person found this helpful.
Was this helpful?
Thank you for voting!
John
August 18, 2021
The illumination lamp on the right side blinks after being on for a min or so. The blinking accelerates more frequently until i turn it off. Any ideas?
For model number FGMV154CLFA
Hello John, Thank you for writing. This sounds like you will need to have the bulb replaced. Light Bulb PartSelect Number PS1765541 illuminates the surface below the microwave. Because high-voltage capacitors in a microwave can retain a lethal electrical charge even when the microwave is unplugged, a service technician should install this part unless the owner's manual includes instructions for installing the light bulbs. Good luck with your repair.
Remove vent cover then remove touch screen control panel. When you remove control panel take photo of where everything is plugged in then unplug and remove control panel. 3 door switches located next to door in a plastic chassis. Test each switch with current tester. Remove the bad switch and replace with the new one. You tube DIY helped.
First thing I dir was search YouTube for any related videos and found this one https://www.youtube.com/watch?v=uHj4H9Fdxrc, it was the exact problem my microwave was exhibiting. Once I verified the problem by troubleshooting, I removed the part and verified that the switches were working fine, the door latch assembly showed signs of wear
... Read morewhich was the cause of the problem. After receiving the replacement part I installed it, verified that power was restored to the unit and reassembled the microwave, works fine, hope it lasts a long time!