This water inlet valve (Refrigerator Water Inlet Valve Assembly) supplies water to the ice maker and the water dispenser in your refrigerator. It is located at the back of the fridge, beneath the bottom panel. It is connected directly to 2 water supplies, a wiring harness, and your inlet water tube. This part is located at the back of the fridge, beneath the bottom panel. It is connected directly to 2 water supplies, a wiring harness, and your inlet water tube. Minerals and sediments can build up over time and cause a blockage in your inlet valve. They can also cause the valve to stick open, leading to an overflow of water. If this part is malfunctioning, water flow to your appliance could be compromised. Check for small ice cubes or a lack of ice cubes/water, as this is an obvious sign the part is damaged. The water inlet valve must be replaced if the solenoids no longer have continuity or the valve has internal blockage. Test your water inlet valve with a multimeter. You can test both the water dispenser side and the ice maker side. The part measures approximately 3 inches long and 2.75 inches wide and is constructed of plastic and metal. This replacement part features 1 dual inlet water valve with quick connections. It also has 1/4 and 5/16 John Guest fittings for the outlet lines and a 1/4 compression fitting for the inlet line.
Fixes these symptoms
- Ice maker not making ice
- Ice maker won’t dispense ice
- Leaking
- See more...
Installation Instructions
ralph from bristow, VA
Refrigertor water dispenser not working BUT ice machine is working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo the connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refreigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explantion. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call which can now be used to take the family to dinner after your "exhausting" 15 minute workout of removing about 10 screws and wheeling the unit in and out of place. Writing this article took longer! My 4 year old worked harder holding the flash light!
Read more...
General Electric Refrigerator Water Inlet Valve
PartSelect Number PS12727426
Manufacturer Part Number WR57X30890
This water inlet valve is sourced directly from the manufacturer to ensure the best fit with your refrigerator. The water inlet valve is responsible for controlling the flow of water into the water dispenser and ice maker. It is typically located at the back of the refrigerator and is connected to the household water supply line. It opens to allow water to flow into the refrigerator and once the desired amount of water has been dispensed or the ice maker water reservoir has been filled, the valve closes to stop the flow of water. The water inlet valve will need to be replaced if it is physically damaged or otherwise faulty.
Fixes these symptoms
- Ice maker not making ice
- Not dispensing water
- See more...
Installation Instructions
Christopher from BANCROFT, MI
No water and no ice being made
Checked to make sure water was going to the fridge and it was. Removed the 1st line after the valve and no water was present. Figured the valve was bad. Removed the wires to the old valve and also had to remove the wire harness on the new valve. It wasn't needed. Replaced the valve and installed the old wires. Hooked up the water line and instantly had water. A day later I had a full ice bucket. This part wasn't listed on GE website. But it was on partselect.com.
Read more...
General Electric Refrigerator Water Valve And Tube Asm
PartSelect Number PS16660052
Manufacturer Part Number WR57X39965
Installation Instructions
John from CLARK MILLS, NY
Water valve was not working
Unplugged the unit took out valve and water line put new valve and water line back just the way it was in 45 min had ice cubes being made no leaks
Read more...
Your Price
$68.11
In Stock
General Electric Refrigerator Water Valve
PartSelect Number PS1483564
Manufacturer Part Number WR57X10070
This part releases water from the supply line when it's activated.
Fixes these symptoms
- Ice maker not making ice
- Leaking
- Not dispensing water
- See more...
Installation Instructions
Dennis from MARTINSBURG, WV
No water from the dispenser and Water leaking on floor
I searched YouTube for the problem and was quickly taken to several videos that detailed to required actions. This encouraged me to proceed, so I took the back cover off and found the water valve leaking. I then googled the make and model of the frig and found the part. The YouTube videos provided all of the details needed to determine the problem and replace the faulty part. Once the part arrived, I was able to install the new one in a few minutes. Operation returned to the water dispenser and the leak was gone. Total cost of the repair was $56 and took about 1.5 hours to remove the original part, order the replacement and install it when it came. Perfect!
Read more...
Your Price
$58.51
In Stock
General Electric Refrigerator Dual Inlet Water Valve
2. Remove water line to valve. Watch for water to pour out of the line. Have a towel handy.
3. Remove the cardboard cover on the bottom of the fridge.
4. Remove the screws that hold the valve in place.
5. Remove the valve, be careful the waterlines are still attached.
6. Place a towel under valve to catch any water that leaks out from water lines.
7. Remove electrical lines, make sure to mark which went where. One is for the ice, and one is for the water. Make sure the power is off, there is 120 volts present at those connections.
- now my waterlines attached using a compression type fitting. The new valve I got used just a push in type of attachment. But, easy enough I just removed the pieces for the compression and the waterlines pushed right in and worked fine.
- the mounting harness for the valve was alittle different but the parts I need were in the right location and she fit in fine.
8. Attach water lines. They are different sizes so you can't get those mixed up.
9. Attach electrical lines.
- the new valve came with adaptors for my electrical connection. Just snapped them on and kept on going.
10. turn on watersupply for fridge. Plug it back in.
11. Test for leaks, and proper operation. ie. When you push the water does the water valve open?
12. Unplug fridge
13. Now is a good time to clean out any dust or dirt that has accumallated in under around your fridge.
14. reassemble, valve, then cover. move fridge back into place.
15. Plug fridge back in.
16. Take a clean glass.
17. Fill with water from the front.
18. Take full glass of water and go watch tv. You've earned it, and saved yourself probably $100.00 in labor costs. Good Job. Read more...
PartSelect Number PS901314
Manufacturer Part Number WR57X10051
This valve comes with 1/4" compression inlet.
NOTE: This part comes with new quick connections. To install - cut retaining nuts off of existing plastic water lines and gently push them into new valve. To remove - depress ring that the tube slides into.
Fixes these symptoms
- Ice maker not making ice
- Ice maker won’t dispense ice
- Leaking
- See more...
Installation Instructions
anthony from thornton, CO
Cracked housing on the vaave
1. Turn off water supply, and electrical ( unplug it) to fridge.2. Remove water line to valve. Watch for water to pour out of the line. Have a towel handy.
3. Remove the cardboard cover on the bottom of the fridge.
4. Remove the screws that hold the valve in place.
5. Remove the valve, be careful the waterlines are still attached.
6. Place a towel under valve to catch any water that leaks out from water lines.
7. Remove electrical lines, make sure to mark which went where. One is for the ice, and one is for the water. Make sure the power is off, there is 120 volts present at those connections.
- now my waterlines attached using a compression type fitting. The new valve I got used just a push in type of attachment. But, easy enough I just removed the pieces for the compression and the waterlines pushed right in and worked fine.
- the mounting harness for the valve was alittle different but the parts I need were in the right location and she fit in fine.
8. Attach water lines. They are different sizes so you can't get those mixed up.
9. Attach electrical lines.
- the new valve came with adaptors for my electrical connection. Just snapped them on and kept on going.
10. turn on watersupply for fridge. Plug it back in.
11. Test for leaks, and proper operation. ie. When you push the water does the water valve open?
12. Unplug fridge
13. Now is a good time to clean out any dust or dirt that has accumallated in under around your fridge.
14. reassemble, valve, then cover. move fridge back into place.
15. Plug fridge back in.
16. Take a clean glass.
17. Fill with water from the front.
18. Take full glass of water and go watch tv. You've earned it, and saved yourself probably $100.00 in labor costs. Good Job. Read more...
Your Price
$72.91
In Stock
General Electric Refrigerator Water Inlet Valve - 120v 60hz
PartSelect Number PS11743551
Manufacturer Part Number WP67003753
The water inlet valve is a solenoid-operated switch that, when activated, releases water from the supply line to the water valve and into the compact icemaker mold. This valve is used on side by side or bottom mount refrigerators.
Fixes these symptoms
- Ice maker not making ice
- Ice maker won’t dispense ice
- Leaking
- See more...
Installation Instructions
Bruce from Biddeford, ME
Ice maker not working
The initial problem was that the ice maker was not working. I had the unit repaired at a local store and they assured me that it worked fine in their workshop. I believed that the valve was the next logical part to replace. The installation was very easy. I unplug the refrigerator and turned off the water. Removed two, easily reached, screws and pulled the unit out. Disconnected the wire harness (you may want to mark the top of the wire harness before removing for immedite alignment on reassembly) and tubing. Notice a spot in the tubing that had been kinked, so cut that out. Reassemble and turned everything back on. Installation went perfectly. Unfortunately, I still do not have ice and will be doing some additional trouble shooting to determine the next course of action. I may be in touch.
Read more...
General Electric Refrigerator Valve & Guard Assembly
PartSelect Number PS11767935
Manufacturer Part Number WR57X26303
General Electric Refrigerator Single Outlet Valve Kit
PartSelect Number PS304375
Manufacturer Part Number WR57X10033
The water inlet valve on your refrigerator allows water to enter the ice maker and water dispenser. If your ice maker or water dispenser is not functioning properly, or you notice a leak, you may need to replace the single outlet valve. This single outlet valve has 1/4-inch compressions fittings and is intended for use with refrigerators that make crescent-shaped ice cubes. As per the manufacturer, this valve has a new quick connection. You must cut the retaining nut off your current plastic water line, and gently push it into the new valve. Be sure to disconnect the water and power sources from the refrigerator before you begin this repair.
Fixes these symptoms
- Ice maker not making ice
- Ice maker won’t dispense ice
- Leaking
- See more...
Installation Instructions
Michael from Bradenton, FL
ice maker not working properly and door seal worn
Two screws held the icemaker on. You do not even have to take them all the way out to remove the IM. Replacement of the water valve was just as easy except they (parts manufacturer) updated the flange nut with a compression fitting and it took me a minute looking at it before I realize what was going on. The door seal could not be easier, no tools just a few minutes of time
Read more...
General Electric Refrigerator Water Valve
PartSelect Number PS12744136
Manufacturer Part Number WR57X32213
General Electric Refrigerator Secondary Dual Water Inlet Valve
PartSelect Number PS6011774
Manufacturer Part Number WR57X10098
Fixes these symptoms
- Not dispensing water
- See more...
Related General Electric Refrigerator Parts
- All General Electric Refrigerator parts
- General Electric Refrigerator Brackets and Flanges
- General Electric Refrigerator Caps and Lids
- General Electric Refrigerator Circuit Boards and Touch Pads
- General Electric Refrigerator Compressors
- General Electric Refrigerator Dispensers
- General Electric Refrigerator Door Shelves
- General Electric Refrigerator Doors
- General Electric Refrigerator Drawers and Glides
- General Electric Refrigerator Drip Bowls
- General Electric Refrigerator Ducts and Vents
- General Electric Refrigerator Elements and Burners
- General Electric Refrigerator Fans and Blowers
- General Electric Refrigerator Filters
- General Electric Refrigerator Grates
- General Electric Refrigerator Grilles and Kickplates
- General Electric Refrigerator Handles
- General Electric Refrigerator Hardware
- General Electric Refrigerator Hinges
- General Electric Refrigerator Hoses and Tubes
- General Electric Refrigerator Ice Makers
- General Electric Refrigerator Knobs
- General Electric Refrigerator Lights and Bulbs
- General Electric Refrigerator Motors
- General Electric Refrigerator Panels
- General Electric Refrigerator Power Cords
- General Electric Refrigerator Seals and Gaskets
- General Electric Refrigerator Springs and Shock Absorbers
- General Electric Refrigerator Switches
- General Electric Refrigerator Thermostats
- General Electric Refrigerator Trays and Shelves
- General Electric Refrigerator Trims
- General Electric Refrigerator Wheels and Rollers