This three-terminal switch fits your microwave door. This part is mostly black in color and is about 1.5 inches with metal terminals. You might need to replace this part if your microwave is not heating properly or if it runs for a few seconds but turns off.
This three-terminal switch fits your microwave door. This part is mostly black in color and is about 1.5 inches with metal terminals. You might need to replace this part if your microwave is not heating properly or if it runs for a few seconds but turns off.
What this part fixes:
  • Doesn’t shut off
  • Door not closing properly
  • No heat
Installation Instructions
Mark from HOMER GLEN, IL
Door switch inconsistent operation for Open/Close sensing.
Ordered top & bottom micro-switches and mounting plate parts. Internet reviews could not find specifics if the issue was due to a top/bottom or combination of micro-switch or mounting plate failure. Pulled the plug. Removed the top vent assembly cover held in by 2 Phillips screws inside the vent. Removed the control panel held in by 1 Phillip screw at the top vent assembly area. Lifted control panel upward to release the catch and moved it off to the side - didn't disconnect any leads. Used a Torx bit to remove the door switch mounting plates at the front and pulled the plates through the opening from the control panel. Documented the wire color code connections, the top plate uses 2 micro's with one using both the closed & open contact. Installed the respective micros on the mounting plates and worked backwards with the wiring and removal steps. Once completed, the open/close sensing has worked every time.
This door interlock switch is a genuine replacement part designed for use in microwaves. It serves a critical safety function by preventing the microwave from operating when the door is open. Because proper operation of the microwave’s shielding and interlock system is essential for user safety, this part should be installed by a qualified service technician. After installation, the interlock switches and microwave shielding must be thoroughly tested to ensure the appliance meets safety standards.
This door interlock switch is a genuine replacement part designed for use in microwaves. It serves a critical safety function by preventing the microwave from operating when the door is open. Because proper operation of the microwave’s shielding and interlock system is essential for user safety, this part should be installed by a qualified service technician. After installation, the interlock switches and microwave shielding must be thoroughly tested to ensure the appliance meets safety standards.
What this part fixes:
  • Doesn’t shut off
  • Door not closing properly
  • No heat
Installation Instructions
Mark from HOMER GLEN, IL
Door switch inconsistent operation for Open/Close sensing.
Ordered top & bottom micro-switches and mounting plate parts. Internet reviews could not find specifics if the issue was due to a top/bottom or combination of micro-switch or mounting plate failure. Pulled the plug. Removed the top vent assembly cover held in by 2 Phillips screws inside the vent. Removed the control panel held in by 1 Phillip screw at the top vent assembly area. Lifted control panel upward to release the catch and moved it off to the side - didn't disconnect any leads. Used a Torx bit to remove the door switch mounting plates at the front and pulled the plates through the opening from the control panel. Documented the wire color code connections, the top plate uses 2 micro's with one using both the closed & open contact. Installed the respective micros on the mounting plates and worked backwards with the wiring and removal steps. Once completed, the open/close sensing has worked every time.
What this part fixes:
  • Door not closing properly
  • Won’t turn on
Installation Instructions
LARRY from PARKERSBURG, WV
Microwave would say open and close door.
Removed panel and installed upper and lower switches. I did this because it did not do it all the time. When I removed the switches I used a ohms meter to check continuity but they all checked out at first then I started playing around with the buttons on each switch by pushing in on them and letting off and found one when you pushed in and out three or four times that one switch would jump back and forth by ohms meter that was the bad switch. If any one else has that problem the switch might show continuity when you first test but click the switch button a few times to see if you get a different reading. Microwave up running. Thanks Partselect.
This door switch, also known as a safety switch, is a genuine OEM replacement part for microwaves. It is a safety mechanism that sends signals to the microwaves control system, telling it when the door is open/closed. This ensures that the microwave only operates when the door is securely shut and switches off as soon as the door is open. Over time, this switch can become worn out or damaged. A faulty door switch can result in failure to switch the microwave on/off, lack of heat, and running with the door open. To confirm that the door switch is faulty, use a multimeter to test for electrical failure. To remove the faulty switch, disconnect the wiring connectors and take note of where they are positioned. Place the new switch in position and reattach the wiring connectors to the appropriate terminals and close the microwave door to check that the switch engages appropriately.
This door switch, also known as a safety switch, is a genuine OEM replacement part for microwaves. It is a safety mechanism that sends signals to the microwaves control system, telling it when the door is open/closed. This ensures that the microwave only operates when the door is securely shut and switches off as soon as the door is open. Over time, this switch can become worn out or damaged. A faulty door switch can result in failure to switch the microwave on/off, lack of heat, and running with the door open. To confirm that the door switch is faulty, use a multimeter to test for electrical failure. To remove the faulty switch, disconnect the wiring connectors and take note of where they are positioned. Place the new switch in position and reattach the wiring connectors to the appropriate terminals and close the microwave door to check that the switch engages appropriately.
What this part fixes:
  • Doesn’t shut off
  • No heat
  • Won’t turn on
Installation Instructions
Lynn from LOUISVILLE, KY
Microwave would not start when door closed. Sometimes you could push in or jiggle door and it would work for awhile and then it woud stop again. I knew it eas a door switch issue but wasn't certain which of the 3 or the body latch itself.
I removed the body latch assembly and found the bottom micro switch (NC) terminal burnt and loose. I replaced and working perfectly fine now. Easy diagnose and easy repair.
This microwave door interlock switch is a critical safety component designed to prevent the appliance from operating when the door is open. It functions by detecting the door’s position—open or closed—and relaying this information to the microwave’s electronic control system. This ensures the unit only activates when the door is securely latched. Commonly used in microwave models experiencing issues such as failure to start or lack of heating, the switch plays a vital role in maintaining safe operation. Installation involves accessing the internal door latch mechanism and replacing the switch, which typically requires basic tools and careful handling to avoid damage to surrounding components. The switch is compact and designed to fit seamlessly within the microwave’s door assembly.
This microwave door interlock switch is a critical safety component designed to prevent the appliance from operating when the door is open. It functions by detecting the door’s position—open or closed—and relaying this information to the microwave’s electronic control system. This ensures the unit only activates when the door is securely latched. Commonly used in microwave models experiencing issues such as failure to start or lack of heating, the switch plays a vital role in maintaining safe operation. Installation involves accessing the internal door latch mechanism and replacing the switch, which typically requires basic tools and careful handling to avoid damage to surrounding components. The switch is compact and designed to fit seamlessly within the microwave’s door assembly.
What this part fixes:
  • Door not closing properly
  • Won’t turn on
Installation Instructions
E G from SILVERDALE, WA
The display kept asking me to close the door, even though the door was closed. The interior light stayed on.
I used a Google search to show how to access the area behind the front panel. There was a folded paper copy with a schematic and wiring diagram in that space.Then I used a multi-meter to determine which of the THREE micro-switches was causing the problem. I called your help line and ordered a replacement switch. The switch was delayed in transit so your agent credited me with the cost of shipping.

When the part arrived, it had three terminals instead of two as shown in the on-line picture but that did not cause any difficulty in using it. It took about 20 minutes to remove and replace the old switch.

All seems to be working well now.

Finding which of the THREE switches was the problem was the most difficult part of the repair. All three "clicked" but the defective one did not click as easily. It needed to be depressed more than the door latch can would provide. Old age?
Original Equipment Manufacturer

MAKE THIS REPAIR A GUARANTEED WIN

OVER 2 MILLION PARTS TO ENSURE VICTORY

This microwave door interlock switch responds to the door latch, helping prevent cooking operation while the door is open. Its small actuator changes the electrical contact when the door opens or closes. A worn or damaged switch may prevent the microwave from starting even when the door is fully shut. Replacing a faulty switch helps restore proper door detection within the safety interlock system. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
This microwave door interlock switch responds to the door latch, helping prevent cooking operation while the door is open. Its small actuator changes the electrical contact when the door opens or closes. A worn or damaged switch may prevent the microwave from starting even when the door is fully shut. Replacing a faulty switch helps restore proper door detection within the safety interlock system. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
What this part fixes:
  • Doesn’t shut off
  • No heat
  • Tray won’t turn
Installation Instructions
Joshua from WHITE LAKE, MI
Microwave would not rotate or heat up food.
After watching a few youtube videos, I used a phillips SD to take controll pannel off to access the switches that sense when microwave door is closed. Swapped out all 3 switched and mocrowave works like new. $20 fix (shipping included)
What this part fixes:
  • Doesn’t shut off
  • Door not closing properly
  • Won’t turn on
Installation Instructions
Mark from HOMER GLEN, IL
Door switch inconsistent operation for Open/Close sensing.
Ordered top & bottom micro-switches and mounting plate parts. Internet reviews could not find specifics if the issue was due to a top/bottom or combination of micro-switch or mounting plate failure. Pulled the plug. Removed the top vent assembly cover held in by 2 Phillips screws inside the vent. Removed the control panel held in by 1 Phillip screw at the top vent assembly area. Lifted control panel upward to release the catch and moved it off to the side - didn't disconnect any leads. Used a Torx bit to remove the door switch mounting plates at the front and pulled the plates through the opening from the control panel. Documented the wire color code connections, the top plate uses 2 micro's with one using both the closed & open contact. Installed the respective micros on the mounting plates and worked backwards with the wiring and removal steps. Once completed, the open/close sensing has worked every time.
This part is a genuine manufacturer door interlock switch kit, also known as primary micro switch or microwave switch kit, for a microwave. The function of this part is to sense when the door of the microwave is open or closed. If the part is defective, the microwave will not start or will start when door is open. This kit contains two 15 Amp, 125/250 Volt switches with 3/16 inch terminals. Be sure to disconnect power to microwave before replacing part. Use extreme caution when replacing microwave parts, as high-voltage capacitors can retain an electrical charge when unplugged. NOTE: This kit includes 2 single pole, double throw (SPDT) micro switches. As per the manufacture for the secondary interlock switch order part # 56001100.
This part is a genuine manufacturer door interlock switch kit, also known as primary micro switch or microwave switch kit, for a microwave. The function of this part is to sense when the door of the microwave is open or closed. If the part is defective, the microwave will not start or will start when door is open. This kit contains two 15 Amp, 125/250 Volt switches with 3/16 inch terminals. Be sure to disconnect power to microwave before replacing part. Use extreme caution when replacing microwave parts, as high-voltage capacitors can retain an electrical charge when unplugged. NOTE: This kit includes 2 single pole, double throw (SPDT) micro switches. As per the manufacture for the secondary interlock switch order part # 56001100.
What this part fixes:
  • Doesn’t shut off
  • No heat
  • Won’t turn on
Installation Instructions
Robert from Bainbridge Island, WA
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
This part keeps the microwave from running when the door is open.
This part keeps the microwave from running when the door is open.
What this part fixes:
  • Door not closing properly
  • Won’t turn on
This micro switch is used in selected Samsung microwave door and safety circuits to signal whether the door mechanism is in the required position. If the microwave will not start or behaves inconsistently, the switch and latch alignment may need testing. Microwave high-voltage components can remain hazardous after unplugging, so use qualified service.
This micro switch is used in selected Samsung microwave door and safety circuits to signal whether the door mechanism is in the required position. If the microwave will not start or behaves inconsistently, the switch and latch alignment may need testing. Microwave high-voltage components can remain hazardous after unplugging, so use qualified service.
What this part fixes:
  • Doesn’t shut off
  • Won’t turn on
Installation Instructions
Lynn from LOUISVILLE, KY
Microwave would not start when door closed. Sometimes you could push in or jiggle door and it would work for awhile and then it woud stop again. I knew it eas a door switch issue but wasn't certain which of the 3 or the body latch itself.
I removed the body latch assembly and found the bottom micro switch (NC) terminal burnt and loose. I replaced and working perfectly fine now. Easy diagnose and easy repair.