- Home
- TBX25FPLLAD
- Instructions
TBX25FPLLAD General Electric Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Water valve for ice maker leaking
3 of 5 people
found this instruction helpful.
-
Randall from Cumming, GA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Wrench set
Other than having to bend the bracket 90 degrees it was an easy install.
Was this helpful?
Thank you for voting!
ice bucket and auger assembly did not work
2 of 2 people
found this instruction helpful.
-
Gil from Nashua, NH
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Found your web site and bought a couple of replacement parts from you guys and reaaembled unit. Its now working. Only issue I had was in the reassembly of the auger unit, wasn't quite sure of the blades etc. and the proper order Saw the sketch on your site and figured it out from that. Will visit you guys again when I need a part. Good
... Read more
delivery and timely. Thanks and regards Gil
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer too cold and refrigerator not cold enough because fan not working
2 of 2 people
found this instruction helpful.
-
Ann from LAPORTE, PA
- Easy
- 30 - 60 mins
-
Nutdriver
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and r ... Read more ed wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and r ... Read more ed wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Read less
Was this helpful?
Thank you for voting!
The old solenoid was slow to shut off causing the icemaker to overfill.
2 of 2 people
found this instruction helpful.
-
Cliff from ROCKVILLE, VA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Wrench set
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the bac
... Read more
k panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Read less
Was this helpful?
Thank you for voting!
refrigerator would not get cold
2 of 2 people
found this instruction helpful.
-
George from BERLIN, MD
- Very Easy
- 15 - 30 mins
-
Nutdriver
got on part select web site and found other customers that had same problem and on their site they had comments from them to fix problem. I then took off back panel on frig where compressor is by removing 6 screws and found the relay attached to the compressor then pressing down on holding spring removed 2 wire alligator clips and it was
... Read more
bad ordered one from part select put the new one on an frig was fixed. entire fix took about 30 minutes from isolating problem to fixing it. thank you part select
Read less
Was this helpful?
Thank you for voting!
Original evaporator fan (31 years old) was making a lot of worn bearing noise
2 of 2 people
found this instruction helpful.
-
T from SOUTHBURY, CT
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.
I did have to use the wire extensions ... Read more that were included as the replacement motor had the electric connections in a different location from the original motor.
Overall, this was an easy replacement.
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.
I did have to use the wire extensions ... Read more that were included as the replacement motor had the electric connections in a different location from the original motor.
Overall, this was an easy replacement.
Read less
Was this helpful?
Thank you for voting!
water not being drawn up into icemaker
3 of 5 people
found this instruction helpful.
-
timothy from aberdeen, MD
- Really Easy
- Less than 15 mins
-
Pliers
unplugged the old valve and disconnected the water line, then reconnected water line on new valve and plugged it in. It was an easy process but unfortunately that did not fix the problem. It is the ice maker it self so I will be ordering a replacement ice maker.
Was this helpful?
Thank you for voting!
light wouldn't come out of socket
3 of 5 people
found this instruction helpful.
-
Joyce from Tacoma, WA
- Really Easy
- Less than 15 mins
It just unpluged and the new one plugged in. Simple. The part was reasonable and arrived very quickly. It sure is nice to have a light in the frig again.
Was this helpful?
Thank you for voting!
Not cooling and freezer freezing up
6 of 14 people
found this instruction helpful.
-
kenneth from carmel, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
I removed the condenser cover removed old fan blade defrosted the condenser section installed new blade and reassembled
Was this helpful?
Thank you for voting!
light kept blinking on and off never same way
2 of 2 people
found this instruction helpful.
-
michael from CENTRALIA, IL
- Really Easy
- Less than 15 mins
-
Screw drivers
turn breaker off first then use thin blade screwdriver and plastic pry bar to remove light socket and switch there was plenty of wire so work was easy to install at both ends
Other Parts Used:
Was this helpful?
Thank you for voting!
Water leaking from bottom of refrigerator
2 of 2 people
found this instruction helpful.
-
Bill from ORO VALLEY, AZ
- Very Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
I'm not a DIY-er, and wasn't sure a 20 year old refrigerator was worth the repair, but for $30 I could afford to be wrong. The swap is pretty intuitive, especially in my case since the problem was that the water tube from the valve to the ice maker had detached from the coupling. So I didn't have to cut anything off, just inserted the
... Read more
tube into the new valve. Reconnected the supply line, screwed the assembly back on the refer, and Bob's your uncle. Other than unloading some canned goods to lighten the refer, longest process was finding the right size nut driver in my disorganized tool tray. Be aware, there are NO instructions included with the part. Found a good video on you tube that confirmed the obvious. Glad I took a shot!
Read less
Was this helpful?
Thank you for voting!
Refridgerator stopped making ice
2 of 2 people
found this instruction helpful.
-
Doug from COPE, CO
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
Was this helpful?
Thank you for voting!
a fan blade broken causing it to make a loud noise
3 of 5 people
found this instruction helpful.
-
Marnie from Denver, CO
- Really Easy
- Less than 15 mins
-
Pliers
we took off the old one and replaced it.
Was this helpful?
Thank you for voting!
ice maker was leaking
3 of 5 people
found this instruction helpful.
-
Phyllis from Minneapolis, MN
- Really Easy
- Less than 15 mins
-
Screw drivers
thats what I did is remove the teo screws and took the old single outlet valve out. And put the new one in and put the screws back in. First turned off the water and put the water back on after I was threw and no leaks.
Was this helpful?
Thank you for voting!
Broken drive cup in the ice dispencer
3 of 5 people
found this instruction helpful.
-
Robert from Bakersfield, CA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Emptied the ice from tray.
Removed the four screws that hold the face plate.
Removed the four screws that fasten drive housing to the tray.
Slid the drive cup into place at the end of the auger.
Made sure the rubber gasket was in place .
Replaced the four screw that hold the housing to the tray.
Replaced the ... Read more four screws that hold the face plate.
Put some ice cubes in the tray and tested to be sure everything worked properly.
Removed the four screws that hold the face plate.
Removed the four screws that fasten drive housing to the tray.
Slid the drive cup into place at the end of the auger.
Made sure the rubber gasket was in place .
Replaced the four screw that hold the housing to the tray.
Replaced the ... Read more four screws that hold the face plate.
Put some ice cubes in the tray and tested to be sure everything worked properly.
Read less
Was this helpful?
Thank you for voting!