de light flasing on freezer door electronic disply
12 of 12 people found this instruction helpful.
  • Sherri from Atlanta, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I removed the back wall panel inside the freezer compartment(approx. 6 screws). The coils were very iced up. I manually defrosted the the coils with a hand hair dryer. I then removed the 2 screws from each heater element and the clip-on thermostat from the coil. I pulled the elements, thermostat and wiring harness(item 230 on parts d iagram) out of the freezer compartment and installed the new assembly. Electronic self-check of the defroster indicated normal. Further checks indicated the lower heating element was open.
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people found this instruction helpful.
  • Terry from Simi Valley, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this helpful?
Thank you for voting!
Ice maker ot making ice
18 of 31 people found this instruction helpful.
  • Barry from Phoenix, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this helpful?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
12 of 13 people found this instruction helpful.
  • PERRY from VANDERBILT, MI
  • Easy
  • More than 2 hours
  • Nutdriver, Wrench set
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning whil e your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people found this instruction helpful.
  • Stephen from Jupiter, FL
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
ice would not dispense
14 of 19 people found this instruction helpful.
  • john from montgomery, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Socket set
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.
Was this helpful?
Thank you for voting!
The cam broke apart and the pieces were on the floor. The door did not close automatically. This was on the freezer side.
12 of 14 people found this instruction helpful.
  • Bennie from Gainesville, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I used the same steps as described in other descriptions listed here. Since I was changing the hinge assembly on the freezer side the difference I discovered was that there was a nylon water hose inside the hinge assembly that I did not at first know how to remove. I finally called a repairman I happened to know and following his instru ction simply snapped the hose loose where there was a connector and placed a cloth under it to catch the moisture that drained. Having done that, the rest of the assembly went just the same way as the other instructions listed here said that it would. Door now functions like new.
Was this helpful?
Thank you for voting!
Light switch broken/door handle worn
12 of 14 people found this instruction helpful.
  • Gene from Anaheim Hills, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
To repair the light switch you need to replace the control board since the switch is not replaceable. The control board is easily gotten to by removing the outer cover, which snaps out, the removing the screws that hold the housing for the control board, make sure you disconnect the power and turn off the water supply before you remove t he outer cover.. The board is held in place by a bracket which has two screws, make sure you disconnect the two wiring harnesses before the bracket. Once you get the bracket off the control board slides right out. To install the new board, just reverse the process.

Changing the handle is accomplished by remove popping out the top and bottom trim pieces, then remove the upper and lower screws from the handle. Reverse the process to install the handles.
Was this helpful?
Thank you for voting!
Ice Maker Timing was off
11 of 11 people found this instruction helpful.
  • Mark from Antelope, CA
  • Easy
  • Less than 15 mins
  • Screw drivers
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.
Was this helpful?
Thank you for voting!
Rust on parts
11 of 12 people found this instruction helpful.
  • Sally from Allen, TX
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I recommend taking a picture of any part before it is removed. Remove all screws. Use the diagram provided by this site for the dismantle of the ice bucket parts. I replaced the plate and ice auger. I found that my rusted screws for the plate would not fit the new plate, so I bought replacement screws at Home Depot. After I got all the blades off, I realized that I should have probably replaced a couple of them as well. Next time I decide to repair an item, I will totally inspect all parts before ordering. Order was shipped immediately. Postal Carrier showed me why he dropped off at another location which caused a delay of a couple of days. Not the senders problem. I had a hard time remembering just how the rod on the side was suppose to fit. I should have taken a picture. (laughing) I finally figured it out. My ice maker is as good as new. So happy I did this. My husband always says: " Just get a new refrigerator." I was raised to fix things until they just die. He was so impressed that I was able to follow the diagram and re-install the ice bucket. All is great. I will use this site again. They are a great company. I am sure I saved hundreds of dollars for a repairman who would have replaced the whole unit and not taken the time for the repair and replacement of parts. This was just "as easy as pie".
Was this helpful?
Thank you for voting!
Flapper was stuck open. Old and warped.
16 of 27 people found this instruction helpful.
  • James from Virginia Beach, VA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Replaced flapper
Was this helpful?
Thank you for voting!
Replace Dual Inlet Water Valve
16 of 27 people found this instruction helpful.
  • Timothy from West Windsor, NJ
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers, Wrench set
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.

New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
Was this helpful?
Thank you for voting!
This part on refrigerator went out, wouldn't dispense water.
13 of 18 people found this instruction helpful.
  • Glen from Harrisburg, OR
  • Really Easy
  • Less than 15 mins
  • Pliers
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.
Was this helpful?
Thank you for voting!
Fridge wouldn't start
12 of 15 people found this instruction helpful.
  • Patrick from Medford, NY
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Removed cowling unpluged timer and pluged in new one.
Great Service, got part in one day
Was this helpful?
Thank you for voting!
Light in the refrigerator went out
13 of 18 people found this instruction helpful.
  • Paulette B. from Santa Ana, CA
  • Really Easy
  • 15 - 30 mins
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.