Refrigerator to warm freezer ok
16 of 18 people
found this instruction helpful.
-
Christopher from Madison Heights, MI
- Easy
- Less than 15 mins
-
Nutdriver
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a whil
... Read more
e I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Read less
Was this helpful?
Thank you for voting!
Kickplate grille cracked
16 of 19 people
found this instruction helpful.
-
John from Georgtown, TX
- Really Easy
- Less than 15 mins
Pulled off cracked grille and inserted new in grille holders
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people
found this instruction helpful.
-
CHRIS from LAGUNA NIGUEL, CA
- Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds
... Read more
the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Read less
Was this helpful?
Thank you for voting!
Motor rattled loudly
15 of 17 people
found this instruction helpful.
-
Robert from Kingwood, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed
... Read more
3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Read less
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people
found this instruction helpful.
-
D from ZELLWOOD, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
My 13 yr grandson assisted me on this
15 of 18 people
found this instruction helpful.
-
Sherry from Auburn Hills, MI
- Really Easy
- Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
15 of 18 people
found this instruction helpful.
-
Lowell H from Gilbert, AZ
- Really Easy
- Less than 15 mins
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Was this helpful?
Thank you for voting!
Water Leak From The Ice Make - Water All Over The Frig
14 of 15 people
found this instruction helpful.
-
David T from Irvine, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to ident
... Read more
ify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Read less
Was this helpful?
Thank you for voting!
water line leaking behind refigerator
14 of 15 people
found this instruction helpful.
-
Michael from Merrimac, MA
- Easy
- 15 - 30 mins
-
Pliers
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everyt
... Read more
hing works fine with no leaks
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
The Dairy Door on my refrigerator came off and broke into pieces.
18 of 28 people
found this instruction helpful.
-
Catherine from Tampa, FL
- Really Easy
- Less than 15 mins
Using my refrigerator brand and model number, it took about a minute to find the replacement part number.Once I found it, I ordered the part. Within two days I received the part. Then all I had to do was snap the Dairy Door in place. No tools were required. PartSelect made the entire process very easy, and I would definitely use you agai
... Read more
n. Thanks!
Read less
Was this helpful?
Thank you for voting!
ice maker not making ice
16 of 22 people
found this instruction helpful.
-
Cristina from Los Angeles, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this helpful?
Thank you for voting!
Door hinge cam crumbled
14 of 16 people
found this instruction helpful.
-
Ralph from Portland, OR
- Really Easy
- 30 - 60 mins
-
Nutdriver
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.
Was this helpful?
Thank you for voting!
The ice maker door wouldn't open automatically
13 of 14 people
found this instruction helpful.
-
David from Albuquerque, NM
- Really Easy
- Less than 15 mins
-
Screw drivers
After replacing the solenoid several months ago, I concluded that the problem could only be the electronic circuit board that controls the timing and delay. The part arrived sooner than I expected. Installing it involved removing only six screws and unplugging two connections. The whole project took only about 10 minutes and now my ice ma
... Read more
ker works like new. Total cost was less than $55. Saved me several hundred dollars not to mention my personal time had I called in a repairman.
David O.
Albuquerque, NM
David O.
Albuquerque, NM
Read less
Was this helpful?
Thank you for voting!
The refrigerator was leaking water from the freezer section.
14 of 17 people
found this instruction helpful.
-
Joe from Summerton, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.
Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.
After the pane ... Read more l is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.
Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.
Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.
Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.
Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.
Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!
P.S. Don't forget to put the food back in the freezer.
Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.
After the pane ... Read more l is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.
Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.
Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.
Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.
Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.
Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!
P.S. Don't forget to put the food back in the freezer.
Read less
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people
found this instruction helpful.
-
Terry from Simi Valley, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s
... Read more
o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Read less
Was this helpful?
Thank you for voting!