- Home
- TPX21PRSAWW
- Instructions
TPX21PRSAWW General Electric Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
broken bucket and drive cup
9 of 10 people
found this instruction helpful.
-
David from Lawrenceville, GA
- Really Easy
- 15 - 30 mins
-
Screw drivers
turned the ice maker off then removed the ice bucket and place the ice into a bucket then removed the 6 screws that hold the front plate to the bucket. then replace the bucket and front panel. Replaced the ice cubes into the bucket and test the agruer that ice dispenser and turnred ice maker back on
Other Parts Used:
Was this helpful?
Thank you for voting!
Door slams open
9 of 10 people
found this instruction helpful.
-
Anthony from Southbridge, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Changed the door stop and hinge assembly. Door works perfectly.
Other Parts Used:
Was this helpful?
Thank you for voting!
Burnt out heater defront unit
8 of 8 people
found this instruction helpful.
-
Fred from Martinez, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
1. Turned unit off and removed freezer shelving
2. Removed 5 screws on back pannel to expose heaters
3. Deforsted coils with a hair dryer and removed ice cubes
4. Compaired new defrost harness to the existing
5. Removed 4 screws holding the defective harness
6. Installed new heater harness with 4 screws and elec. ... Read more plug
7. Reinstalled back pannel and shelving
8. Turned unit back on
2. Removed 5 screws on back pannel to expose heaters
3. Deforsted coils with a hair dryer and removed ice cubes
4. Compaired new defrost harness to the existing
5. Removed 4 screws holding the defective harness
6. Installed new heater harness with 4 screws and elec. ... Read more plug
7. Reinstalled back pannel and shelving
8. Turned unit back on
Read less
Was this helpful?
Thank you for voting!
refrigerator did not cool
10 of 14 people
found this instruction helpful.
-
Carl from Kent City, MI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
i put a new evaporator motor in and now it works fine
Was this helpful?
Thank you for voting!
Faded door handles
8 of 8 people
found this instruction helpful.
-
Errol from Locust Grove, GA
- Really Easy
- Less than 15 mins
-
Screw drivers
Simply lifted up the molding with a flat head screw driver, removed the screws then removed the old handles and replaced with the new ones. Pressed the molding back into place. Easy a pie. Great Service too.
Was this helpful?
Thank you for voting!
Will not make ice
13 of 23 people
found this instruction helpful.
-
GEORGE from ELIOT, ME
- Easy
- Less than 15 mins
-
Screw drivers
Bing , Bang, Boom.
Was this helpful?
Thank you for voting!
Ice Maker was leaking all over freezer compartment
9 of 11 people
found this instruction helpful.
-
Mary from Langhorne, PA
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench set
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try t
... Read more
o stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.
Read less
Was this helpful?
Thank you for voting!
Would not despense ice and getting matal and plastic shavings in Ice when it did despense.
10 of 14 people
found this instruction helpful.
-
Louie from Lake Park, GA
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Removed screws that held crusher to metal plate, making note of how unit came apart. Replaced Ice bucket auger and front and rear helix. I had to also order bushing/nut that screws to end of auger as the threads on mine were stripped out . I used the parts view on PartSelect.com to help in reassembly of the ice crusher blades, without tha
... Read more
t view it would have been trial and error in their proper assembly as I had forgotten ( because from 1st parts reciept and second parts reciept being about a week) how they came out. After assembly, with no left over parts I might add, I installed unit in to freezer and it works like new.
Thanks, Louie D.
Thanks, Louie D.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
9 of 12 people
found this instruction helpful.
-
Tim from The Woodlands, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the o
... Read more
ld part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Read less
Was this helpful?
Thank you for voting!
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
10 of 15 people
found this instruction helpful.
-
Drew from Spring Lake, NJ
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench set
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Par
... Read more
tselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Read less
Was this helpful?
Thank you for voting!
Fan had quit; needed replacement.
10 of 15 people
found this instruction helpful.
-
John from Divide, CO
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & deliver
... Read more
y were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
John Moragues
Read less
Was this helpful?
Thank you for voting!
Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix
9 of 12 people
found this instruction helpful.
-
Osvaldo from Miami, FL
- Easy
- 30 - 60 mins
-
Screw drivers, Wrench (Adjustable)
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there i
... Read more
s no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
would not defrost
7 of 7 people
found this instruction helpful.
-
Richard from Quakertown, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coil
... Read more
s but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
Read less
Was this helpful?
Thank you for voting!
freezer coil iceing up
7 of 7 people
found this instruction helpful.
-
Paul from Palmdale, CA
- Easy
- 30 - 60 mins
-
Screw drivers
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
Was this helpful?
Thank you for voting!
freezer not frezing properly frost buildup
7 of 7 people
found this instruction helpful.
-
Bill from Columbiana, AL
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Was this helpful?
Thank you for voting!