Cracked housing on the vaave
288 of 308 people
found this instruction helpful.
-
anthony from thornton, CO
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench (Adjustable)
1. Turn off water supply, and electrical ( unplug it) to fridge.
2. Remove water line to valve. Watch for water to pour out of the line. Have a towel handy.
3. Remove the cardboard cover on the bottom of the fridge.
4. Remove the screws that hold the valve in place.
5. Remove the valve, be careful the waterlines ar ... Read more e still attached.
6. Place a towel under valve to catch any water that leaks out from water lines.
7. Remove electrical lines, make sure to mark which went where. One is for the ice, and one is for the water. Make sure the power is off, there is 120 volts present at those connections.
- now my waterlines attached using a compression type fitting. The new valve I got used just a push in type of attachment. But, easy enough I just removed the pieces for the compression and the waterlines pushed right in and worked fine.
- the mounting harness for the valve was alittle different but the parts I need were in the right location and she fit in fine.
8. Attach water lines. They are different sizes so you can't get those mixed up.
9. Attach electrical lines.
- the new valve came with adaptors for my electrical connection. Just snapped them on and kept on going.
10. turn on watersupply for fridge. Plug it back in.
11. Test for leaks, and proper operation. ie. When you push the water does the water valve open?
12. Unplug fridge
13. Now is a good time to clean out any dust or dirt that has accumallated in under around your fridge.
14. reassemble, valve, then cover. move fridge back into place.
15. Plug fridge back in.
16. Take a clean glass.
17. Fill with water from the front.
18. Take full glass of water and go watch tv. You've earned it, and saved yourself probably $100.00 in labor costs. Good Job.
2. Remove water line to valve. Watch for water to pour out of the line. Have a towel handy.
3. Remove the cardboard cover on the bottom of the fridge.
4. Remove the screws that hold the valve in place.
5. Remove the valve, be careful the waterlines ar ... Read more e still attached.
6. Place a towel under valve to catch any water that leaks out from water lines.
7. Remove electrical lines, make sure to mark which went where. One is for the ice, and one is for the water. Make sure the power is off, there is 120 volts present at those connections.
- now my waterlines attached using a compression type fitting. The new valve I got used just a push in type of attachment. But, easy enough I just removed the pieces for the compression and the waterlines pushed right in and worked fine.
- the mounting harness for the valve was alittle different but the parts I need were in the right location and she fit in fine.
8. Attach water lines. They are different sizes so you can't get those mixed up.
9. Attach electrical lines.
- the new valve came with adaptors for my electrical connection. Just snapped them on and kept on going.
10. turn on watersupply for fridge. Plug it back in.
11. Test for leaks, and proper operation. ie. When you push the water does the water valve open?
12. Unplug fridge
13. Now is a good time to clean out any dust or dirt that has accumallated in under around your fridge.
14. reassemble, valve, then cover. move fridge back into place.
15. Plug fridge back in.
16. Take a clean glass.
17. Fill with water from the front.
18. Take full glass of water and go watch tv. You've earned it, and saved yourself probably $100.00 in labor costs. Good Job.
Read less
Was this helpful?
Thank you for voting!
Panel hot to touch between freezer & refrigerator. Motor hot, fan not rotating.
32 of 39 people
found this instruction helpful.
-
Kimberly from Grandy, NC
- Really Easy
- 15 - 30 mins
-
Screw drivers
Unplugged refrigerator, removed three screws to take out part, disconnected the wires and removed bad unit. Removed fan blade from old unit and attached to the new unit. Attached wires, placed the new motor back in. Plugged it back in, within 20 minutes panel between freezer and refrigerator was cool to touch.
Was this helpful?
Thank you for voting!
during defrost cycle water dripped into freezer and froze all over ice bin
27 of 29 people
found this instruction helpful.
-
Bob from Aurora, IL
- Easy
- 1- 2 hours
-
Screw drivers
First I removed the ice maker. Second I removed the back panel and overhead panel above ice maker. Third I pulled down the drip trough it had a styrofoam base under it. The trough heater had to be unplugged to remove the trough as well as the drain hose. Forth I seperated the styrofoam from the trough and peeled off the old heater whi
... Read more
ch had burn marks on the foil. Fifth I applied the new heater plugged it in and attached the drain hose to the trough. Last I reassembled the unit. Refridgerator works great now and it only cost $45.00 for the heater. The GE repair service quoted over $950.00 and did not list the trough heater as the problem so I would be spending more and would have required several repair visits.
Read less
Was this helpful?
Thank you for voting!
low flowing water (not just a drip) from refrigerator ice maker
23 of 30 people
found this instruction helpful.
-
Theresa from Rochester, MI
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers, Wrench (Adjustable)
The icemaker's valve is easy to inspect and test. First, gently pull the refrigerator away from the wall, and unplug it. Turn off the water supply to the icemaker by closing the shut-off valve in the copper waterline leading to the valve. Use a screwdriver or nutdriver to remove the rear lower access panel from the refrigerator's back.
... Read more
r />
Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.
Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.
Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.
Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.
Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.
Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.
Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.
Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.
Read less
Was this helpful?
Thank you for voting!
This refrigerator had pawer( lite was on) but nothing turning--motor or fan. Turned control temperature min-max - no cange.
49 of 112 people
found this instruction helpful.
-
HAE-YOUNG from Douglaston, NY
- Easy
- 1- 2 hours
-
Screw drivers
Found burned Defrost timer contacts.
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people
found this instruction helpful.
-
CHRIS from LAGUNA NIGUEL, CA
- Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds
... Read more
the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Read less
Was this helpful?
Thank you for voting!
Motor rattled loudly
15 of 17 people
found this instruction helpful.
-
Robert from Kingwood, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed
... Read more
3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Read less
Was this helpful?
Thank you for voting!
Water Leak From The Ice Make - Water All Over The Frig
14 of 15 people
found this instruction helpful.
-
David T from Irvine, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to ident
... Read more
ify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Read less
Was this helpful?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
12 of 13 people
found this instruction helpful.
-
PERRY from VANDERBILT, MI
- Easy
- More than 2 hours
-
Nutdriver, Wrench set
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning whil
... Read more
e your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Read less
Was this helpful?
Thank you for voting!
Replace Dual Inlet Water Valve
16 of 27 people
found this instruction helpful.
-
Timothy from West Windsor, NJ
- Easy
- Less than 15 mins
-
Pliers, Screw drivers, Wrench set
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.
New valve - remove plastic shipping protection guard, remove rubber cap from supply ... Read more connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
New valve - remove plastic shipping protection guard, remove rubber cap from supply ... Read more connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
Read less
Was this helpful?
Thank you for voting!
This part on refrigerator went out, wouldn't dispense water.
13 of 18 people
found this instruction helpful.
-
Glen from Harrisburg, OR
- Really Easy
- Less than 15 mins
-
Pliers
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.
Was this helpful?
Thank you for voting!
water valve leak
10 of 10 people
found this instruction helpful.
-
Scott from Columbus, IN
- Easy
- Less than 15 mins
-
Pliers, Screw drivers, Wrench set
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure
... Read more
It Is Right Because You Only Get One Shot At It.
Read less
Was this helpful?
Thank you for voting!
fridge quit coolingg / freezing
11 of 13 people
found this instruction helpful.
-
JEFF from HAMPTON, GA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - rep
... Read more
laced cover - was hero with wife ... :-)
Read less
Was this helpful?
Thank you for voting!
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
10 of 11 people
found this instruction helpful.
-
Kirk E from GRASS VALLEY, CA
- Easy
- Less than 15 mins
-
Screw drivers
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I search ... Read more ed and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I search ... Read more ed and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Read less
Was this helpful?
Thank you for voting!
Refrigerator not defrosting.
11 of 15 people
found this instruction helpful.
-
Michael from Tappan, NY
- Difficult
- More than 2 hours
-
Screw drivers
After gaining access thto the Evaporator Coil, lots of disassembly, I was able to cut the foam (Heater Trough) and remove it first (in pieces). This allowed room to lower the Condensate pan and slide it out to replace the Heating Coil, which was also purchased from you. Don't forget to disconnect the drain hose. Because of the "V" shape o
... Read more
f the pan, the rear portion of the foam trough had to be removed to allow reassembly. I still have to verify whether the Defrost Timer is working properly, but the unit is coolingto proper temperatures (Freezer and Refrigerator).
Regards,
Mike Hall
Regards,
Mike Hall