Would not cool top or bottom
5 of 6 people
found this instruction helpful.
-
David from White Pine, TN
- Really Easy
- 15 - 30 mins
-
Nutdriver
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Was this helpful?
Thank you for voting!
broken auger in the bucket assembly.
6 of 9 people
found this instruction helpful.
-
Chip from Mandeville, LA
- Easy
- Less than 15 mins
-
Nutdriver
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this helpful?
Thank you for voting!
evap fan not working.
6 of 9 people
found this instruction helpful.
-
louis from floral park, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15
... Read more
minutes time ... thank you for your product it really did the job..
Read less
Was this helpful?
Thank you for voting!
Ice maker water valve failed open.
5 of 7 people
found this instruction helpful.
-
O. V. from Virginia Beach, VA
- Easy
- 1- 2 hours
-
Nutdriver, Screw drivers, Socket set, Wrench set
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle prompt
... Read more
ly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Read less
Was this helpful?
Thank you for voting!
broken dairy door cover
5 of 7 people
found this instruction helpful.
-
Tom from Fresno, CA
- Really Easy
- Less than 15 mins
removed old one and installed new one. 30 seconds.
Was this helpful?
Thank you for voting!
Icemaker solenoid housing cracked
5 of 7 people
found this instruction helpful.
-
Mark from Bayside, NY
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solen ... Read more oid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
I plugged in the solen ... Read more oid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
Read less
Was this helpful?
Thank you for voting!
Wasn't Getting Any Water To The Icemaker
5 of 7 people
found this instruction helpful.
-
Mark from Ft. Lauderdale, FL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new wat
... Read more
er valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
Read less
Was this helpful?
Thank you for voting!
The Icemaker failed to make ice
8 of 16 people
found this instruction helpful.
-
Dean from Folsom, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement i
... Read more
cemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Read less
Was this helpful?
Thank you for voting!
The Ground wires wasn't in same location on board
4 of 4 people
found this instruction helpful.
-
Johnnie from KANSAS CITY, MO
- Easy
- 30 - 60 mins
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
Was this helpful?
Thank you for voting!
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
5 of 7 people
found this instruction helpful.
-
Rickey from DUMAS, AR
- Really Easy
- 30 - 60 mins
-
Socket set
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugge
... Read more
d it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Read less
Was this helpful?
Thank you for voting!
Electric surge from lightening strike close to house
4 of 5 people
found this instruction helpful.
-
Richard from Clarksville, GA
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and
... Read more
has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice cream melting, lettuce freezing
4 of 5 people
found this instruction helpful.
-
Tim from Mountain View, AR
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
Was this helpful?
Thank you for voting!
no ice made
5 of 8 people
found this instruction helpful.
-
Robert from San Marcos, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of s
... Read more
crews had ice again !
Read less
Was this helpful?
Thank you for voting!
Freezer/Fridge not cold & compresser would not turn on.
4 of 5 people
found this instruction helpful.
-
Linda from Tiverton, RI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. Aft
... Read more
er narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
Read less
Was this helpful?
Thank you for voting!
cracked valve
6 of 11 people
found this instruction helpful.
-
Don from Crete, IL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Was this helpful?