Erratic light.
9 of 11 people
found this instruction helpful.
-
D KIRKE from CORVALLIS, OR
- Really Easy
- Less than 15 mins
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement s
... Read more
witch.
Read less
Was this helpful?
Thank you for voting!
Freezer Door Leaking
8 of 8 people
found this instruction helpful.
-
Danielle from LAKEWOOD, CO
- Very Easy
- Less than 15 mins
My issue was water leaking from the door. I thought it was the gasket, so I removed the gasket and the entire panel off of the door. There was water behind it that had soaked the cardboard seal, so I left that front part off for over a week to let it dry. We determined between us and our two toddlers that perhaps the door hadn't been prop
... Read more
erly closed enough on a number of occasions, so before I bought a $100 gasket, I'd try making sure the door was shut with tape, turning the freezer on and seeing what happened. There was no water after a few days, so on another user's suggestion I purchased the $15 key and twist tied it to the freezer door. Now I am locking the door after use so we won't have leaking water any longer.
Read less
Was this helpful?
Thank you for voting!
Freezer not defrosting
8 of 9 people
found this instruction helpful.
-
Tom from Argyle, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside
... Read more
freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Read less
Was this helpful?
Thank you for voting!
The door handle broke off of the freezer.
9 of 13 people
found this instruction helpful.
-
Stephanie from Irving, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
The repair was really easy - I used a phillips head screw driver to remove the screws and broken pieces of the handle, screwed the new one on and snapped the handle insert into place. I was thrilled to be able to find the parts so easily (the information you have online is really helpful!), the parts arrived much faster than I anticipated
... Read more
and the handle was easily replaced! Thank you!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people
found this instruction helpful.
-
Gregg from Mohnton, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?
Thank you for voting!
Coils freezing up and refrigerator would get warm
6 of 7 people
found this instruction helpful.
-
Richard from Scranton, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Read less
Was this helpful?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
5 of 5 people
found this instruction helpful.
-
Arthur from Lithonia, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested
... Read more
good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Read less
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people
found this instruction helpful.
-
Jeanne from SAN ANTONIO, TX
- Very Easy
- Less than 15 mins
-
Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people
found this instruction helpful.
-
Marsha from BEVERLY, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely
... Read more
does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Read less
Was this helpful?
Thank you for voting!
refrigerator stopped cooling
11 of 23 people
found this instruction helpful.
-
Lisa from Los Angeles, CA
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
After the refrigerator stopped cooling, we determined that the problem was in the compressor area. we used a screwdriver to get the cover off and then vice grips to get the actual pieces out (start relay & overload)--they broke, but they were already broken). We went to the Home Depot site to purchase the parts, but found PartSelect to b
... Read more
e much less expensive. Put the parts in when they came a few days later and it worked! thank you PartSelect!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer would not defrost
5 of 6 people
found this instruction helpful.
-
Fernando from La Grange, AL
- Easy
- 30 - 60 mins
-
Screw drivers, Wrench set
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
Was this helpful?
Thank you for voting!
I Lost The Key
5 of 7 people
found this instruction helpful.
-
VICKIE from DAWSON, GA
- Really Easy
- 15 - 30 mins
I order another one thanks
Was this helpful?
Thank you for voting!
Freezer would not run ... replace the compressor start relay which fixed the problem
4 of 4 people
found this instruction helpful.
-
Tom from CEDARTOWN, GA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Pulled out the freezer. Unplugged. No freezer back cover was there. The compressor start relay was in a plastic encasement attached to the compressor - wires led me to it. Removed the solid metal spring with a screwdriver and removed the plastic cover. Tried to pull out the defective relay but the freezer was so old I needed a pliers to r
... Read more
emove it. When I put pressure on the old relay with the pliers the relay broke and came off in pieces. I then removed the wires from the broken parts and put them on the new relay. I pushed the new relay onto the 2 pins then replaced the cover and spring. After plugging the freezer in the problem was fixed.
Read less
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people
found this instruction helpful.
-
DAVE from LOS RANCHOS, NM
- Very Easy
- Less than 15 mins
-
Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th
... Read more
e video that was on-line helpful also.
Read less
Was this helpful?
Thank you for voting!
Freezer coils kept freezing over.
4 of 6 people
found this instruction helpful.
-
Kyle from Porter, OK
- Really Easy
- Less than 15 mins
-
Nutdriver
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed th ... Read more e Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed th ... Read more e Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Read less
Was this helpful?
Thank you for voting!