Water Leak in vegetable Drawers
13 of 17 people found this instruction helpful.
  • John from Miami, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
shut off water supply to unit, pull the unit out,unplug, unscrew lower back cover, locate valve relay unit (bottom left, black and clear hose coming out of it) undo the quick connect for the clear water hose on the right (black one is for ice).

front of the unit, bottom left, locate the other hose (longer one) running to the f reezer door from under the unit, undo quick connect.

Inside unit, remove middle drawers, careful with the glass panels as these just lay on top and are not fixed.

undo the 3 screws for the old tank, pull it out, snake the hoses thru the grommet on the bottom, reverse process...all set!
Was this helpful?
Thank you for voting!
Freezer thawing then re-freezing
12 of 15 people found this instruction helpful.
  • Luther from Navarre, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers
The refrigerator was staying in defrost too long allowing the temperature to rise to the point that part of the ice (probably some of the food too) to melt then re-freeze. I first changed out the temp sensor and thermostat because I wanted to try the cheap stuff first but that didn't fix it, I should have gone with the mainboard first as it was the most likely cause. After putting in the new mainboard in the thing has worked perfectly since. The board was extremely easy to change, take the metal cover off with a nut driver. Carefully unplug the wires from old board and remove the board. The board is mounted on some plastic standoffs that expand after passing through the board, some of these came out while i was disconnecting the wires but some were there to stay until I figured out that I needed to squeeze the top of them to release the board. After getting the old board out just put the new one on the standoffs and connect the wires. Put the cover back on and DONE!

NOTES: The new board had some extra connectors that my old one did not, but the correct connectors were still in the old locations. The instructions that came with the board did talk about making some modifications to the refrigerator wiring on certain models, but that didn't apply to me. If I remember right the models requiring modification were all bottom freezer type. But even if you do have to do this the instrucions looked easy, just cut a couple of wires, no splicing or anything.
Was this helpful?
Thank you for voting!
Light in the refrigerator went out
13 of 18 people found this instruction helpful.
  • Paulette B. from Santa Ana, CA
  • Really Easy
  • 15 - 30 mins
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.

Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.

Paulette Johnson
Was this helpful?
Thank you for voting!
Burned out motor for dispensing ice
14 of 21 people found this instruction helpful.
  • Peter from Lake Grove, NY
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Remove ice holding box. Remove rear plastic cover (nut driver) Unplug two Electrical connectors. Place unit on work bench. Remove 'U' fork, vice grip on shaft and scewdiver as lever on fork (counter clockwise) Remove motor fron plastic Holder. Install new motor & fork. Reverse removal steps. Actually very simple procedure. Usual c ost for this typwe of repair is approx. $300.00.
Was this helpful?
Thank you for voting!
slow water flow in dispenser
14 of 21 people found this instruction helpful.
  • dwight from phoenix, AZ
  • Really Easy
  • Less than 15 mins
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this helpful?
Thank you for voting!
Ice Cube Dispencer Would Not Turn
12 of 15 people found this instruction helpful.
  • EUGENE from BURLEY, ID
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Dispencer quit working a year ago, but still still dispenced water. I talked to a service technician about it. He told me the electric motor was froze up, so I orderd a new one. When it arrived I installed it in about 20 minnutes,tried the dispencer and still would not work but this time the water would not dispence eather and this time I noticed the fan quit running and the light went dim when I tried to dispence ice. So I read the customers diagnosis and repares every thing pointed to the main control board, orderd the part and water filter. When they arrived in three days I watched installing this part video and it took me 20 minnutes to install and every thing works fine.
Was this helpful?
Thank you for voting!
filter replacement/water tray replace
12 of 16 people found this instruction helpful.
  • ron from Winter Haven, FL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
remove by hand turning old and replacing new by turning by hand.Lifted out old grill and placed in new one
Was this helpful?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
16 of 28 people found this instruction helpful.
  • Laura from Manchester, NH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this helpful?
Thank you for voting!
Motherboard burned out
11 of 13 people found this instruction helpful.
  • Joe from Redlands, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I ordered the part on Sunday and had it by Tuesday. It only took a few minutes to install. Basically, I unplugged the unit and removed the cover over the motherboard with a nutdriver. The wires were easy to unplug and reinstall. There was no way to incorrectly install since they could only fit in the correct position. I reinstalled t he panel pluged it back in and now the fridge is working great.
Was this helpful?
Thank you for voting!
Refridgerator Freezer stoped making ice
17 of 31 people found this instruction helpful.
  • Marion from Palm Coast, FL
  • Easy
  • 30 - 60 mins
  • Screw drivers
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Si licone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this helpful?
Thank you for voting!
Ice machine wasnt making ice
14 of 23 people found this instruction helpful.
  • Robert from Auburn, AL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection bac k in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this helpful?
Thank you for voting!
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
10 of 11 people found this instruction helpful.
  • Kirk E from GRASS VALLEY, CA
  • Easy
  • Less than 15 mins
  • Screw drivers
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I search ed and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.

Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Was this helpful?
Thank you for voting!
defrost heater burned out. Lots of ice in and ont he evaporator. Both breezer and refrigerator do not cool right.
10 of 11 people found this instruction helpful.
  • xiaopeng from canton, MI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Disconnected power. Removed evaporator cover in freezer. Removed the bad defrost heater. It is a glass tube about 10" long. The tube was black since the internal heater wire burned out. Use a hair dryer to melt ice in evaporator. Since there was excessive water coming from melt ice, I removed the back panel and took out the white plastic drain tube and collected water from the tube in a bucket. I put everything back and used the refrigerator for three days without problem, before the new heater arrived. Then I put on the new tube and everything was fine so far.
Was this helpful?
Thank you for voting!
It started out with the door buttons not working and then the timer stopped working so it wouldn't allow the fan or the compressor to run replaced the board and everything started working
11 of 15 people found this instruction helpful.
  • Robert from Yulee, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Took the three screws out of the cover, took the six plugs off of the board and removed board.
Was this helpful?
Thank you for voting!
Ice maker Stripper lost a tooth
10 of 12 people found this instruction helpful.
  • Ernest W. from Charlotte, NC
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the n ew stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this helpful?