Ice would not dispense
10 of 17 people
found this instruction helpful.
-
Henry from Larose, LA
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
By reading another customers tip I decided that my problem was the exact same. I had to order the entire motor not just the auger because the motor shaft was stripped. Once you remove the motor, hold the shaft with a pair of vise grips and use a screw driver to turn the auger off clockwise. The threads are reversed. The new auger screw
... Read more
s easily onto the new motor counterclockwise and installing back into the fridge was a snap.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
dispensed water but not cubes/crushed ice.
7 of 8 people
found this instruction helpful.
-
Tim from Klamath Falls, OR
- Easy
- 15 - 30 mins
-
Nutdriver
removed 3 screws with 1/4 " nut driver, unplugged 2 plugs by prying out on side tabs, removed bracket and motor. Used vice grips to hold motor shaft and used screwdriver to turn auger fork clockwise and remove. Unplugged two connectors from motor. removed 3 screws with 1/4" nut driver to remove motor. changed rubber boot from old motor to
... Read more
new. Reversed procedures to install new motor on bracket, auger fork, bracket in freezer, etc. Only difficulty getting both hands in narrow freezer compartment. Still didn't work, called repairman. When he got here I showed him the problem and lo and behold, now it would not dispense water. He diagnosed it as a bad motherboard, replaced it and all good now. Motherboard $150, diagnose and labor $90, but it is all good now and I even have a spare motor. The failing mother board causes strange howling noises at times and we discovered the compressor fan had also stopped working and in a short while I would have had a bad problem. Caught it just in time!!!
Read less
Was this helpful?
Thank you for voting!
GE Profile Arctica food locker was below freezing
7 of 9 people
found this instruction helpful.
-
Frederick K from Kingston, TN
- Easy
- 30 - 60 mins
-
Screw drivers
The trouble shooting information on the web site indicated that the damper door within the climate control unit may be broken. This was easily confirmed and the replacement of the climate control unit immediately returned the food locker temperatures to the digital electronic thermostat settings. The part has an improved ventilation gaske
... Read more
t interface between the food locker and freezer. The unit works perfectly again, and the food locker temperature is exactly what the thermostat setting is.
Read less
Was this helpful?
Thank you for voting!
Low water flow from indoor water dispenser
7 of 9 people
found this instruction helpful.
-
Ricky from Virginia Beach, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Disconnect main water line from behind refrigerator
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator rem ... Read more ove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator rem ... Read more ove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
Read less
Was this helpful?
Thank you for voting!
Stripped Front Leveling Roller & Screw
6 of 6 people
found this instruction helpful.
-
George from ARLINGTON, VA
- Easy
- 30 - 60 mins
-
Socket set
Raised side of fridge enough to get 1/4" ratchet with 1/4" socket under roller wheel assy. Removed three hex-head screws to separate damaged wheel assy from fridge frame. From panel below fridge compartment, backed-out stripped leveling screw. Mounted new roller assy and then threaded in new leveling screw from front. Lowered fridge a
... Read more
nd adjusted leveling screw for proper height. Suggest putting a 2x4 under fridge for safety when hands are under unit.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Old tray had split hands.
6 of 6 people
found this instruction helpful.
-
Mark from LAKE WORTH, FL
- Very Easy
- Less than 15 mins
Slip out old one, slide in new tray!
Was this helpful?
Thank you for voting!
Refrigerator door switch went bad
8 of 12 people
found this instruction helpful.
-
Jeffrey from lake Stevens, WA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
It was very simple! I assessed the situation and gathered my tools for the job. I used a flat head screwdriver, pliers, and electrical tape. I used the flat head screwdriver to release the switch from its location, the pliers to take the electrical terminations apart. I taped the wires individual so that I would not loose them in the door
... Read more
, also not to short them out. I then unpackaged the new switch to install. Pulled the tape off one of the of the terminals while holding the wire, and attached it to the new switchs terminal post. Did the same with the other wire, then snapped the new switch back into place. Immediately had results. I opened and closed the door a few times in amazement that something so annoying such as a light in your fridge could be so easy to fix. Most of all, having a business to rely on to find the part and deliver in a timely fashion. Thank you Partselect.com, you were outstanding!!!
Read less
Was this helpful?
Thank you for voting!
Light switch shorting out causing open door alarm to go off
7 of 9 people
found this instruction helpful.
-
George from Mount Prospect, IL
- Really Easy
- Less than 15 mins
-
Screw drivers
Easy fix, but they don't give you plenty of wire to work with. When I pulled the switch out it only had about an inch of wire that came with it. meaning if I didn't have a grasp on the wires as I was removing the switch they would have slipped back up the opening
Was this helpful?
Thank you for voting!
Water in door dispensor quit working
7 of 9 people
found this instruction helpful.
-
Richard from Temecula, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
First, I turned off the water supply line to the refrigerator from the house at the wall and unplugged the power cord. Secondly, I removed the small screws that hold the piece of cardboard over the opening in the lower left corner (rear of the refrigerator) by the compressor. Thirdlyl, I removed the other end of the water line where
... Read more
it attaches to the water valve with an adjustable end wrench. Then I removed the small screw that holds the double water outlet valves to the refrigerator frame. I then removed the water valve by pulling it out of the rear of the refrigerator, unplugged the electrical connections, and cut the water lines where they enter the valves. I then plugged the electrical connectors into the new valves and pushed the hoses into their respective openings. These are one-way connectors - once you push them in (firmly) they will not leak or come back out. All I did then was replace the valve and secure it with the one little screw and then replace the cardboard piece onto the rear of the refrigerator. Don't forget to turn the water supply back on. That's it!!
Read less
Was this helpful?
Thank you for voting!
refrigerator and freezer would not cool down.
6 of 6 people
found this instruction helpful.
-
John from Lakeland, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
First, we called Sears Repair and had a technician come to our home. He stated the motherboard had gone bad probably due to a power surge (we had no surge protector on the appliance). His price for repair was $465.00. We opted to go online for the part and found it for $165.00 through PartSelect.com. It was a very simple procedure of remo
... Read more
ving the old and installing the new. A few turns with the nut driver to uncover the part, a few tugs with the pliers to disconnect and voila!.. The fridge was back to cooling in no time.
Read less
Was this helpful?
Thank you for voting!
water dispenser was slowly leaking
6 of 7 people
found this instruction helpful.
-
Robert from Huber Heights, OH
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers
Shut off water supply. Unplugged refrigerator. Removed cover. (6 screws -- nutdriver will come in handy). Removed screw securing water valve to frame (again the nutdriver). Unplugged red and white power connectors to solenoids. Using channel locks, loosened nut holding main water supply to valve and removed. Depressed compression f
... Read more
ittings to valve and pulled out plastic water lines that supply water dispenser and ice maker. Reconnected main water supply to new part. Pushed both water lines into respective fittings of new part. Reconnected power supply to solenoids. Attached new part to frame with screw. Replaced back cover. Turned water supply back on. Plugged refrig. back in. Problem solved! Savings = $300!
Read less
Was this helpful?
Thank you for voting!
water leak on floor
6 of 7 people
found this instruction helpful.
-
Gerald from Colorado Springs, CO
- Easy
- 30 - 60 mins
-
Nutdriver, Socket set, Wrench set
pulled out refer. found leak at corner lower back, pulled off lower cover. found valve for icemaker leaking. looked in owners/inst guide, pulled up on computer, identified part, called, order overnight part. recieved part & installed, repair complete & successful.
Was this helpful?
Thank you for voting!
Coils in Freezer over frosted restricting air flow.Warm Frig.
7 of 10 people
found this instruction helpful.
-
Timothy from Hartford, MI
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
1) Unplug Refrigerator. Remove all shelves and light shield in the freezer.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the w ... Read more ire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the w ... Read more ire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
Read less
Was this helpful?
Thank you for voting!
No water out of refrigerator but had ice
6 of 7 people
found this instruction helpful.
-
G Michael from MONROE, OH
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
Followed the video showing how it was done. Took me longer to go to the basement and shut the water off and on, than it did to replace the valve
Was this helpful?
Thank you for voting!
Water will not dispense and the refrigerator drawers were freezing our foods and vegetables.
5 of 5 people
found this instruction helpful.
-
Jeff from Manteca, CA
- Easy
- 30 - 60 mins
-
Screw drivers
It was a simple remove and replace. The new part fits directly in place of the old part. Its a pain to remove the light but once you get the light out the job is simple. The light must be pried out gently. It is snapped in place toward the air inlet cover and needs to be pried loose. Once the light is out there are 4 screws holding
... Read more
the air inlet cover in place. Remove the 4 screws and unfasten the wiring harness. Once the screws and wiring harness are disconnected remove the old part. Reinstall the new part in reverse order.
Read less
Was this helpful?
Thank you for voting!