Received the Temp Sensor but no documentation how to replace it
28 of 41 people
found this instruction helpful.
-
Stephen from Sebring, FL
- Very Difficult
- More than 2 hours
I still have not be able to replace the sensor as I've been unable to locate any info, or figure out where it is located. The water valve was easy to replace and took less than a half hour
After looking further into your website I found all the info, diagrams and instructions to replace the Temp Sensor, which was not too involv ... Read more ed, thank you. Now to wait and see if this was the cause and my Refrigerator is up and running again
After looking further into your website I found all the info, diagrams and instructions to replace the Temp Sensor, which was not too involv ... Read more ed, thank you. Now to wait and see if this was the cause and my Refrigerator is up and running again
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Water leaked constantly from water dispenser in door
22 of 24 people
found this instruction helpful.
-
John from Dexter, MO
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.
Was this helpful?
Thank you for voting!
I had a water leak (undiscovered) from under my refrig
22 of 24 people
found this instruction helpful.
-
Daniel from Anderson, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the
... Read more
replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
Read less
Was this helpful?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
24 of 30 people
found this instruction helpful.
-
John from Windham, NH
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers, Socket set
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged r
... Read more
efridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Read less
Was this helpful?
Thank you for voting!
Main circuit board wouldn't allow the compressor to come on
22 of 26 people
found this instruction helpful.
-
Leonard from Keller, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver
Removed old circuit board and replaced with new
Was this helpful?
Thank you for voting!
Fridge Door would not close "automagically"
24 of 33 people
found this instruction helpful.
-
David from Cary, NC
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
I had to remove the fridge door (side by side), which took approximately 10min (most of which was retrieving the right size socket wrench from the garage). With the door removed, I could replace the broken door closing cam and door stop... with 4 screws. Not much to it. Had the door mounted back on in another 5min and that was it. :)
Other Parts Used:
Was this helpful?
Thank you for voting!
Replace ice maker
21 of 28 people
found this instruction helpful.
-
Gary from Glendale, AZ
- Easy
- 15 - 30 mins
-
Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b
... Read more
in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Read less
Was this helpful?
Thank you for voting!
evertthing in frige was freezing
19 of 24 people
found this instruction helpful.
-
justin from brownsville, OH
- Easy
- 15 - 30 mins
-
Screw drivers
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to r
... Read more
emove.
Read less
Was this helpful?
Thank you for voting!
Cracked Housing Mount - water leak
19 of 25 people
found this instruction helpful.
-
Richard from Chandler, AZ
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing a
... Read more
nd reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Read less
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people
found this instruction helpful.
-
Tracy from Yuba City, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
low water flow from in door water dispenser
17 of 20 people
found this instruction helpful.
-
kevin from summerville, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two
... Read more
screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
Read less
Was this helpful?
Thank you for voting!
Frozen water filter and food in fresh food side
16 of 18 people
found this instruction helpful.
-
Herbert from Sunriver, OR
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom.
... Read more
The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.
When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.
Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.
Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.
Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.
Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.
Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.
Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
loss of refrigeration
15 of 17 people
found this instruction helpful.
-
Heather from Pennington, NJ
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering ... Read more the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering ... Read more the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Read less
Was this helpful?
Thank you for voting!
Iced up Freezer compartment in SxS
15 of 18 people
found this instruction helpful.
-
Jamison from Heltonville, IN
- Really Easy
- Less than 15 mins
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice m
... Read more
aker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Read less
Was this helpful?
Thank you for voting!
My 13 yr grandson assisted me on this
15 of 18 people
found this instruction helpful.
-
Sherry from Auburn Hills, MI
- Really Easy
- Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?