The light switch on the refridgerator broke - no light.
36 of 58 people found this instruction helpful.
  • David from Albany, OR
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
Was this helpful?
Thank you for voting!
Evaporator Fan had quit running
25 of 28 people found this instruction helpful.
  • Duane from Piper City, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
After unplugging the fridge, I removed all the phillips head screws from the evaporator fan housing as well as the back cover and the bottom of the freezer compartment (7) in all. After first removing the bottom cover - then the back cover I could access the evaporator fan unit. This was held in place with two hex-head screws that were e asily removed with a nut driver. Then after unplugging the Red, White, and Green wires from the fan I removed it and replaced it with the new one. I did have to break off the two ends of the mounting bracket as described in the instruction sheet since it was too wide. Repeating the above steps in reverse, I had the job done and refridgerator up and running as quiet as could be in less than 15 minutes.
Was this helpful?
Thank you for voting!
Freezer and Fridge wouldnt cool
24 of 25 people found this instruction helpful.
  • Janet from Hillsboro, OR
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people found this instruction helpful.
  • Florentino from Windsor Locks, CT
  • Easy
  • 30 - 60 mins
  • Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people found this instruction helpful.
  • W from Nellysford, VA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people found this instruction helpful.
  • Bob from Hesston, KS
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Was this helpful?
Thank you for voting!
freezer making a squealing sound
17 of 20 people found this instruction helpful.
  • PAUL from Boiling Springs, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First I Removed the racks. Next 3 hex bolts that secured the ice maker. Undid the ponytail wiring. 3 Phillips screws to remove the metal back. unplugged the Evaporator Fan Motor. Replaced the new one. reassembled.
Was this helpful?
Thank you for voting!
compressor didnt turn on
24 of 41 people found this instruction helpful.
  • gerardo from el monte, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
changed the starter connected to the compressor
Was this helpful?
Thank you for voting!
Door not swinging freely and not closing automatically
15 of 18 people found this instruction helpful.
  • Harold from Sun City, CA
  • Really Easy
  • 30 - 60 mins
  • Socket set
replaced lower door closing cams and shim and cleanded and lubricated top and bottom hinge. Took about 30 minutes. Hardest part was unloading the door and finding a place to put all the bottles and stuff. Door works just fine now.
Was this helpful?
Thank you for voting!
Squealing evaporator fan
15 of 18 people found this instruction helpful.
  • JOHN from BEAVER, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplugged the fridge, emptied the freezer, removed the panel screws, removed the fan assembly retaining nuts, slid the spade wire connectors from the tabs, and performed these tasks in reverse to have the fridge up and running like new. I am not an appliance repair person, but I am not intimidated by simple repairs. Your instructions wer e easy to follow, and the cry in the kitchen of "we need a new refrigerator" was silenced for less than $50.00. Thanks!
Was this helpful?
Thank you for voting!
Unit Was Not Self Defrosting
15 of 19 people found this instruction helpful.
  • mary from lodi, NJ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
A very easy job. Heater was broken and needed to be replaced and since the freezer was over 30 years old I also replaced the timer. Now the freezer is good for another 30 years thanks to parts silect and there speedy shipment of my parts
Was this helpful?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people found this instruction helpful.
  • David from Cedarville, OH
  • A Bit Difficult
  • More than 2 hours
  • Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people found this instruction helpful.
  • bill from escondido, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
The refrigerator door made a terrible bang every time it was opened.
13 of 15 people found this instruction helpful.
  • Hank from Seattle, WA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
The hardest part was unloading all the food from the refridgerator door! Once done, pry shroud off top door hinge, remove 3 screws and hinge plate. Lift door off bottom hinge. Remove one screw from bottom of door, remove and discard old lifter cam and spacer. Clean up a bit. Install new spacer and lifter cam. Tighten new screw firml y. Replace the lifter cam and spacer on bottom hinge pin (affixed to refridgerator body) using the same method. Replacing the door is easiest if 2 people do it. One person to lift and steady the door, the other has to lie on the floor and guide the door onto the hinge pin. Replace top hinge plate and screws. Snap shroud back over top hinge plate. Replace food in refridgerator. Close door. Done!
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people found this instruction helpful.
  • David from Arnold, ME
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).