lower pull out drawer handle fastener to freezer was broken on one side.
11 of 12 people found this instruction helpful.
  • David from BENICIA, CA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
I ordered the plastic fastener, that held the handle to the freezer door.
after I received the part I used a screw driver to attach the fastener to the door. Then I placed the handle onto the fastener and bumped the handle with my hand to the left. this attached the handle to the door.
Was this helpful?
Thank you for voting!
Spring on Articulating mullion was broke causing manual shutting of door.
11 of 13 people found this instruction helpful.
  • Todd from EOLIA, MO
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Literally took the two Phillips head screws out of the middle hinge, disconnect the wire, slide old one off. Plug in new plug, slide new one on replace screws. Less than 5 minutes.
Was this helpful?
Thank you for voting!
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
10 of 11 people found this instruction helpful.
  • Kirk E from GRASS VALLEY, CA
  • Easy
  • Less than 15 mins
  • Screw drivers
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I search ed and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.

Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Was this helpful?
Thank you for voting!
Bottom Freezer Handle
9 of 9 people found this instruction helpful.
  • Billy from La Fayette, GA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Broke off the freezer handle of my GE refrigerator, silly horseplay.
Super simple repair, but pricey. Old handle was already off due to being broken. remove handle brackets (that had broken ears) with a Phillips screwdriver. Replace the brackets with same screwdriver, slide new handle into place. Easy.
Was this helpful?
Thank you for voting!
Freezer not getting cold enough to freeze ice cream
8 of 10 people found this instruction helpful.
  • Gary from ROSETO, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I took the advice off of your website about the only thing that will fix
the problem is change the run capacitor. I felt assured that I would
have a working refrigerator freezer after making this change. I was
pretty disheartened when it didn`t solve anything. I was not going to
take the new part back out after the sma ll challenge of putting it in.
The next day I found out how to test the old capacitor and it was still
good. I will just have to eat the $49. I did learn not to take advice from
a website even if it seems like a sure thing
Was this helpful?
Thank you for voting!
No water and no ice being made
6 of 6 people found this instruction helpful.
  • Christopher from BANCROFT, MI
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Wrench (Adjustable)
Checked to make sure water was going to the fridge and it was. Removed the 1st line after the valve and no water was present. Figured the valve was bad. Removed the wires to the old valve and also had to remove the wire harness on the new valve. It wasn't needed. Replaced the valve and installed the old wires. Hooked up the water line and instantly had water. A day later I had a full ice bucket. This part wasn't listed on GE website. But it was on partselect.com.
Was this helpful?
Thank you for voting!
Refrigerator to warm
5 of 5 people found this instruction helpful.
  • Lloyd from PITTSBURG, CA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Was this helpful?
Thank you for voting!
Replace 2 shelves
4 of 4 people found this instruction helpful.
  • Donald A from Hobe Sound, FL
  • Very Easy
  • Less than 15 mins
no brainer took out the old put in the new! approximately 7 seconds total time.
Was this helpful?
Thank you for voting!
No water to door or ice maker
4 of 4 people found this instruction helpful.
  • David from PORT ST LUCIE, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Wrench set
Followed steps found on YouTube. The only missing instruction was to remove the small retaining clip from the water tube inlets to allow you to press the retaining circle down to release the tube
Was this helpful?
Thank you for voting!
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
5 of 7 people found this instruction helpful.
  • Rickey from DUMAS, AR
  • Really Easy
  • 30 - 60 mins
  • Socket set
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugge d it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Was this helpful?
Thank you for voting!
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
4 of 5 people found this instruction helpful.
  • Bert from SAN JOSE, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little ret aining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Was this helpful?
Thank you for voting!
Cheap plastic handle fasteners
4 of 5 people found this instruction helpful.
  • Dan from IOWA CITY, IA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
After ordering these expensive plastic, doomed to break again and again fasteners I had a fella make some on a 3d printer, each one for under 1 cent!!! Not the 7.50 each I paid here.
Was this helpful?
Thank you for voting!
Interior light would not come on when right hand door was open
4 of 5 people found this instruction helpful.
  • brian from CLOQUET, MN
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Remove the screws from the two door pivot covers. Remove the covers and set aside. Remove the screws from the control board; disconnect the electrical connections; remove the door light switch, install door light switch then reinstall everything.
Was this helpful?
Thank you for voting!
Broken door shelf
3 of 3 people found this instruction helpful.
  • laura from ANNA, IL
  • Very Easy
  • Less than 15 mins
Snapped broken one out, snapped new one in. Flawless.
Was this helpful?
Thank you for voting!
Handle kept coming off
3 of 4 people found this instruction helpful.
  • Craig from MANSFIELD, GA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Replaced a clip.
Was this helpful?