Fan in freezer quit
-
Dan from Woodstock, GA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
This was an easy job. First remove the ice maker, if you have one. Mine was mounted with just two screws. Loosen these screws, unplug the power cord at the connector and then lift the ice maker off. Remove the light bulb cover and the light bulb, just so you dont break it. Remove two hex screws and the back cover can be removed. My fan wa
... Read more
s mounted in the middle of a bracket retained between two rubber bushingings. Just push the fan blad of the shaft and pull the motoer out. Dissonect the power cord at the connector. My moter was differant than the replacement on the mounting so with the removial of the two screws on the motor I was able to exchange the upper and lower cast motoer housings. Reverse the assembly process and you good. Mine is running great.
Read less
Was this helpful?
Thank you for voting!
Freezer iced up, fridge section warm
-
Guillermo from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground).
... Read more
I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Read less
Was this helpful?
Thank you for voting!
Freezer was warm
-
Charles from Macomb, MI
- Really Easy
- 30 - 60 mins
-
Screw drivers
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% categor
... Read more
y though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Read less
Was this helpful?
Thank you for voting!
freezer cold, fridge not cold
-
Sam from Marshall, NC
- A Bit Difficult
- More than 2 hours
-
Nutdriver
Removed shelving, and rear panels. Replaced condenser fan and defrost thermostat. Defrost coil ohmed fine. Reassembled and plugged in fridge with thermometers inside. Freezer at 22degrees and fridge at 32 degrees. My first time repairing a fridge. the partselect videos were very helpful.
Was this helpful?
Thank you for voting!
compressor wouldn't start
-
Mike from Kilgore, TX
- Really Easy
- Less than 15 mins
I used a pick to remove the lugs from the old starter. Clicked them right in the new one and it went to woking!!!
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer would not freeze longer than one day. after ten years without problem
-
ronald from deering, NH
- Really Easy
- Less than 15 mins
pulled out freezer, went to floor,reached in next to compressor pulled off clip just like on the video.Pulled off old capacitator took off wire leads.Installed new one. Freezer runs great.Loaded it up with beef pork and venison. No problems.
Was this helpful?
Thank you for voting!
awasome
-
chris from springfield, GA
- Really Easy
- Less than 15 mins
After reading reviews I was not sure but I ordered part on Wensday in the AM and I had the correct part Thursday evening this company rocks thank you by the way i paid for regular shipping I will order again in a heartbeat
Was this helpful?
Thank you for voting!
compressor not running
-
wilson from indialantic, FL
- Really Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
thanks to all of the people who had the same problems I was able to make a quick fix on my fridge. I pulled the back cover off and found the compressor not kicking on so I replaced the start cap. and im back in bussiness.
Was this helpful?
Thank you for voting!
the compressor capacitor overheated
-
Bart from goldsboro, NC
- Really Easy
- Less than 15 mins
-
Screw drivers
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Was this helpful?
Thank you for voting!
refer quit cooling and so did freezer
-
jerry from petaluma, CA
- Really Easy
- Less than 15 mins
I replaced the defrost timer,defrost thermostat,and run cap.as it turned out the compressor went bad. I dont know the model because but the time I got this review I replaced the refer with a knew one . two weeks living out of coolers was so much fun !!!!!!!!
Was this helpful?
Thank you for voting!
not cold enough
-
Gary from Hudson, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
per the video..easy installation....unfortunately the temperature did not improve. We still have a refrigerator temp in the upper freezer.....and a "cooler" in the refrigerator section
Was this helpful?
Thank you for voting!
Frige and freezer not cooling
-
FRANK from BRADENTON, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver
I should have ordered start kit instead of start capacitor. The start cap astir did not fix problem so I ordered kit. Compasator comes as part of kit. Followed enclosed instructions. Cut existing wires and reconnected new wiring. Simple as that. It's a plug in item. Now worried it may be working to good. Freezer down to 10 deg. Watching
... Read more
to see if compressor is running to long. Seems ok lol. Wife hates me now. She wanted new frige.
Read less
Was this helpful?
Thank you for voting!
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
-
BILL from GENOA, WV
- Really Easy
- 15 - 30 mins
-
Nutdriver
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If th
... Read more
e unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Read less
Was this helpful?
Thank you for voting!
Coils not Defrosting and stopped freezing
-
Joseph from Yulee, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this helpful?
Thank you for voting!
won't start repaced the run capacitor didn't solve the problem so I ordered a defrost timer
-
Curtis from Winlock, WA
- Really Easy
- 15 - 30 mins
I watched the videos (they really help) and followed the steps. Everything went smooth with no surprises
Was this helpful?
Thank you for voting!