Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people found this instruction helpful.
  • David from ABINGDON, VA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people found this instruction helpful.
  • DAVE from LOS RANCHOS, NM
  • Very Easy
  • Less than 15 mins
  • Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th e video that was on-line helpful also.
Was this helpful?
Thank you for voting!
Freezer coils kept freezing over.
4 of 6 people found this instruction helpful.
  • Kyle from Porter, OK
  • Really Easy
  • Less than 15 mins
  • Nutdriver
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed th e Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Was this helpful?
Thank you for voting!
freezer colk, refrig warm
2 of 2 people found this instruction helpful.
  • Jeff from GLENDORA, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Followed the instructions provided in your video, took less than 15 minutes and works like new. Thank you for the parts and the advice.
Was this helpful?
Thank you for voting!
Freezer not cooling due to icing up of coil.
2 of 2 people found this instruction helpful.
  • Thomas from GRANBURY, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Was this helpful?
Thank you for voting!
freezer was warm
2 of 2 people found this instruction helpful.
  • Carol from OSHKOSH, WI
  • Easy
  • 30 - 60 mins
  • Screw drivers
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
Was this helpful?
Thank you for voting!
Fridge not cooling
3 of 5 people found this instruction helpful.
  • WESTLEY from HATTIESBURG, MS
  • Easy
  • 15 - 30 mins
  • Nutdriver
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heate r strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
Was this helpful?
Thank you for voting!
Freezer wasn't cooling - compressor not engaging
2 of 2 people found this instruction helpful.
  • Judy from ROYSE CITY, TX
  • Really Easy
  • 30 - 60 mins
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other p arts, but not happy that the actual part I needed was not available - had to use other methods.
Was this helpful?
Thank you for voting!
Coils were freezing up. Defrost cycle not working
2 of 3 people found this instruction helpful.
  • Stirling from FORT WORTH, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Was this helpful?
Thank you for voting!
Fridge quit working.
1 person found this instruction helpful.
  • Bill from Bay City, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench set
A little research told me the hum plus no cooling was either the compressor or the relay. I ordered the new relay and put it in but it didn't fix the problem. I ended up having to buy a new fridge, but it was worth the $30 gamble to see if I could fix it on the cheap and it saved me the money a service call would've cost. Pretty easy i nstallation, just in a tight space on my model.
Was this helpful?
Thank you for voting!
Refrigerator keeps frosting up and not cooling
1 of 2 people found this instruction helpful.
  • Marvin from Pima, AZ
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Refrigerator started frosting up and running all the time.I'd defrost it and it would frost up again in about a week.The timer seems to be work so I just guest it mite be the Defrost Thermostat.I removed the duck in the center and back panel in the freezer compartment defrosted it and switched Thermostats and replaced panel and duck, goi ng to lower compartment of the refrigerator.So far it seems to be working a little more time while tell.
Was this helpful?
Thank you for voting!
Light burned out on the door lid
1 of 3 people found this instruction helpful.
  • Cynthia from Keystone, NE
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a thin screwdriver to lift out the burned out light assembly. Unplugged the old light unit and installed the new one. Plugged in the freezer and the light worked. Easy as pie.
Was this helpful?
Thank you for voting!
Evaporator freezing up. Noticed Ice cream not frozen solid
0 of 1 people found this instruction helpful.
  • Paul from Buffalo, MN
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
Notice ice build up on the panel in front of the evaporator coil. Unplugged freezer and removed evaporator panel. Plugged unit back in and checked fan, coil "snap switch" and heater element, all seemed to check out good. Found defrost timer stuck in the freeze position, causing frost to accumulate over the evaporator. Manually rotated defrost timer to the 30min defrost cycle and system went into defrost. Ordered defrost timer and installed (part arrived in 3 days). Freezer works great again. Too bad I ended up throwing 400 dollars worth of meat away. the fix was very simple. Will definitely use PartSelect again. Thank you.
Was this helpful?
Thank you for voting!
Freezer was not defrosting thus refrigerator was not cooling
  • Wayne T from Galway, NY
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this helpful?
Thank you for voting!
Refrigerator side not cooling (of Side by Side)
  • K from Lakeview, MI
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
Turned off Refrigerator by thermostat switch in Freezer Compartment,(allowing for light to work in freezer). Then removed all food from freezer side,then all shelves & basket drawer. Next, unplugged refrigerator from electrical source. Removed back of inside of the freezer. Located the Thermostat for defrosting cooling coil. Removed and replaced with new part.(Tip-unplugged the wires for the original thermostat, remove from freezer and cut off and splice with connectors provided with new part, it's easier because you're not trying to do this in the narrow space of the freezer). Then attach the thermostat with new bracket and plug thermostat wires back in, replace back panel, shelves, plug in power supply, turn thermostat switch in Freezer to normal setting. Wait for Freezer to cool and replace food. It's currently working like new. BTW I thought I need a defrost time as well...however after I ordered that part and received it, I turned the existing defroster timer manually with a straight ended screwdriver very slowly and it cycled and the defrost rods glowed/functioned just fine. Therefore I didn't replace defrost timer. I'll save the new timer for future repair if needed. All in all it was fairly easy, and I didn't have to buy another fridge. I was really pleased with the service of this website...and the parts arrived very quickly via Fedex. Thanks www.partselect.com ! KJ