My refrigerator stopped cooling and the freezer section stopped freezing
441 of 556 people
found this instruction helpful.
-
garth from forest lake, MN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck le
... Read more
t's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Read less
Was this helpful?
Thank you for voting!
Seven year old condenser fan was making noise when it was running.
199 of 211 people
found this instruction helpful.
-
Josue from Jacksonville, NC
- Really Easy
- Less than 15 mins
-
Screw drivers
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the
... Read more
new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
Read less
Was this helpful?
Thank you for voting!
Sometimes the condenser fan would start causing the refrigerator to overheat.
189 of 228 people
found this instruction helpful.
-
Tom from Franklin, WI
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Read less
Was this helpful?
Thank you for voting!
Broken light switch
82 of 134 people
found this instruction helpful.
-
Randy from Hays, KS
- Really Easy
- 15 - 30 mins
-
Socket set
Took all the screws out of the plastic shroud that encloses the switch .There only four that I needed to remove, were the two in front where the switches that go,they go in horizontally and two in the back with large washers on them that hold the back to the top of the box that go in vertically.The switch was a snap ( make that two snaps
... Read more
) the wiring is almost self explanatory. then it gos back to the way you took it off. OH! and don't forget to turn the light bulb all the way back in to the socket , so the light will work after you take the time to install it yourself.I had the water supply line from under the box to the water dispenser in the door and the total bill on that was one hundred thirty seven and a hand full of change.Don't be afraid to do it yourself the savings is enough on one one item to make several months payments on a new one Randy the "Handy Man'
Read less
Was this helpful?
Thank you for voting!
Fridge made noise and the center post was HOT!
54 of 60 people
found this instruction helpful.
-
David from Jefferson City, MO
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
We have a side-by-side fridge/freezer and we experienced a hot center post (where doors come together) and the fridge made loud noise. Also, the (old) fan motor would start, but then quit, so our issue was the motor.
For me the repair was very easy, but for an unexperienced person it may prove to be difficult. If you must o ... Read more rder a motor/fan, do NOT order the metal fan as a plastic fan comes with the motor. What's strange is the new motor is different than the old one, but it still mounted without any required modifications. I did NOT use the wire harness that came with the motor either as it was different too, but my old one was still good.
Check all of your parts as my fan had a cracked blade, but I used "superglue" and it's fine now.
Fridge stays cold and my wife had to lower the temperature in the fridge as she was blasted by the cold!
For me the repair was very easy, but for an unexperienced person it may prove to be difficult. If you must o ... Read more rder a motor/fan, do NOT order the metal fan as a plastic fan comes with the motor. What's strange is the new motor is different than the old one, but it still mounted without any required modifications. I did NOT use the wire harness that came with the motor either as it was different too, but my old one was still good.
Check all of your parts as my fan had a cracked blade, but I used "superglue" and it's fine now.
Fridge stays cold and my wife had to lower the temperature in the fridge as she was blasted by the cold!
Read less
Was this helpful?
Thank you for voting!
was not making ice
48 of 57 people
found this instruction helpful.
-
Richard from North Wilkesboro, NC
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
diagnosed no water flow over evaporator checked voltage into pump then checked pump with ohm meter ordered pump and installed by removing access cover and water holding assembly installed new pump replaced water holding assembly and access cover and returned icemaker to service all is well
Was this helpful?
Thank you for voting!
old condenser fan motor shaft was loose and it made the spinning fan blades shake and cause noise
40 of 44 people
found this instruction helpful.
-
Christopher from Snow Camp, NC
- Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
The procedure was straightforward. I removed the cardboard backing on the lower back of the refrigerator to expose the fan unit. I then undid the electrical harness at the fan. I then removed the three screws securing the fan motor to the metal bracket. This is the hardest part in that I had to reach through and get to the screws with my
... Read more
small tools. I then removed the old motor and blades and placed the new motor and blades. Again, a bit tricky trying to get the three screws mounted into the bracket...small tools and hands helps. After that I used the electrical harness supplied with the kit to plug into the new motor and I was done.
Read less
Was this helpful?
Thank you for voting!
noisy fan motor
38 of 46 people
found this instruction helpful.
-
robert from nashotah, WI
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Socket set
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, c
... Read more
lose up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Read less
Was this helpful?
Thank you for voting!
Grid Assembly had a broken wire and would not separate the ice sheets into cubes
33 of 37 people
found this instruction helpful.
-
Brad from Bakersfield, CA
- Easy
- 15 - 30 mins
-
Nutdriver
I removed the 2 screws on each side of the grid and disconnected the electrical plugs attached to the grid. I slid the broken unit out. I then carefully slid the new unit in making sure not to pinch any of the electrical wires. I replaced the mounting screws, plugged the 3 connectors back into place and turned the ice maker back on. I ha
... Read more
d ice cubes within a couple of hours
Read less
Was this helpful?
Thank you for voting!
the top wire on the cutting grid broke and thus no longer cut the ice. It sat on the wire until the ice melted, depositing no ice into the bin
25 of 26 people
found this instruction helpful.
-
Sherri from Ada, OK
- A Bit Difficult
- More than 2 hours
-
Pliers, Screw drivers
I removed the cutter grid and unplugged the light bulb and wire heating plug ins. I slid the front cover plate off the cutting grid and loosened the screws on the front of the cutter grid and unthreaded the broken, top grid wire, leaving the bottom wire in place as it was in tact.
I then threaded the new wire through the cutting gri ... Read more d frame starting in the center and threading right and then left. While the threading was not difficult, the wire was easily kinked. The process up to this point was only 15 minutes or so.
Once it was completely threaded, I worked for a couple of hours trying to smooth and straighten the wire so that is was somewhat taut and straight enough to create symetrical ice cubes.
My frustration came in pulling on the wire from the center point to each outside ending point where it was to be wrapped around the screw and the screw tightened back down. The wire was fragile enough that it would break, by the time I was finished I barely had enough wire left to touch the screw let alone hook around the screw.
After 3 or four days of successful opperation, the grid quit cutting again. As I took it apart, it was obvious that the weight of the ice was enough to pull the wire, that was already too short, away from the screw. I refastened it again, but think it is unlikely to hold.
If it won't hold, I would be hard pressed to purchase another wire. I may bite the bullet and purchase the entire grid mechanism with the wires already installed. Even though the cost of the entire grid mechanism is $200 more than the purchase of another wire, it may well be worth the ease of installation!
I then threaded the new wire through the cutting gri ... Read more d frame starting in the center and threading right and then left. While the threading was not difficult, the wire was easily kinked. The process up to this point was only 15 minutes or so.
Once it was completely threaded, I worked for a couple of hours trying to smooth and straighten the wire so that is was somewhat taut and straight enough to create symetrical ice cubes.
My frustration came in pulling on the wire from the center point to each outside ending point where it was to be wrapped around the screw and the screw tightened back down. The wire was fragile enough that it would break, by the time I was finished I barely had enough wire left to touch the screw let alone hook around the screw.
After 3 or four days of successful opperation, the grid quit cutting again. As I took it apart, it was obvious that the weight of the ice was enough to pull the wire, that was already too short, away from the screw. I refastened it again, but think it is unlikely to hold.
If it won't hold, I would be hard pressed to purchase another wire. I may bite the bullet and purchase the entire grid mechanism with the wires already installed. Even though the cost of the entire grid mechanism is $200 more than the purchase of another wire, it may well be worth the ease of installation!
Read less
Was this helpful?
Thank you for voting!
Freezer and Fridge wouldnt cool
24 of 25 people
found this instruction helpful.
-
Janet from Hillsboro, OR
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in
... Read more
the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Read less
Was this helpful?
Thank you for voting!
Ice maker overfilling with ice and would not stop production when full.
26 of 33 people
found this instruction helpful.
-
Ray from Terry, MS
- Very Easy
- 15 - 30 mins
-
Nutdriver
Very easy to replace. Down load the Manual online for a completely operating manual. Thermistor can be tested with an Ohm Meter. Proper values are listed in operating manual.
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people
found this instruction helpful.
-
Florentino from Windsor Locks, CT
- Easy
- 30 - 60 mins
-
Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people
found this instruction helpful.
-
W from Nellysford, VA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns
... Read more
crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Read less
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people
found this instruction helpful.
-
Bob from Hesston, KS
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova
... Read more
l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Read less
Was this helpful?
Thank you for voting!