Water Valve Leaking
2 of 5 people found this instruction helpful.
  • Mark from Dumfries, VA
  • Easy
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench (Adjustable)
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks re installed lower rear cover
Was this helpful?
Thank you for voting!
In-Door Dispenser Didn't Work And Leaked Water
1 of 2 people found this instruction helpful.
  • Jabe from Little Torch Key, FL
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
1. Use skewer to press plastic tabs under control panel, 2. Remove control panel and unplug solenoid, 3. Unscrew dispenser assembly and solenoid screws, 4. Press in tabs on lamp and remove assembly - unplug, 5. Replace lamp assembly, 6. Replace solenoid assembly and fasten scr ews, 7. Replace flapper. 8. Replace other parts in reverse order.
Was this helpful?
Thank you for voting!
ice maker stopped working
1 of 2 people found this instruction helpful.
  • Karen from Gainesville, FL
  • Easy
  • 30 - 60 mins
  • Wrench (Adjustable)
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed t he inlet and back of refrigerator in place.
Was this helpful?
Thank you for voting!
No water going into ice maker
1 of 3 people found this instruction helpful.
  • Bobby A from Del City, OK
  • Easy
  • 15 - 30 mins
  • Nutdriver
Pulled the fridge out from the wall, disconnected the power cord,turned off the water supply,removed the backing that covers the fan/motor and the two way water valve. Removed one screw that holds water valve to back of fridge,removed two water lines. Installed the new water valve , connected water lines and screw, installed back dust cov er, plugged in the 110 cord, turned on the water valve. Within 30 minutes a new tray of ice cubes was ejected into the ice holding box. Mission completed.
Was this helpful?
Thank you for voting!
Ice dispenser chute icing up
1 of 3 people found this instruction helpful.
  • Robert from North Topsail Beach, NC
  • Easy
  • 15 - 30 mins
  • Screw drivers
Replaced dispenser flapper
Was this helpful?
Thank you for voting!
I had a soleniod and the crank assembly to got bad.
2 of 6 people found this instruction helpful.
  • Ronald from Chester, SC
  • Easy
  • 15 - 30 mins
  • Screw drivers
First, I had to remove the face plate where the ice and water was dispensed remove 4 screws holding the electrical circuits, disconnect circuits ,remove 2 screws holding soleniod and one screw holdin crank assembly. repace parts and screws.
Was this helpful?
Thank you for voting!
Ice maker only dispensed crushed ice.
1 of 3 people found this instruction helpful.
  • Richard from THE VILLAGES, FL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Determined that the little door that opens to allow full size cubes to fall was not opening. If you open freezer door, hold door switch in, select cubes and push in the lever that the glass pushes in you should hear the solenoid lift open which opens the little door. Mine was doing nothing. Removed ice bin and then removed icemaker motor /solenoid section from back of freezer by disconnecting two wire harnesses and one screw. Found that solenoid smelled burnt and could see that inside of the solenoid was swollen out of round and burnt. Simple to replace.
Was this helpful?
Thank you for voting!
water kept freezing in tube to icemaker
0 of 1 people found this instruction helpful.
  • percy from rosenberg, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Wrench (Adjustable)
removed backing from the refrigerator then unscrewed the pump from refrigerator unhooked the electrial connections. Then hooked up new pump by connectioning the elctrical then putting water connections back on with the quick connects then plugged refrigetator back in the reinstalled back of refrigerator and slide back into place as simple as 123
Was this helpful?
Thank you for voting!
Water was not filling icemaker.
0 of 1 people found this instruction helpful.
  • Donald from Sugar Hill, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
It was very easy replacement. I was sent a different style that allowed for the water tubes to be pushed in compression wise instead of havinf to screw them on. The water was going ok to the cold water in the door but was not functioning for the ice maker. I had already replaced the ice maker unit due to a couple of missing teeth in the t urn wheel but still could not get the water to fill. The original problem was created by the missing teeth creating a steady flow of water ultimately all over the floor. It took booth units to fix the problem and now the ice maker works as it should. The valve came with the proper connectors and the toughest part of the job was pulling out the frig. Nice to have something work as described and fit perfectly. A simple nut driver or socket was all that was needed for the entire job.
Was this helpful?
Thank you for voting!
leak from duel inlet water valve
0 of 1 people found this instruction helpful.
  • Tom from Forest, VA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Pulled unit away from wall. Removed lower panel. Turned off water and electricity. Removed two nuts holding valve. Disconnected electrial wiring. Cut water lines going into old valve close to the valve so the lines could be reused with new unit. Installed new valve by pressing lines into valve, reconnected electricity. Put two screw s back in. Turned on water and electricity. Works great. No leaks. Results of leaks required hardwood floor to be repaired (sanded and refinished). Stayed away from kitchen for nine (9) days. Need to check for leaks everytime you clean under the refrigerator.
Was this helpful?
Thank you for voting!
Water valve was bad, no power!
0 of 1 people found this instruction helpful.
  • Jeffry from Athens, IL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Wrench (Adjustable)
First I removed the screw holding the valve in place. I then pulled the valve out about 3 inches and disconnected the two wires and water line.
I repaced the old valve with the new valve and performed the steps in reverse order and the ice maker was making ice that night. I however developed a leak and had to have another valve sent. The problem has been solved and all is well.
Parts select has been fast, friendly and helpful through my whole experience. I would like to say thanks for all your courteous help and hopefully this will help others realize the benefit of Parts select to us do-it-ourselfer!.

Thank you!

Jeff Lopian
Athens, Illinois
Was this helpful?
Thank you for voting!
leaking water inlet valve
0 of 1 people found this instruction helpful.
  • Lynn from White Pine, TN
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench (Adjustable)
Changing the valve was easy, remove and replace. The problem came afterwards. After shuting off the water and waiting for the replacement valve, the water line coming in to the icemaker froze solid causing water to spray into the freezer, causing a major leak. After thawing out the line, it still leaked because the water in the freezer ha d frozen up the freezer drain again causing another leak.Bottom line, after replaceing the valve, take a few extra minutes to check or replace the water line coming to the icemaker. That will save a headache later.
Was this helpful?
Thank you for voting!
Ice chute from the ice maker frosted over. Cubes would not dispense
0 of 1 people found this instruction helpful.
  • Dana from Pittstown, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
1. Unplug the fridge
2. Removed the outer facing of the dispenser outside the freezer door. This is fairly easy, better with a tool (plastic scraper) that won't mar the finish.
3. Removed the plastic plate with labels -- water, ice, etc. This is done by sliding a small jewelers screwdriver into the slots on the left, middle and right in back of the plate. These are difficult to see without a flashlight.
4. Removed the four screws in the panel behind this plate.
5. Unpluged the large cable on the left side after the panel is freed.
5. Removed the rubber "dispenser" button. this just pulls off.
6. Remove the panel
7. Lift flapper up and remove. Clips hold this in.
8. Put new flapper in place.
9. Use reverse order to put back together.
Piece of cake. Ice maker no longer frosts up.!!!!
Was this helpful?
Thank you for voting!
We had water leaking all over the floor realized it was coming from our refrigerator.
0 of 1 people found this instruction helpful.
  • Mark from Gilbert, AZ
  • Easy
  • Less than 15 mins
  • Screw drivers
We pulled out our refrigerator and found the leak coming from a valve that controlled the purified water and ice machine. We shut of the water source at our filter system and then removed the part. Looked online and found the part we needed at a great price. Ordered it and installed it when it arrived 3 days later. Easy install and we now have water and ice coming from our refrigerator again- not to mention a clean floor underneath too.
Was this helpful?
Thank you for voting!
Water leaked from body of Valve
0 of 1 people found this instruction helpful.
  • Kevin from Tuscola, IL
  • Easy
  • Less than 15 mins
  • Nutdriver, Wrench set
Turned off water, ordered part based on photo and partial appliance model number (my model number was not listed); removed old part using hand wrench and nutdriver: slid existing retaining nuts up waterlines(left on for furture reuse if needed) and slid lines into "Pex" type connectors and remounted (one screw) valve to refrigerator and t urned on water.

Note: From Part ordered to received was less than 36 hours!